Francisco Montero

Dr. Francisco Montero

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2021 in Journal of Cleaner Production
Verified
Journal Article
Closed access
FMFrancisco Montero
Francisco Montero
RLRavita Lamba
Ravita Lamba
AOAlfonso Ortega
Alfonso Ortega
WJWolfram Jahn
Wolfram Jahn
AGAmador M. Guzmán
Amador M. Guzmán

9 April 2025 in Energies
Verified
Journal Article
Open access
PDF file
FMFrancisco Montero
Francisco Montero
PVPaco Jovanni Vásquez-Carrera
Paco Jovanni Vásquez-Carrera
WHWilliam Armando Hidalgo
William Armando Hidalgo
AAAleph Salvador Acebo
Aleph Salvador Acebo
HCHéctor Calvopiña
Héctor Calvopiña
YFYousra Filali
Yousra Filali
Hybrid photovoltaic (PV) and thermoelectric generator (TEG) systems combine heat and light energy harvesting in a single module by utilizing the entire solar spectrum. This work analyzed the feasibility and performance of a hybrid photovoltaic–thermoelectric generator system with efficient thermal management by integrating heat pipe (HP), radiative cooling (RC), and heat sink (HS) systems. The proposed system effectively reduces the PV operation temperature by evacuating the residual heat used in the TEG system to generate an additional amount of electricity. The remaining heat is evacuated from the TEG’s cold side to the atmosphere using RC and HS systems. This study also analyzed the inclusion of two TEG arrays on both sides of the HP condenser section. This numerical analysis was performed using COMSOL Multiphysics 5.5 software and was validated by previous analysis. The performance was evaluated through an energy and exergy analysis of the TEG and PV systems. Enhancing the thermal management of the hybrid PV-TEG system can increase energy production by 2.4% compared to a PV system operating under the same ambient and solar radiation conditions. Furthermore, if the proposed system includes a second array of TEG modules, the energy production increases by 5.8% compared to the PV system. The exergy analysis shows that the enhancement in the thermal management of the PV operating temperature decreases the thermal exergy efficiency of the proposed system but increases the electricity exergy efficiency. Including TEG modules on both sides of the condenser section of the HP shows the system’s best thermal and electrical performance. These results may be helpful for the optimal design of realistic solar-driven hybrid systems for globally deserted locations.

7 September 2023 in Frontiers in Energy Research
Verified
Journal Article
Open access
FMFrancisco Montero
Francisco Montero
RLRavita Lamba
Ravita Lamba
SSSarveshwar Singh
Sarveshwar Singh
WJWolfram Jahn
Wolfram Jahn
WCWei-Hsin Chen
Wei-Hsin Chen
In this paper, energy and exergy analysis of a bidirectional solar thermoelectric generator (STEG) coupled to a latent heat storage and cooling system (LHSCS) has been carried out. The effect of various parameters of LHSCS on energy and exergy efficiencies of STEG have been analysed under climatic conditions of Chile’s Atacama Desert. It is found that the most relevant design parameter to improve the energy and exergy efficiencies of the thermoelectric generator (TEG) is the container insulation, followed by heat sink at the TEG hot side, fin thickness and the aspect ratio of the container. The results showed that an optimally designed insulation container can improve the energy and exergy efficiencies of LHSCS by 30% and 200%, respectively, and the TEG conversion efficiency by 30% during nighttime. Further, inclusion of heat sink at TEG hot side during reverse operation of TEG at night can improve the TEG efficiency by 20%. The optimal fin thickness can improve the TEG conversion efficiency by 20% during the night and LHSCS energy and exergy efficiencies by 30% and 23%, respectively. The container geometry should have higher aspect ratios. This study may help in optimal design of LHSCS for solar energy conversion applications in the desert locations.


9 July 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
HCHéctor Calvopiña
Héctor Calvopiña
FMFrancisco Paredes Mera
Francisco Paredes Mera
DJDavid Eduardo Balseca Jaramillo
David Eduardo Balseca Jaramillo
FCFidel Castro
Fidel Castro
BVBenjamín Velasteguí
Benjamín Velasteguí
FMFrancisco Montero
Francisco Montero
The heat transfer and fluid mechanics analysis in agitated vessels is usually performed using the Dittus-Boelter correlation. In this study, we propose the analysis of an agitated vessel with a draft tube through the analysis of dimensionless numbers correlations. The heat transfer and fluid mechanics simulation was conducted using ANSYS Fluent software. The simulation used the Sliding Mesh approach and the SST k-ω turbulent model to capture the vessel's fluid flow and heat transfer phenomena. A grid independence study was conducted by varying the number of time steps to obtain an appropriate time step size for the simulation. The convective heat transfer coefficient, as indicated by the mean values of the Nusselt number, was calculated. The local values along the radial coordinate of the heat transfer surface were also determined. These results provide insights into the distribution of heat transfer rates within the vessel, which can help optimize process efficiency and equipment design. The simulation results were analyzed by varying the c and m coefficients in the Nusselt correlation presented as Nu= c Rem Pr1/3. Furthermore, correlations describing the mean Nusselt number at the bottom and wall of the vessel are presented and compared with existing literature, contributing to advancing knowledge in this field.