Yishan Zhong

Mr. Yishan Zhong


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 May 2026 in Sensors
Verified
Journal Article
Open access
PDF file
SDSeth Donahue
Seth Donahue
JPJ.D. Peiffer
J.D. Peiffer
RRR. Tyler Richardson
R. Tyler Richardson
YZYishan Zhong
Yishan Zhong
STShaun Q. Y. Tan
Shaun Q. Y. Tan
RCRoss Chafetz
Ross Chafetz
This study validates a clinically accessible approach for quantifying the Upper Extremity Reachable Workspace (UERW) using monocular AI-driven Markerless Motion Capture (MMC). Objective validation of such techniques for clinically oriented tasks is essential to support their adoption in clinical motion analysis. Nine adults without impairments performed the standardized UERW task, reaching targets distributed across a virtual sphere centered on the torso and displayed via VR headset. Movements were simultaneously captured with a marker-based system and eight FLIR cameras; monocular analysis was applied to two videos representing frontal and offset camera configurations. Agreement was assessed by comparing the percentage workspacereached across six of eight workspace octants between the systems. The frontal camera demonstrated strong agreement with the marker-based reference (mean bias: 0.61±0.12% reachspace per octant), whereas the offset view underestimated workspace reached −5.66±0.45%. Depth-related errors in the frontal configuration were confined to posterior octants, whereas the offset view introduced inaccuracies in both contralateral and posterior octants. These findings support the feasibility of a frontal monocular camera for UERW assessment, particularly for anterior workspace evaluation. While posterior accuracy remains limited by depth estimation and anatomical occlusion errors, the overall results demonstrate clinical potential for practical, monocular-camera assessments.

7 August 2025 in arXiv
Verified
Preprint
Open access
PDF file
MCMatthew Chen
Matthew Chen
MNMicky Nnamdi
Micky Nnamdi
JSJustin Shao
Justin Shao
AHAndrew Hornback
Andrew Hornback
HHHongyun Huang
Hongyun Huang
MWMay Dongmei Wang
May Dongmei Wang
Foundation models for electroencephalography (EEG) signals have recently demonstrated success in learning generalized representations of EEGs, outperforming specialized models in various downstream tasks. However, many of these models lack transparency in their pretraining dynamics and offer limited insight into how well EEG information is preserved within their embeddings. For successful clinical integration, EEG foundation models must ensure transparency in pretraining, downstream fine-tuning, and the interpretability of learned representations. Current approaches primarily operate in the temporal domain, overlooking advancements in digital signal processing that enable the extraction of deterministic and traceable features, such as wavelet-based representations. We propose MENDR (Manifold Explainable Neural Data Representations), a filter bank-based EEG foundation model built on a novel Riemannian Manifold Transformer architecture to resolve these issues. MENDR learns symmetric positive definite matrix embeddings of EEG signals and is pretrained on a large corpus comprising over 4,000 hours of EEG data, decomposed via discrete wavelet packet transforms into multi-resolution coefficients. MENDR significantly enhances interpretability by visualizing symmetric positive definite embeddings as geometric ellipsoids and supports accurate reconstruction of EEG signals from learned embeddings. Evaluations across multiple clinical EEG tasks demonstrate that MENDR achieves near state-of-the-art performance with substantially fewer parameters, underscoring its potential for efficient, interpretable, and clinically applicable EEG analysis.

13 February 2026 in arXiv
Verified
Preprint
Open access
PDF file
SDSeth Donahue
Seth Donahue
JPJ. D. Peiffer
J. D. Peiffer
RRR. Tyler Richardson
R. Tyler Richardson
YZYishan Zhong
Yishan Zhong
STShaun Q. Y. Tan
Shaun Q. Y. Tan
RCRoss Chafetz
Ross Chafetz
To validate a clinically accessible approach for quantifying the Upper Extremity Reachable Workspace (UERW) using a single (monocular) camera and Artificial Intelligence (AI)-driven Markerless Motion Capture (MMC) for biomechanical analysis. Objective assessment and validation of these techniques for specific clinically oriented tasks are crucial for their adoption in clinical motion analysis. AI-driven monocular MMC reduces the barriers to adoption in the clinic and has the potential to reduce the overhead for analysis of this common clinical assessment. Nine adult participants with no impairments performed the standardized UERW task, which entails reaching targets distributed across a virtual sphere centered on the torso, with targets displayed in a VR headset. Movements were simultaneously captured using a marker-based motion capture system and a set of eight FLIR cameras. We performed monocular video analysis on two of these video camera views to compare a frontal and offset camera configurations. The frontal camera orientation demonstrated strong agreement with the marker-based reference, exhibiting a minimal mean bias of $0.61 \pm 0.12$ \% reachspace reached per octanct (mean $\pm$ standard deviation). In contrast, the offset camera view underestimated the percent workspace reached ($-5.66 \pm 0.45$ \% reachspace reached). Conclusion: The findings support the feasibility of a frontal monocular camera configuration for UERW assessment, particularly for anterior workspace evaluation where agreement with marker-based motion capture was highest. The overall performance demonstrates clinical potential for practical, single-camera assessments. This study provides the first validation of monocular MMC system for the assessment of the UERW task. By reducing technical complexity, this approach enables broader implementation of quantitative upper extremity mobility assessment.