Alan Argento

Prof. Dr. Alan Argento


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2012 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
WKWonsuk Kim
Wonsuk Kim
AAAlan Argento
Alan Argento
FRFrank W. Rozsa
Frank W. Rozsa
KMKaitlyn Mallett
Kaitlyn Mallett
The constitutive behavior of bovine scleral and corneal tissues is measured in tension and compression, at quasi-static and moderate strain rates. Experiments are conducted at strain rates up to about 50 strain per second by a pneumatic testing system developed to overcome noise and measurement difficulties associated with the time dependent test of low impedance materials. Results for the tissues at room and the natural bovine body temperatures are similar and indicate that ocular tissue exhibits nonlinear stiffening for increasing strain rates, a phenomena termed rate hardening. For example, at a tensile strain rate of 29/s, corneal tissue is found to develop 10 times the stress that it does quasi-statically at the same strain. Thus, conventional constitutive models will grossly underpredict stresses occurring in the corneo-scleral shell due to moderate dynamic events. This has implication to the accuracy of ocular injury models, the study of the stress field in the corneo-scleral shell for glaucoma research and tonometry measurements. The measured data at various strain rates is represented using the general framework of a constitutive model that has been used to represent biological tissue mechanical data. Here it is extended to represent the measured data of the ocular tissues over the range of tested strain rates. Its form allows for straightforward incorporation in various numerical codes. The experimental and analytical methods developed here are felt to be applicable to the test of human ocular tissue.

2 May 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
XMXiaofei Man
Xiaofei Man
EAElizabeth Arroyo
Elizabeth Arroyo
MDMartha Dunbar
Martha Dunbar
DRDavid M Reed
David M Reed
NSNeil Shah
Neil Shah
AAAlan Argento
Alan Argento
There is extensive knowledge on the relationship of posterior scleral biomechanics and intraocular pressure (IOP) load on glaucomatous optic neuropathy; however, the role for biomechanical influence of the perilimbal scleral tissue on the aqueous humor drainage pathway, including the distal venous outflow system, and IOP regulation is not fully understood. The purpose of this work is to study the outflow characteristics of perfused porcine eyes relative to the biomechanical properties of the perilimbal sclera, the posterior sclera and the cornea. Enucleated porcine eyes from eleven different animals were perfused with surrogate aqueous at two fixed flow rates while monitoring their IOP. After perfusion, mechanical stress-strain and relaxation tests were conducted on specimens of perilimbal sclera, posterior sclera, and cornea from the same perfused eyes. Statistical analysis of the data demonstrated a strong correlation between increased tangent modulus of the perilimbal sclera tissues and increased perfusion IOP (R2 = 0.74, p = 0.0006 at lower flow rate and R2 = 0.71, p = 0.0011 at higher flow rate). In contrast, there were no significant correlations between IOP and the tangent modulus of the other tissues (Posterior sclera: R2 = 0.17 at lower flow rate and R2 = 0.30 at higher flow rate; cornea: R2 = 0.02 at lower flow rate and R2<0.01 at higher flow rate) nor the viscoelastic properties of any tissue (R2 ≤ 0.08 in all cases). Additionally, the correlation occurred for IOP and not net outflow facility (R2 ≤ 0.12 in all cases). These results provide new evidence that IOP in perfused porcine eyes is strongly influenced by the tangent modulus, sometimes called the tissue stiffness, of the most anterior portion of the sclera, i.e. the limbus.

21 November 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
YTYufeng Tian
Yufeng Tian
WKWonsuk Kim
Wonsuk Kim
AKAlper Kiziltas
Alper Kiziltas
DMDeborah Mielewski
Deborah Mielewski
AAAlan Argento
Alan Argento
A damping model is developed based on the mechanism of interfacial interaction in nanoscale particle reinforced composites. The model includes the elasticity of the materials and the effects of interfacial adhesion hysteresis. Specific results are given for the case of bio-based PA610 polyamide reinforced by nanocrystalline cellulose (CNC), based on a previous study that showed this composite possesses very high damping. The presence of hydrogen bonding at the interface between the particle and matrix and the large interfacial area due to the filler’s nano size are shown to be the main causes of the high damping enhancement. The influence of other parameters, such as interfacial distance and stiffness of the matrix materials are also discussed. The modeling work can be used as a guide in designing composites with good damping properties.

1 July 2014 in Journal of Sound and Vibration
Verified
Journal Article
Closed access
WKWonsuk Kim
Wonsuk Kim
AAAlan Argento
Alan Argento
PMPravansu S. Mohanty
Pravansu S. Mohanty

22 May 2014 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
AAAlan Argento
Alan Argento
WKWonsuk Kim
Wonsuk Kim
FRFrank W. Rozsa
Frank W. Rozsa
KDKori L. DeBolt
Kori L. DeBolt
SZSophia Zikanova
Sophia Zikanova
JRJulia R. Richards
Julia R. Richards
Ocular tissue properties have been widely studied in tension and compression for humans and a variety of animals. However, direct shear testing of the tissues of the sclera appear to be absent from the literature even though modeling, analyses, and anatomical studies have indicated that shear may play a role in the etiology of primary open angle glaucoma (POAG). In this work, the mechanical behavior of bovine scleral tissue in shear has been studied in both out-of-plane and in-plane modes of deformation. Stress–strain and relaxation tests were conducted on tissue specimens at controlled temperature and hydration focusing on trends related to specimen location and orientation. There was generally found to be no significant effect of specimen orientation and angular location in the globe on shear stiffness in both modes. The in-plane response, which is the primary load carrying mode, was found to be substantially stiffer than the out-of-plane mode. Also, within the in-plane studies, tissue further from the optic nerve was stiffer than the near tissue. The viscosity coefficient of the tissue varied insignificantly with distance from the optic nerve, but overall was much higher in-plane than out-of-plane.

11 November 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
LNLinyu Ni
Linyu Ni
JRJohn Riesterer
John Riesterer
HWHuaizhou Wang
Huaizhou Wang
LBLayla Berry
Layla Berry
KBKara Blackburn
Kara Blackburn
AAAlan Argento
Alan Argento
A method motivated by the eye’s aqueous veins is described for the imaging and strain calculation within soft biological tissues. A challenge to the investigation of the biomechanics of the aqueous vein—perilimbal sclera tissue complex is resolution of tissue deformations as a function of intraocular pressure and the subsequent calculation of strain (a normalized measure of deformation). The method involves perfusion of the eye with a contrast agent during conduction of non-invasive, optical resolution photoacoustic microscopy. This imaging technique permits three-dimensional displacement measurements of tracked points on the inner walls of the veins which are used in a finite element model to determine the corresponding strains. The methods are validated against two standard strain measurement methods. Representative porcine globe perfusion experiments are presented that demonstrate the power of the method to determine complex strain fields in the veins dependent on intraocular pressure as well as vein anatomy. In these cases, veins are observed to move radially outward during increases in intraocular pressure and to possess significant spatial strain variation, possibly influenced by their branching patterns. To the authors’ knowledge, these are the only such quantitative, data driven, calculations of the aqueous vein strains available in the open literature.