Biomimetic micro-hexagonal-textured surfaces have sparked interest for their application in fields that demand high friction and adhesion, such as micro-robotics and biomedicine. Despite extensive research conducted on this specific microstructure, its friction behavior against soft counterfaces remains a topic that has not been fully investigated yet. This study examines how micro-hexagon textures behave when they come into contact with engineered and biological materials like gelatin and chicken skin in dry and wet conditions. The results show clearly that under dry contact conditions, flat surfaces generate higher friction compared to hexagon micropattern surfaces. Under wet conditions, hexagon micropattern surfaces generate higher friction compared to flat surfaces. In wet conditions specifically, the static coefficient of friction is up to 13 times greater than that of a flat specimen against glass, up to 11 times greater against gelatin, and up to 6 times greater against chicken skin. For the dynamic coefficient of friction, the patterned surface demonstrates a maximum increase by a factor of 28 against glass, 11 against gelatin, and 5 against chicken skin. These results further develop our knowledge of these hexagon micropattern surfaces and pave the way for their utilization in future technological advancements in which soft and wet counterfaces are to be considered, such as in biomedical applications that can benefit from increased friction in wet conditions for better control and stability.
Myopia patients wear rigid gas-permeable contact lenses during the day to achieve normal vision, but they might feel uncomfortable, since they are made of hard materials that can cause inappropriate friction and adhesion. These forces affect the biological tissues of the cornea and eyelid. In this study, an in vitro rigid gas-permeable contact lens friction testing method was established to mimic the friction between the eyelid and the rigid contact lens. The lens was rubbed against a gelatin membrane to investigate the tribological properties of artificial tear, saline, and two kinds of care solutions using a dedicated experimental setup. The viscosity, pH value, and surface tension of each lubricant was also analyzed. The friction coefficient of the artificial tear solution was the highest: 0.18 for its static friction and 0.09 for its dynamic friction. In contrast, polysaccharide-containing care solution demonstrated the lowest friction coefficient. The viscosity of artificial tear solutions ranged from 0.97 ± 00 to 1.15 ± 0.16 mPa·s, when the shear rate was increased from 19.2 to 192 1/s, while it ranged from 2.26 ± 1.12 to 2.91 ± 0.00 for polysaccharide-containing care solution. Although the physical–chemical properties of various lubricants could not explain the distinct tribological outcomes, the in vitro tribological testing method for rigid gas-permeable lenses was successfully established in this study.