Gareth G. Jones

Dr. Gareth G. Jones

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2016 in The Bone & Joint Journal
Verified
Journal Article
Open access
PDF file
GJGareth G. Jones
Gareth G. Jones
MKM. Kotti
M. Kotti
AWA. V. Wiik
A. V. Wiik
RCR. Collins
R. Collins
MBM. J. Brevadt
M. J. Brevadt
JCJustin Cobb
Justin Cobb
Aims: To compare the gait of unicompartmental knee arthroplasty (UKA) and total knee arthroplasty (TKA) patients with healthy controls, using a machine-learning approach. Patients and Methods: 145 participants (121 healthy controls, 12 patients with cruciate-retaining TKA, and 12 with mobile-bearing medial UKA) were recruited. The TKA and UKA patients were a minimum of 12 months post-operative, and matched for pattern and severity of arthrosis, age, and body mass index. Participants walked on an instrumented treadmill until their maximum walking speed was reached. Temporospatial gait parameters, and vertical ground reaction force data, were captured at each speed. Oxford knee scores (OKS) were also collected. An ensemble of trees algorithm was used to analyse the data: 27 gait variables were used to train classification trees for each speed, with a binary output prediction of whether these variables were derived from a UKA or TKA patient. Healthy control gait data was then tested by the decision trees at each speed and a final classification (UKA or TKA) reached for each subject in a majority voting manner over all gait cycles and speeds. Top walking speed was also recorded. Results: 92% of the healthy controls were classified by the decision tree as a UKA, 5% as a TKA, and 3% were unclassified. There was no significant difference in OKS between the UKA and TKA patients (p = 0.077). Top walking speed in TKA patients (1.6 m/s; 1.3 to 2.1) was significantly lower than that of both the UKA group (2.2 m/s; 1.8 to 2.7) and healthy controls (2.2 m/s; 1.5 to 2.7; p < 0.001). Conclusion: UKA results in a more physiological gait compared with TKA, and a higher top walking speed. This difference in function was not detected by the OKS. Cite this article: Bone Joint J 2016;98-B(10 Suppl B):16–21.

1 January 2012 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
AHAmanda J P Hutchinson
Amanda J P Hutchinson
SBSimon Ball
Simon Ball
JAJeremy C H Andrews
Jeremy C H Andrews
GJGareth G. Jones
Gareth G. Jones
Low back pain is a common musculoskeletal disorder defined as pain and soreness, muscle tension, or stiffness in the lumbosacral area of the spine which does not have a specific cause. Low back pain results in high health costs and incapacity to work causing an economic burden to society. The optimal management of non-specific low back pain appears to be undecided. Recently published guidelines support the use of acupuncture for treating non-specific low back pain and it has become a popular alternative treatment modality for patients with low back pain.

1 April 2012 in Gait & Posture
Verified
Journal Article
Open access
LALouis Atallah
Louis Atallah
AWAnatole Wiik
Anatole Wiik
GJGareth G. Jones
Gareth G. Jones
BLBenny Lo
Benny Lo
JCJustin Cobb
Justin Cobb
GYGuang-Zhong Yang
Guang-Zhong Yang
A force-plate instrumented treadmill (Hp Cosmos Gaitway) was used to validate the use of a miniaturised lightweight ear-worn sensor (7.4 g) for gait monitoring. Thirty-four healthy subjects were asked to progress up to their maximum walking speed on the treadmill (starting at 5 km/h, with 0.5 km increments). The sensor houses a 3D accelerometer which measures medio-lateral (ML), vertical (VT) and anterior-posterior (AP) acceleration. Maximum signal ranges and zero crossings were derived from accelerometer signals per axis, having corrected for head motion and signal noise. The maximal force, measured by the instrumented treadmill correlated best with a combination of VT and AP acceleration (R-squared = 0.36, p = 0), and combined VT, ML, and AP acceleration (R-squared=0.36, p = 0). Weight-acceptance peak force and impulse values also correlated well with VT and AP acceleration (Weight acceptance: R-squared = 0.35, p = 0, Impulse: 0.26, p = 0), and combined VT, ML, and AP acceleration (Weight acceptance: R-squared = 0.35, p = 0, Impulse: 0.26, p=0). Zero crossing features on the ML axis provided an accurate prediction of the gait-cycle, with a mean difference of 0.03s (-0.01, 0.05 confidence intervals).

1 January 2017 in World Journal of Orthopedics
Verified
Journal Article
Open access
AWAnatole Vilhelm Wiik
Anatole Vilhelm Wiik
AAAdeel Aqil
Adeel Aqil
MBMads Brevadt
Mads Brevadt
GJGareth G. Jones
Gareth G. Jones
JCJustin Cobb
Justin Cobb
Abnormal ground reaction forces lead to a general decline in gait speed in knee osteoarthritis patients

1 May 2018 in EFORT Open Reviews
Verified
Journal Article
Open access
GJGareth G. Jones
Gareth G. Jones
MJMartin Jaere
Martin Jaere
SCSusannah Clarke
Susannah Clarke
JCJustin Cobb
Justin Cobb
High tibial osteotomy (HTO) is a relatively conservative surgical option in the management of medial knee pain. Thus far, the outcomes have been variable, and apparently worse than the arthroplasty alternatives when judged using conventional metrics, owing in large part to uncertainty around the extent of the correction planned and achieved. This review paper introduces the concept of detailed 3D planning of the procedure, and describes the 3D printing technology that enables the plan to be performed. The different ways that the osteotomy can be undertaken, and the varying guide designs that enable accurate registration are discussed and described. The system accuracy is reported. In keeping with other assistive technologies, 3D printing enables the surgeon to achieve a preoperative plan with a degree of accuracy that is not possible using conventional instruments. With the advent of low dose CT, it has been possible to confirm that the procedure has been undertaken accurately too. HTO is the ‘ultimate’ personal intervention: the amount of correction needed for optimal offloading is not yet completely understood. For the athletic person with early medial joint line overload who still runs and enjoys life, HTO using 3D printing is an attractive option. The clinical effectiveness remains unproven. Cite this article: EFORT Open Rev 2018;3 DOI: 10.1302/2058-5241.3.170075.

1 June 2015 in International Journal of Surgery
Verified
Journal Article
Closed access
RKRichard M. Kwasnicki
Richard M. Kwasnicki
RARaza Ali
Raza Ali
SJStevan J. Jordan
Stevan J. Jordan
LALouis Atallah
Louis Atallah
JLJulian J.H. Leong
Julian J.H. Leong
ADAra Darzi
Ara Darzi
Total knee replacement currently lacks robust indications and objective follow-up metrics. Patients and healthcare staff are under-equipped to optimise outcomes. This study aims to investigate the feasibility of using an ear-worn motion sensor (e-AR, Imperial College London) to conduct objective, home-based mobility assessments in the peri-operative setting. Fourteen patients on the waiting list for knee replacement, and 15 healthy subjects, were recruited. Pre-operatively, and at 1, 3, 6, 12 and 24 weeks post-operatively, patients underwent functional mobility testing (Timed Up and Go), knee examination (including range of motion), and an activity protocol whilst wearing the e-AR sensor. Features extracted from sensor motion data were used to assess patient performance and predict patients' recovery phase. Sensor-derived peri-operative mobility trends correlated with clinical measures in several activities, allowing functional recovery of individual subjects to be profiled and compared, including the detection of a complication. Sensor data features enabled classification of subjects into normal, pre-operative and 24-week post-operative groups with 89% (median) accuracy. Classification accuracy was reduced to 69% when including all time intervals. This study demonstrates a novel, objective method of assessing peri-operative mobility, which could be used to supplement surgical decision-making and facilitate community-based follow-up.