A composite interferometric all-fiber sensor based on an asymmetric misaligned tapered multimode (ASTM) fiber configuration has been designed and investigated. This optical fiber sensor combines the asymmetric staggered taper (AST) structure, single-mode multimode single-mode (SMS) optical fiber and optical fiber bitaper (OFB) structure during preparation. The ASTM-OFB allows for efficient measuring of strains and temperature changes compared to conventional SMS fiber optic architecture. The experimental measurement results show that this new ASTM-OFB fiber optic sensor has two obvious resonance peaks near 1500 nm and 1580 nm, and its strain sensitivity is -37.85 pm/με and -71.92 pm/με respectively, which is about 42 times higher than that of the conventional SMS sensor; the temperature sensitivities in the two resonance peaks are 25.23 pm/°C and 26.47 pm/°C separately. The ASTM-OFB fiber optic sensors measure strain and temperature changes simultaneously with a temperature-strain crosstalk sensitivity of only 0.36 με/°C; its ASTM and OFB structures are prepared by common optical fiber fusion splicing mechanism, with a simple structure, controllable processing parameters and cost-effective.
This article presents a long-period fiber-grating sensor based on a congruent quasi-helical structure (CQH-LPFG) with the two-parameter measurement of both temperature and curvature. The CQH-LPFG sensor was manufactured using a high-frequency CO2 laser, and an innovative quasi-helical structure was introduced into the two-parameter measurement of the temperature and curvature of the optical fiber sensor with excellent results. The experiment and analysis demonstrate that the curvature sensitivities of the three resonance peaks in the 1440 nm to 1540 nm transmission spectrum were 11.88 nm/m−1, 8.05 nm/m−1, and 11.11 nm/m−1, and the curvature varied ranging from 0.156 m−1 to 0.494 m−1. The three resonance peaks showed temperature responsivities of 29.87 pm/°C, 24.65 pm/°C, and 36.85 pm/°C, respectively, and the linear fit was of excellent quality. In the case of measuring both curvature and temperature changes simultaneously, the resonant peak wavelength of the CQH-LPFG sensor was demodulated through matrix analysis, with dip A and dip C providing superior simultaneous measurements. These features make it a promising candidate for applications such as engineering machinery and the health inspection of buildings.
TiO2@CNTs nanocomposite was synthetized by a hydrothermal method at 453 K, using titanium tetrachloride as a precursor and nitrified CNTs as a support. The crystal phase, morphology, microstructure and element distribution of the sample were characterized by X-ray diffraction (XRD), high-resolution transmission electron microscope (TEM), and scanning transmission electron microscopy (STEM-Mapping). The photocatalytic activity of the sample was measured by degrading methyl orange under UV illumination. The results showed that the titania particles in the shape of regular polygon decorate on the outer surface of CNTs evenly, and their sizes were about 7-20 nm. Moreover, photocatalytic activity of the nanocomposite was better than that of P25 Degussa and nitrated CNTs followed the apparent pseudo-first-order rate law. These results point out that synergistic effect exists between the titania and the carbon nanotubes in the nanocomposite.