Esther E. García-Carpintero

Dr. Esther E. García-Carpintero

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

15 October 2022 in Journal of Orthopaedics and Traumatology
Verified
Journal Article
Open access
PDF file
SLSetefilla Luengo-Matos
Setefilla Luengo-Matos
LSLuis María Sánchez-Gómez
Luis María Sánchez-Gómez
AHAna Isabel Hijas-Gómez
Ana Isabel Hijas-Gómez
EGEsther E. García-Carpintero
Esther E. García-Carpintero
RBRafael Ballesteros-Massó
Rafael Ballesteros-Massó
Mª del Mar Polo de SantosMª del Mar Polo de Santos
Mª del Mar Polo de Santos
Background: Robotic surgery (RS) may offer benefits compared with freehand/conventional surgery (FS) in the treatment of patients with spinal disease. The aim of this study was to evaluate the efficacy and safety of RS versus FS in spinal fusion. Methods: A systematic review and meta-analysis was performed. Data analysis and risk of bias assessment were analysed using REVMAN V5.3. Results: We found 11 randomised clinical trials involving 817 patients (FS: 408, RS: 409). The main diagnosis was degenerative spine disease. SpineAssist, Renaissance (Mazor Robotics), Tianji Robot and TiRobot robots (TINAVI Medical Technologies) were used. Pedicle screw placement within the safety zone (grades A + B according to the Gertzbein and Robbins scale) ranged from 93% to 100% in FS versus 85–100% in RS (relative risk 1.01, 95% CI 1.00–1.03, p = 0.14). Regarding intervention time, the meta-analysis showed a mean difference (MD) of 6.45 min (95% CI −13.59 to 26.49, p = 0.53). Mean hospital stay was MD of −0.36 days (95% CI −1.03 to 0.31, p = 0.30) with no differences between groups. Contradictory results were found regarding fluoroscopy time, although there seems to be a lower radiation dose in RS versus FS (p < 0.05). Regarding safety, the studies included surgical revision frequency. Conclusions: No conclusive results were found suggesting that there are benefits in using RS over FS for spinal fusion. Further research with adequate patient selection, robot type and quality-of-life variables is needed. Level of evidence: level 1.

4 April 2026 in Discover Medicine
Verified
Journal Article
Open access
CSCarlos Sanchez-Piedra
Carlos Sanchez-Piedra
ACAntonio Pujol-De Castro
Antonio Pujol-De Castro
LPLucia Pedrosa-Pérez
Lucia Pedrosa-Pérez
EGEsther E. García-Carpintero
Esther E. García-Carpintero

3 December 2021 in International Journal of Technology Assessment in Health Care
Verified
Journal Article
Open access
PDF file
Mª del Mar Polo de SantosMª del Mar Polo de Santos
Mª del Mar Polo de Santos
SLSetefilla Luengo-Matos
Setefilla Luengo-Matos
AHAna Isabel Hijas-Gómez
Ana Isabel Hijas-Gómez
EGEsther E. García-Carpintero
Esther E. García-Carpintero
LSLuis María Sánchez-Gómez
Luis María Sánchez-Gómez
Introduction Robotic surgery (RS) can offer benefits compared to freehand surgery (FS) in the treatment of patients with spinal diseases. The aim of this study was to assess efficacy and safety of RS versus FS in spinal fusion. The outcomes considered were accuracy in the placement of pedicle screws, surgical times, hospital stay, exposure to radiation, and complications. Methods A systematic review and meta-analysis were performed by researchers at the Instituto de Salud Carlos III (ISCIII). Studies published until June 2019 in the English, Spanish, or French languages were retrieved. The data analyses and risk of bias assessments were undertaken using RevMan 5.3. Results Eight randomized controlled trials including 610 patients (RS: 308, FS: 302) were found. The mean age of the patients ranged from 56 to 68 years in the FS group and from 55 to 68 years in the RS group. The percentage of women included ranged from 46 to 73 percent undergoing FS and from 33 to 70 percent undergoing RS. The main diagnosis was degenerative spine disease. The number of screws implanted ranged from 22 to 584 for FS and 23 to 532 for RS. The robots used were the SpineAssist and Renaissance Guidance System (Mazor Robotics, Ltd) and the TiRobot® Orthopaedic Robotic System (Beijing Tinavi Medical Technologies Co., Ltd). Pedicle screw placement within the safety zone (Grades A and B on the Gertzbein and Robbins scale) ranged from 93 to 100 percent in FS and from 85 to 100 percent in RS (relative risk 1.0, 95% confidence interval [CI] 0.99–1.03; p = 0.36) (I2=75%; p = 0.0005). Regarding intervention time, the meta-analysis showed a mean difference (MD) of 15.2 minutes (95% CI 5.35–25.05; p = 0.002) (I2 = 0%; p = 0.39) in favor of FS. The MD in hospital stay was 0.36 days (95% CI -1.03–0.31; p = 0.30) (I2 = 62%; p = 0.07), which was not statistically significant. Contradictory results were found for fluoroscopy time, although RS was associated with a lower radiation dose than FS (p < 0.05). In relation to safety, studies only reported on rates of surgical revision, which ranged from 0 to 2 after FS and from 0 to 10 after RS. The risk or bias was unclear in most studies. Conclusions We found no conclusive results suggesting benefits for spinal fusion using RS compared with FS. Further research with adequate selection of patients, type of robot, and comparator is needed.

1 December 2010 in Revista Iberoamericana de Ciencia Tecnología y Sociedad
Verified
Journal Article
Open access
PDF file
LPLuis Manuel Plaza
Luis Manuel Plaza
EGEsther E. García-Carpintero
Esther E. García-Carpintero
Este trabajo tiene el propósito de analizar las actividades de cooperación en el ámbito tecnológico entre España y Argentina, a la luz del análisis de las patentes argentinas y, entre ellas, las que surgen de la colaboración con España. El análisis se encuadra, así, en el marco más amplio del estudio de las políticas de ciencia, tecnología e innovación de ambos países, así como de los vínculos de cooperación entre ellos. Para tal fin, se han consultado las bases de datos de la United States Patents & Trademark Office (USPTO) y la European Patent Database (EPO), recabando información para el período 2000-2009. Los resultados del estudio revelan que, pese a que existe cooperación científica entre Argentina y España, las acciones bilaterales con posible proyección de mercado que se han emprendido en los últimos años no han redundado en la generación de patentes. Sin embargo, esos lazos de cooperación pueden servir para la identificación futura de espacios de actuación y la puesta en marcha de iniciativas de carácter tecnológico-empresarial de interés común.

20 March 2025 in Revista española de Documentación Científica
Verified
Journal Article
Open access
Daniela De FilippoDaniela De Filippo
Daniela De Filippo
EGEsther E. García-Carpintero
Esther E. García-Carpintero