Background: Pulmonary function testing by barometric whole-body plethysmography (BWBP) is a long-established and well-accepted, non-invasive investigative procedure in cats. Hypothesis/Objectives: To evaluate, if different acclimatization times influence the measurement parameters of BWBP in healthy adult cats. Animals: 48 healthy adult cats. Methods: In the prospective observational study, healthy cats were placed in a measuring chamber and BWBP was performed over 30 minutes. Parameters obtained during the three measurement units of 10 minutes each (T1, T2 and T3) were compared. Results: All measurement parameters except for tidal volume per body weight changed significantly (p<0.05) over the three time periods. From T1-T2, the parameters minute volume per body weight (p<0.001), peak inspiratory flow per body weight (p<0.001), peak expiratory flow per body weight (p = 0.002), pause (p = 0.03), enhanced pause (p = 0.03) and quotient of peak expiratory flow divided by expiratory flow at end expiratory volume plus 50% tidal volume (p = 0.03) changed significantly. From the time interval T2-T3, only respiratory rate (p = 0.02), inspiratory time (p = 0.02), expiratory time (p = 0.04), and relaxation time (p = 0.01) changed significantly. All measurement parameters except for tidal volume per body weight changed significantly (p<0.05) between T1 and T3. Age had a significant influence on all parameters except for peak expiratory flow per body weight and peak inspiratory flow per body weight. The parameters were not influenced by sex. Conclusion and clinical importance: All measurement parameters except tidal volume per body weight were significantly affected by acclimatization time. Controlling for age and sex, there was still a significant influence of acclimatization time on all parameters except for tidal volume per body weight. Standardization of the acclimatization time for future studies would be appropriate in order to maintain comparability.
Shamonda virus (SHAV), which has recently emerged in Central Europe and has caused disease in numerous cattle herds, was detected in brain tissue from two horses that showed clinical signs, including neurological disorder, and underwent pathological examination. The horses reportedly exhibited seizure-like episodes (Horse A) as well as fever and ataxia (Horse B). In both horses, severe lymphohistiocytic meningoencephalitis with hemorrhages was observed in various parts of the central nervous system (CNS), while outside the CNS no abnormalities were found. The virus genome could be detected by RT-qPCR in all examined parts of the CNS of both horses. In a postmortem cerebrospinal fluid sample of one horse, the virus could only be detected with a very low genome load; however, postmortem contamination cannot be completely ruled out. Consistent with the histological findings, no SHAV genome was detected in either the blood or organs outside the CNS. Postmortem, CNS material—especially brainstem tissue—is suitable for detection of histological lesions and virus genomes via RT-qPCR, while intravital diagnostics of a SHAV infection in horses exhibiting neurological signs is at the moment only possible to a very limited extent. The epidemiological role of horses in the SHAV outbreak is currently unclear.
Barometric whole-body plethysmography (BWBP) is considered to be a particularly gentle method of assessing lung function in cats. However, there have been no studies to date investigating the stress experienced by cats during measurements. The prospective study included 48 healthy adult cats. Each cat was measured in the plethysmographic chamber for a total of 30 min and stress levels were determined every 10 min using a stress ethogram. At the beginning of measurements, 75% of cats were assessed as tense. Over the three time periods, a significant (p < 0.001) reduction in the total stress score was observed. In addition, all measurement parameters correlated significantly with the stress score, with the exception of enhanced pause and tidal volume. It can therefore be assumed that cats will initially experience stress during examination in the plethysmographic chamber, but stress will decrease significantly over time. As the stress level correlates with many measurement parameters, this should be taken into account when interpreting the results.
The first detection of the Shamonda virus in Central Europe occurred in mid-June 2026. Direct detection of the virus in blood or cerebrospinal fluid from living horses has not yet been reliably achieved. Serological examinations could therefore be crucial for future diagnostics. This study aimed to determine whether clinically healthy horses develop antibodies against viruses of the simbu serogroup and at what point the first positive antibody titers can be detected. To this end, blood sera from eleven clinically healthy horses based in southern Germany were examined retrospectively at three different time points between June and September 2026. Serological testing was performed using the ID Screen® Schmallenberg virus Multi-species ELISA kit; Innovative Diagnostics, Grabels, France. The results showed that all horses were seronegative or doubtful (one horse) in June (time point 1) and seronegative in July 2026 (time point 2). All eleven horses tested positive for antibodies in August or September (time point 3). There was a significant increase in antibody titers between time point 1 and time point 3, as well as between time point 2 and time point 3. The study found that even clinically healthy horses had been exposed to the pathogen and developed antibodies. Therefore, a positive antibody titer is not necessarily associated with clinical disease.