Intracranial pressure (ICP) monitoring is a staple of neurocritical care. The most commonly used current methods of monitoring in the acute setting include fluid-based systems, implantable transducers and Doppler ultrasonography. It is well established that management of elevated ICP is critical for clinical outcomes. However, numerous studies show that current methods of ICP monitoring cannot reliably define the limit of the brain’s intrinsic compensatory capacity to manage increases in pressure, which would allow for proactive ICP management. Current work in the field hopes to address this gap by harnessing live-streaming ICP pressure-wave data and a multimodal integration with other physiologic measures. Additionally, there is continued development of non-invasive ICP monitoring methods for use in specific clinical scenarios.
16 October 2020 in Journal of Neurological Surgery Part B: Skull Base
Objectives Cerebrospinal fluid (CSF) leaks are a possible complication in patients with skull base fractures (SBFs). The widely cited incidence of CSF leaks is 10 to 30% in SBF patients; however, this estimate is based only on a few outdated studies. A recent report found CSF leaks in <2% SBF patients, suggesting the incidence may be lower now. To investigate this, we report here our institutional series. Design This study is a retrospective chart review. Setting The study was conducted at two major academic medical centers (2000–2018). Participants Adult patients with SBF were included in this study. Main Outcome Measures Variables included age, gender, CSF leak within 90 days, management regimen, meningitis within 90 days, and 1-year mortality. Results Among 4,944 patients with SBF, 199 (4%) developed a CSF leak. SBF incidence was positively correlated with year of clinical presentation (r-squared 0.78, p < 0.001). Among CSF leaks, 42% were conservatively managed, 52% were treated with lumbar drain, and 7% required surgical repair. Meningitis developed in 28% CSF leak patients. The 1-year mortality for all SBF patients was 11%, for patients with CSF leaks was 12%, and for patients with meningitis was 16%. Conclusion In the largest institutional review of SBF patients in the 21st century, we found CSF leak incidence to be 4%. This is lower than the widely cited range of 10 to 30%. Nevertheless, morbidity and mortality associated with this complication remains clinically significant, and SBF patients should continue to be monitored for CSF leaks. We provide here our institutional treatment algorithm for these patients that may help to inform the treatment strategy at other institutions.
For the past three decades, neurosurgeons have utilized cranial neuro-navigation systems, bringing millimetric accuracy to operating rooms worldwide. These systems require an operating room team, anesthesia, and, most critically, cranial fixation. As a result, treatments for acute neurosurgical conditions, performed urgently in emergency rooms or intensive care units on awake and non-immobilized patients, have not benefited from traditional neuro-navigation. These emergent procedures are performed freehand, guided only by anatomical landmarks with no navigation, resulting in inaccurate catheter placement and neurological deficits. A rapidly deployable image-guidance technology that offers highly accurate, real-time registration and is capable of tracking awake, moving patients is needed to improve patient safety. The Zeta Cranial Navigation System is currently the only non-fiducial-based, FDA-approved neuro-navigation device that performs real-time registration and continuous patient tracking. To assess this system’s performance, we performed registration and tracking of phantoms and human cadaver heads during controlled motions and various adverse surgical test conditions. As a result, we obtained millimetric or sub-millimetric target and surface registration accuracy. This rapid and accurate frameless neuro-navigation system for mobile subjects can enhance bedside procedure safety and expand the range of interventions performed with high levels of accuracy outside of an operating room.
1 December 2015 in Journal of Clinical Neuroscience