Alexandros PAtrianakos

Dr. Alexandros PAtrianakos

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in Hellenic Journal of Cardiology
Verified
Journal Article
Open access
APAlexandros PAtrianakos
Alexandros PAtrianakos
AZA.A. Zacharaki
A.A. Zacharaki
ESE.I. Skalidis
E.I. Skalidis
MHM.I. Hamilos
M.I. Hamilos
FPF.I. Parthenakis
F.I. Parthenakis
PVP.E. Vardas
P.E. Vardas
As structural heart disease interventions continue to evolve to a sophisticated level, accurate and reliable imaging is required for pre-procedural selection of cases, intra-procedural guidance, post-procedural evaluation, and long-term follow-up of patients. Traditionally, cardiovascular procedures in the catheterization laboratory are guided by fluoroscopy and angiography. Advances in echocardiography can overcome most limitations of conventional imaging modalities and provide successful completion of each step of any catheter-based treatment. Echocardiography's unique characteristics rendered it the ideal technique for percutaneous catheter-based procedures. The purpose of this review is to demonstrate the use of the most common and up-to-date echocardiographic techniques in recent non-coronary percutaneous interventional procedures, underlining its inevitable and growing role, as well as illustrating areas of weakness and limitations, and to provide future perspectives.

1 March 2022 in Hellenic Journal of Cardiology
Verified
Journal Article
Open access
Nikolaos KadoglouNikolaos Kadoglou
Nikolaos Kadoglou
CPConstantinos Hristou Papadopoulos
Constantinos Hristou Papadopoulos
KPKonstantinos G. Papadopoulos
Konstantinos G. Papadopoulos
SKStefanos Karagiannis
Stefanos Karagiannis
IKIlias Karabinos
Ilias Karabinos
PNPetros Nihoyannopoulos
Petros Nihoyannopoulos
Stress echocardiography (SE) is a well-established and valid technique, widely-used for the diagnostic evaluation of patients with ischemic and non-ischemic cardiac diseases. This statement of the Echocardiography Working Group of the Hellenic Society of Cardiology summarizes the consensus of the writing group regarding the applications of SE, based on the expertise of their members and on a critical review of current medical literature. The main objectives of the consensus document include a comprehensive review of SE methodology and training, focusing on the preparation, the protocols used and the analysis of the SE images and an updated, evidence-based knowledge about SE applications on ischemic and non-ischemic heart diseases, such as in cardiomyopathies, heart failure and valvular heart disease.

1 March 2015 in Echo Research & Practice
Verified
Journal Article
Open access
PDF file
APAlexandros PAtrianakos
Alexandros PAtrianakos
AZAggeliki A. Zacharaki
Aggeliki A. Zacharaki
AKAntonios Kalogerakis
Antonios Kalogerakis
GSGeorgios Solidakis
Georgios Solidakis
FPFragiskos I. Parthenakis
Fragiskos I. Parthenakis
PVPanos E. Vardas
Panos E. Vardas
To compare the peak global longitudinal myocardial strain (PGLS) and peak segmental longitudinal myocardial strain (PSLS) values by speckle-tracking echocardiography (STE) obtained using two different echocardiography devices. STE is an emerging quantitative ultrasound technique that allows an accurate evaluation of global and segmental myocardial function. However, there is a lack of standardization of the acquired data among different manufacturers. Sixty-three subjects, mean age 56.2±10.4 years, underwent complete echocardiographic studies with two different devices (Philips IE33 and General Electric VIVID E9) performed by the same operator. Thirty-one of them had known cardiac disease, with estimated left ventricular ejection fraction <50%, while 32 were free of any cardiovascular disease (control subjects). All images were digitally stored and analyzed using off-line post processing with QLAB 9 and EchoPAC 11 Software packages. PSLS and PGLS were calculated. A strong relationship between QLAB and EchoPAC was found for PGLS (r=0.91, P<0.001), PSLS-4 chamber (CH; r=0.79, P<0.001), PSLS-2CH (r=0.73, P<0.001), and PSLS-3CH (r=0.78, P<0.001) QLAB. Bland–Altman analysis showed absolute differences vs average of −0.16, −0.37, −0.21, and −0.16 for PGLS, PSLS-4CH, PSLS-2CH, and PSLS-apical long-axis views respectively. Segmental analysis showed a good agreement between the apical segments, whereas poor correlations were found for the basal segments. Receiver operating characteristic curve analysis showed that cutoff values for PGLS of −17.5 and −17.75% with Philips or GE systems gave a sensitivity and specificity of 93.5 and 87.5%, and 90 and 87.5%, respectively, in the discrimination of the patients from the controls. Both Philips and GE echo stations were found to give comparable results for PGLS, with approximately the same cutoff values, suggesting that their PGLS results may be interchangeable.

27 January 2009 in European Heart Journal - Cardiovascular Imaging
Verified
Journal Article
Closed access
APAlexandros PAtrianakos
Alexandros PAtrianakos
FPF. I. Parthenakis
F. I. Parthenakis
DKD. Karakitsos
D. Karakitsos
ENE. Nyktari
E. Nyktari
PVP. E. Vardas
P. E. Vardas
Patients with heart failure (HF) show abnormal arterial stiffening. We examined 60 patients (52.1 +/- 12, 8 years) with non-ischaemic dilated cardiomyopathy (NIDC), New York Heart Association II-III, in sinus rhythm, left ventricular ejection fraction 30.1 +/- 8.6%, and 44 normals. All subjects underwent an echocardiographic study and a cardiopulmonary exercise test. We evaluated the segmental proximal aorta (AO) pulse wave velocity (PWV) in the region of aortic arch with a new echo-method: from the suprasternal view, the distance between ascending and descending AO was measured with two-dimensional ultrasound, and the aortic flow wave transit time (TT) was measured with pulsed-wave Doppler. Pulse wave velocity was calculated as aortic distance/TT. Patients showed increased PWV (7.4 +/- 2.9 vs. 4.8 +/- 1.1 m/s, P < 0.001), compared with controls. Patients with advanced left ventricular (LV) (restrictive or pseudo-normal filling pattern) diastolic dysfunction showed increased PWV (8.6 +/- 2.6 vs. 6.6 +/- 2.9 m/s, P = 0.01) and reduced peak and predicted (for age, sex, and body mass) VO(2) (both P < 0.001), compared with those with mild diastolic dysfunction (delayed relaxation filling pattern). Pulse wave velocity was significantly correlated with the LV mass (r = 0.32, P = 0.01), the peak spectral tissue Doppler imaging systolic wave (r = -0.34, P = 0.006), the LV diastolic filling pattern (r = 0.42, P = 0.001), and the peak (r = -0.47, P < 0.001) and predicted VO(2) (r = -0.579, P < 0.001). Patients with NIDC showed increased proximal aortic stiffness, which relates to LV systolic and diastolic function and exercise capacity. The echocardiographic assessment of the regional aorta PWV seems to be clinically important.

15 March 2021 in Genes
Verified
Journal Article
Open access
PDF file
Maria E. MarketouMaria E. Marketou
Maria E. Marketou
JKJoanna Kontaraki
Joanna Kontaraki
APAlexandros PAtrianakos
Alexandros PAtrianakos
GKGeorge Kochiadakis
George Kochiadakis
IAIoannis Anastasiou
Ioannis Anastasiou
FPFragiskos Parthenakis
Fragiskos Parthenakis
Background: microRNAs (miRs) have emerged as important modulators of cardiovascular development and disease. Our aim was to determine whether cardiac-related miRs such as miR-21-5p and miR-1-3p were differentially expressed in acute viral myocarditis and whether any of them was related with the extent of myocardial damage and left ventricular dysfunction. Methods: We enrolled 40 patients with acute viral myocarditis. Blood samples were taken on admission and miRs expression levels in peripheral blood mononuclear cells were quantified by real-time reverse transcription polymerase chain reaction. Results: miR-21-5p, miR-1-3p were significantly elevated in acute myocarditis. miR-21-5p levels showed a strong correlation with global longitudinal strain (r = 0.71, p < 0.01), while miR-1-3p had significant correlations with troponin I (r = 0.79, p < 0.01). Conclusions: The expression of miR-21-5p and miR-1-3p in peripheral blood is increased in acute viral myocarditis, and this increase is correlated with myocardial damage and indicative of left ventricular systolic dysfunction in these patients.

1 September 2008 in Echocardiography
Verified
Journal Article
Closed access
PDF file
APAlexandros PAtrianakos
Alexandros PAtrianakos
FPFrangiskos I. Parthenakis
Frangiskos I. Parthenakis
ENEva G. Nyktari
Eva G. Nyktari
PVPanos E. Vardas
Panos E. Vardas