Background: Less invasive surfactant administration (LISA) is associated with better outcomes than InSurE (Intubation-Surfactant administration-Extubation). Video-laryngoscopy (VL) facilitates intubation in neonates, however safety and cost-effectiveness of VL-assisted LISA have not been evaluated. Methods: We compared the outcomes of infants receiving VL-assisted LISA (n = 67) with a historical cohort of infants who received InSurE (n = 52). Secondary aims were to evaluate safety and cost-effectiveness. Results: VL-assisted LISA was associated with reduced duration of non-invasive ventilation (NIV), reduced duration of oxygen therapy, reduced composite days on NIV and mechanical ventilation (MV), and shorter NICU stay with lower hospital costs for infants ≥29 weeks GA, compared to InSurE. In the VL-assisted LISA group, 66% of the tracheal catheters were placed on the first attempt and 16% of infants displayed desaturation during placement. Conclusion: In infants ≥29 weeks GA, VL-assisted LISA reduced exposure to NIV, oxygen, NIV and MV combined, length of stay, and cost of care compared to InSurE.
Background: Preterm infants are at risk for bronchopulmonary dysplasia (BPD) due to prolonged respiratory support. Studies have described differences in the regional distribution of lung ventilation (non-dependent (NDL) vs. dependent (DL)). The aim of this study was to use LUS to compare regional distribution of pulmonary edema and atelectasis in infants with evolving BPD. Methods: We prospectively performed LUS in premature infants with evolving BPD. On each side, three lung areas (NDL/anterior, lateral, and DL/posterior) were examined for the presence of pulmonary edema and atelectasis. Pulmonary edema scores were assigned based on the number of B-lines, and atelectasis scores were assigned based on the presence/absence of atelectasis. Results: 38 premature infants were enrolled. The NDL showed more pulmonary edema and atelectasis compared to the DL (p = 0.003, p = 0.049, respectively) and compared to the lateral lung (p =< 0.001, p = 0.004, respectively). There was no difference between the lateral and DL (p = 0.188, p = 0.156, respectively). There was no difference between the right and the left lung (p = 0.223, p = 0.656, respectively). Conclusions: In this cohort of preterm infants with evolving BPD, lung disease was unevenly distributed, with more pulmonary edema and atelectasis in the NDL regions compared to the DL or lateral regions.
Objectives: Patent ductus arteriosus (PDA) is the most common cardiovascular finding in preterm neonates, yet assessment of hemodynamic significance relies on echocardiography, which is intrusive and provides only single-point-in-time data. Photoplethysmography (PPG) may offer a continuous, non-invasive alternative. We quantified changes in automated PPG indices—pulse transit time in the hand and foot (PTT-h, PTT-f), foot-to-hand time delay (f-hTD), and relative pulse amplitude in the hand and foot (rAM-h, rAM-f)—following transcatheter PDA closure (TCPC) in preterm infants and correlated these changes with echocardiographic stroke volume.Study Design: A prospective, single-center cohort study was conducted in a Level IV NICU (January 2022–March 2024). Very low birth weight infants (<1500 g) with hemodynamically significant PDA scheduled for TCPC were enrolled. PPG waveforms were recorded using standard pulse oximeter probes connected to a custom device that automatically calculated indices from 20-pulse sequences. Recordings and echocardiograms were obtained before and 24–48 hours after TCPC.Results: Eighteen infants were enrolled (median gestational age 25.2 weeks; birth weight 755 g). Stroke volume decreased significantly after TCPC (3.56 vs. 2.58 mL, p=0.042). PTT-h increased from 32 to 48 msec (p3 mL) with 89% sensitivity and 80% specificity.Conclusions: PPG indices change significantly after TCPC, and PTT-h correlates well with SV. PPG may complement echocardiography in assessing PDA hemodynamic significance.