Aims and objectives: The pandemic of COVID-19 is evolving worldwide, and it is associated with high mortality and morbidity. There is a growing need to discuss the elements of a coordinated strategy to control the spread and mitigate the severity of COVID-19. H1N1 and Streptococcus pneumonia vaccines are available. The current analysis was performed to analyze the severity of COVID-19 and influenza (H1N1) vaccination in adults ≥ 65. Also, to correlate the lower respiratory tract infections (LRIs), and influenza attributable to the lower respiratory tract infections' incidence with Covid-19 mortality. Evolutionarily influenza is close in resemblance to SARS-CoV-2 viruses and shares some common epitopes and mechanisms. Methods: Recent influenza vaccination data of 34 countries from OECD and other publications were correlated with COVID-19 mortality from worldometer data. LRIs attributable to influenza and streptococcus pneumonia were correlated with COVID-19 mortality. Specifically, influenza-attributable LRI incidence data of various countries (n = 182) was correlated with COVID-19 death by linear regression and receiver operating characteristic (ROC) curve analyzes. In a logistic regression model, population density and influenza LRI incidence were correlated with COVID-19 mortality. Results: There is a correlation between COVID-19-related mortality, morbidity, and case incidence and the status of influenza vaccination, which appears protective. The tendency of correlation is increasingly highlighted as the pandemic is evolving. In countries where influenza immunization is less common, there is a correlation between LRIs and influenza attributable to LRI incidence and COVID-19 severity, which is beneficial. ROC curve showed an area under the curve of 0.86 (CI 0.78 to 0.944, P < 0.0001) to predict COVID-19 mortality >150/million and a decreasing trend of influenza LRI episodes. To predict COVID-19 mortality of >200/million population, the odds ratio for influenza incidence/100,000 was −1.86 (CI −2.75 to −0.96, P < 0.0001). To predict the parameter Covid-19 mortality/influenza LRI episodes*1000>1000, the influenza parameter had an odd's ratio of −3.83 (CI −5.98 to −1.67), and an AUC of 0.94. Conclusion: Influenza (H1N1) vaccination can be used as an interim measure to mitigate the severity of COVID-19 in the general population. In appropriate high-risk circumstances, Streptococcus pneumonia vaccination would also be an adjunct strategy, especially in countries with a lower incidence of LRIs.
A novel stent was designed for the treatment of coronary bifurcation lesion, and it was investigated for its performance by finite element analysis. This study was performed in search of a novel method of treatment of bifurcation lesion with provisional stenting. A bifurcation model was created with the proximal vessel of 3.2 mm diameter, and the distal vessel after the side branch (2.3 mm) was 2.7 mm. A novel stent was designed with connection links that had a profile of a tram. Laser cutting and shape setting of the stent was performed, and thereafter it was crimped and deployed over a balloon. The contact pressure, stresses on the arterial wall, stresses on the stent, the maximal principal log strain of the main artery and the side-branch were studied. The study was performed in Abaqus, Simulia. The stresses on the main branch and the distal branch were minimally increased after deployment of this novel stent. The side branch was preserved, and the stresses on the side branch were lesser; and at the confluence of bifurcation on either side of the side branch origin the von-Mises stress was marginally increased. The stresses and strain at the bifurcation were significantly lesser than the stresses and strain of the currently existing techniques used in the treatment of bifurcation lesions though the study was primarily focused only on the utility of the new technology. There is a potential for a novel Tram-stent method in the treatment of coronary bifurcation lesions.
A novel large self-expanding endovascular stent was designed with strut thickness of 70 μm × 70 μm width. The method was developed and investigated to identify a novel simpler technique in aortic aneurysm therapy. Stage 1 analysis was performed after deploying it in a virtual aneurysm model of 6 cm wide × 6 cm long fusiform hyper-elastic anisotropic design. At cell width of 9 mm, there was no buckling or migration of the stent at 180 Hg. Radial force of the stents was estimated after parametric variations. In stage 2 analysis, a prototype 300 μm × 150 μm stent with a cell width of 9 mm was chosen, and it was evaluated similarly after embedding in the aortic wall, and also with a tissue overgrowth of 1 mm over the stent. The 300/150 μm stent reduced the peak wall stress by 70% in the aneurysm and 50% reduction in compliance after embedding. Stage 3 analysis was performed to study the efficacy of stents with struts (thickness/width) 70/70, 180/100 and 300/150 μm after embedding and tissue overgrowth. The adjacent wall stresses were very minimal in stents with 180/100 and 70/70 μm struts after embedding. There is potential for a novel stent method in aortic aneurysm therapy.
Vascular endothelial growth factor is well known for its angiogenesis potential. The study was performed to determine the possible pro-angiogenic role of magnetic nanoparticles coupled to VEGF in vitro and their capacity to cross an endothelial monolayer. This novel treatment technique for angiogenesis could be potentially useful for therapeutic purposes using magnetic nanoparticles. Magnetic nanoparticles (MN) were synthesized and were conjugated with the vascular endothelial growth factor. The particles were tested in vitro in a 2D to 3D culture system. MN was seeded in different positions in relation to an HUVEC spheroid to assess a preferential migration. To evaluate the MN capacity to cross the endothelial barrier, a confluent monolayer of HUVEC cells was seeded on top of a collagen gel. MN was placed in dissolution on the cell culture media, and the MN position was determined by confocal microscopy for 24 h. HUVEC spheroids were able to generate a preferential sprouting depending on the MN position. Meanwhile, there was random migration when the MN’s were placed all over the collagen gel and no sprouting when no MN was added. The trans-endothelial migration capacity of the MN was observed after 20 h in culture in the absence of external stimuli. Here we show in vitro angiogenesis following the distribution of the MN conjugated with growth factors. These nanoparticles could be controlled with a magnet to place them in the ischemic area of interest and speed up vascular recovery. Also, MN has potentials to cross endothelium, opening the doors to a possible intravascular and extravascular treatment.
1 February 2018 in Revista Portuguesa de Cardiologia
Difficulty in engaging with guide catheters is not uncommon in acute emergencies. We aimed to evaluate the use of Cordis® INFINITI diagnostic catheters to perform angioplasty in patients in whom the coronaries cannot be engaged using standard guide catheters. In 34 cases of acute coronary syndrome, when difficulty in engagement with two standard guide catheters was encountered with reasonable manipulations, angioplasty was performed using diagnostic catheters. In total, 40 stents were placed by this technique. Pushability and trackability, distal tip flexion and three-point bending tests were performed to evaluate the performance of the guide and diagnostic catheters. Angioplasty was performed easily in a setting where it would have been very difficult to perform. Coronary dissection occurred in one patient, treated by a stent. The stent and dilatation balloons were easily passed through the diagnostic catheters. Pressure tracings were clearly preserved with certain stent delivery systems, and at angioplasty, although there was slightly reduced opacification of the respective artery, the coronary anatomy was sufficiently visualized to perform angioplasty. No periprocedural target lesion complications were seen in any cases. Pushability and trackability tests showed good force transmission along a tortuous path with diagnostic catheters, and balanced force-displacement curves from three-point bending tests and distal tip softness tests. Angioplasty with stenting can be performed safely through 6F Cordis® infiniti diagnostic catheters when difficulty in engaging guide catheters is encountered.
1 February 2017 in JMV-Journal de Médecine Vasculaire