Ryosuke Miki

Ms. Ryosuke Miki

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 January 2025 in Radiation
Verified
Journal Article
Open access
PDF file
RMRyosuke Miki
Ryosuke Miki
TTTatsuya Tsuchitani
Tatsuya Tsuchitani
YTYoshiyuki Takahashi
Yoshiyuki Takahashi
KKKazuhiro Kitajima
Kazuhiro Kitajima
YTYasuyuki Takahashi
Yasuyuki Takahashi
The image quality index for whole-body bone scintigraphy has traditionally relied on the total count (Total-C) with a threshold of ≥1.5 million counts (MC). However, Total-C measurements are susceptible to variability owing to urine retention. This study aimed to develop a skeletal count (Skel-C)-based index, focusing exclusively on bone regions, to improve the accuracy of image analysis in bone scintigraphy. To determine the optimal Skel-C-based threshold, Skel-C thresholds were set at 0.9, 1.0, 1.1, and 1.2 MC, and Total-C thresholds were set at 1.75, 2.0, and 2.25 MC. Patients were then categorized based on whether their values were above or below these thresholds. The group including all cases was defined as the Total-C 1.5 high group. Sensitivity and specificity were calculated for each group, and receiver operating characteristic analyses and statistical evaluations were conducted. The specificity of the bone scintigraphy image analysis program in the Skel-C < 0.9 MC group was significantly lower than that in the Skel-C ≥ 0.9 MC and Total-C 1.5 high groups. The decrease in specificity was evident only with Skel-C and was not identified based on Total-C levels. These findings highlight the importance of achieving Skel-C ≥ 0.9 MC and suggest that Total-C alone is insufficient for reliable image assessment.

10 December 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
RMRyosuke Miki
Ryosuke Miki
TTTatsuya Tsuchitani
Tatsuya Tsuchitani
YTYoshiyuki Takahashi
Yoshiyuki Takahashi
KKKazuhiro Kitajima
Kazuhiro Kitajima
YTYasuyuki Takahashi
Yasuyuki Takahashi
The image quality index for whole-body bone scintigraphy has traditionally relied on the total count (Total-C) with a threshold of ≥1.5 mc. However, Total-C measurements are susceptible to variability owing to urine retention. This study aimed to develop a skeletal count (Skel-C)-based index, focusing exclusively on bone regions, to improve the accuracy of image analysis in bone scintigraphy. All cases included herein were Total-C≥1.5 mc. Thresholds were set for Skel-C (0.9–1.2 mc) and Total-C (1.75–2.25 mc); patients were grouped according to whether they were above or below these thresholds. The group including all cases was defined as the Total-C 1.5 high group. Sensitivity and specificity were calculated for each group, and receiver operating characteristic analyses and statistical evaluations were conducted. The specificity of the Skel-C < 0.9 mc group was significantly lower than that of the Skel-C ≥ 0.9 mc group and the Total-C 1.5 high group. These findings highlight the importance of achieving Skel-C ≥ 0.9 mc and suggest that Total-C alone is insufficient for reliable image assessment.