Daniela Guiducci

Dr. Daniela Guiducci

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 October 2024 in American Journal of Orthodontics and Dentofacial Orthopedics
Verified
Journal Article
Open access
FPFederica Pellitteri
Federica Pellitteri
PAPaolo Albertini
Paolo Albertini
LBLuca Brucculeri
Luca Brucculeri
FCFrancesca Cremonini
Francesca Cremonini
DGDaniela Guiducci
Daniela Guiducci
LLLuca Lombardo
Luca Lombardo
The aim was to compare the soft tissue changes in pretreatment and posttreatment facial scans of patients who had undergone various orthopedic treatments vs a control group of untreated growing patients. Facial scans were performed before (T0) and after (T1) orthopedic treatment in 15 patients prescribed rapid palatal expander (RPE), 15 cervical headgear (HG), and 15 facemasks (FM), as well as 6 months apart in 15 untreated growing patients. After best-fit scan alignment using Geometric Control X software (3D Systems Inc, Rock Hill, SC), a 3-dimensional (3D) analysis of soft tissue changes was performed, comparing 3D reference points (total 22) and 8 areas on T0 and T1 scans. Kruskal-Wallis nonparametric tests and pairwise comparison with Bonferroni's correction were applied to identify any statistically significant differences among groups (P <0.05). All analyses were conducted with SPSS software (version 28; IBM, Armonk, NY). At T1, reduced soft tissue projection was found at the nose and upper lip in the HG group, the lower lip in the HG and RPE groups, and the chin in the FM and RPE groups. The RPE group displayed a statistically significant increase in facial divergence, confirmed by gnathion position (RPE vs FM [P = 0.018] and RPE vs control [P = 0.046]), as well as an increase in the soft tissue projection of both cheeks (left cheek in range of 1-2 mm [P = 0.030] and range of 0 to -1 mm [P = 0.022]; right cheek in range of 1-2 mm [P = 0.003] and range -1 to -2 mm [P = 0.001]). There were no clinically significant differences among groups in mandibular right and left body areas. The 3D facial analysis revealed significant differences in soft tissues among orthopedic treatments, especially at the upper and lower lip and chin areas, as compared with untreated patients.

18 November 2023 in European Journal of Orthodontics
Verified
Journal Article
Closed access
PDF file
MPMario Palone
Mario Palone
MFMassimo Fazio
Massimo Fazio
FPFederica Pellitteri
Federica Pellitteri
DGDaniela Guiducci
Daniela Guiducci
FCFrancesca Cremonini
Francesca Cremonini
LLLuca Lombardo
Luca Lombardo
The widespread use of CAD/CAM transfer trays warrants evaluation of their accuracy as compared to PVS transfer trays. To quantify the accuracy of CAD/CAM and PVS transfer trays, investigating any differences between soft and hard trays CAD/CAM transfer trays. Eight different databases (Scopus, Web of Science, PubMed, Google Scholar, ProQuest, Embase, Cochrane Library, ClinicalTrials.gov) were searched, without restrictions, up to an end date of February 2023. Clinical trials (randomized and non-randomized) and in vitro studies reporting average imprecision values for bracket positioning obtained by digital superimpositions of digitally planned and real positions. Data eligibility, data extraction, and risk of bias (RoB-2 and ROBINS-I) were conducted independently. The data, where possible, were synthesized and quantitatively analysed (meta-analysis of mean differences with 95% confidence intervals). The Grade of Recommendation, Assessment, Development and Evaluation (GRADE) analysis of the quality of evidence was performed. The t-test for independent samples was used to compare the transfer accuracy of hard and soft CAD/CAM transfer trays. Thirteen studies were synthesized in this systematic review, and then eight studies were included in the quantitative meta-analysis. As regards linear measurements, there was a mean transfer error of 0.0752 mm (95%CI: 0.0428, 0.1076) for mesiodistal measures, 0.0943 mm (95%CI: 0.0402, 0.1484) for vertical, and 0.0815 mm (95%CI: 0.0469, 0.1160) for buccolingual. As for angular measurements, there was an average transfer error of 1.2279° (95% CI: 0.6011, 1.8548) for inclination, 0.9397° (95%CI: 0.4672, 1.4123) for angulation, and 0.8721° (95%CI: 0.4257, 1.3185) for rotation. CAD/CAM transfer trays were less accurate than polyvinylsiloxane (PVS) transfer trays, with those made of soft material being more accurate than the hard ones, except for vertical dimension. The GRADE quality of evidence ranged from very low to moderate. CAD/CAM transfer trays provide high bracket positioning accuracy, with soft transfer trays offering greater precision than rigid ones. Future randomized prospective trials are required to enhance the strength of the available evidence. Prospero (CRD42023401278 number)

24 March 2022 in Journal of Orthodontics
Verified
Journal Article
Closed access
MMManuela Maltoni
Manuela Maltoni
IMIvano Maltoni
Ivano Maltoni
GSGiorgia Santucci
Giorgia Santucci
DGDaniela Guiducci
Daniela Guiducci
FCFrancesca Cremonini
Francesca Cremonini
LLLuca Lombardo
Luca Lombardo
A male patient aged 11 years presented a large dentigerous cyst in the lower left quadrant associated with retained deciduous lower lateral incisor and canine and impacted, unerupted corresponding permanent ones. The treatment consisted in marsupialisation and placement of a modified lingual arch that held a tube for decompression used for irrigation of the cystic cavity in a comfortable way for the patient and for the clinician. The same lingual arch was later used as an anchorage method for traction of the retained teeth. The final records showed complete resolution of the cyst and retained teeth were successfully Aligned into the oral cavity.

19 September 2023 in Journal of the World Federation of Orthodontists
Verified
Journal Article
Closed access
MPMario Palone
Mario Palone
CBChiara Bizzocchi
Chiara Bizzocchi
DGDaniela Guiducci
Daniela Guiducci
FCFrancesca Cremonini
Francesca Cremonini
FPFederica Pellitteri
Federica Pellitteri
LLLuca Lombardo
Luca Lombardo

5 August 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
FCFrancesca Cremonini
Francesca Cremonini
ASAriyan Karami Shabankare
Ariyan Karami Shabankare
DGDaniela Guiducci
Daniela Guiducci
LLLuca Lombardo
Luca Lombardo
The aim was to objectively assess compliance in patients prescribed headgear and evaluate the impact of monitoring awareness, treatment duration, gender, and age on compliance levels. A total of 22 patients with Class II malocclusion wore the headgear integrated with the force and temperature sensitive Smartgear monitoring system (Smartgear, Swissorthodontics AG, Cham, Switzerland). Patients were instructed to wear the headgear for 13 h daily over a 3-month period. Randomly, 11 patients were informed that they monitored and 11 were not informed. Data were organized using Microsoft Excel and analyzed using R for statistical estimates, graphs, and hypothesis testing. Smartgear recorded an average daily compliance of 6.7 h. No statistically significant differences were found in cooperation between study group and control group over the 3 months of treatment, regardless of gender and age. However, there was slight greater cooperation in the first month than in the other months, and patients ≤10 years of age had almost 2 h more cooperation than their older counterparts. Moreover, the informed group exhibited an average of 1.1 more hours of cooperation per day than the uninformed group, which may carry clinical significance. This cooperation primarily occurred at night and was found to be statistically significant. Compliance among young patients typically remained lower than the prescribed level, regardless of their gender and psychological maturity. Although an awareness of monitoring does not seem to improve compliance, implementing such systems could still offer dentists a valuable means of obtaining objective information about their patients’ adherence.

12 September 2022 in Journal of Orthodontics
Verified
Journal Article
Closed access
MPMario Palone
Mario Palone
FCFrancesca Cremonini
Francesca Cremonini
DGDaniela Guiducci
Daniela Guiducci
LLLuca Lombardo
Luca Lombardo
Introduction: The aim of these two case-reports is to illustrate and compare the therapeutic effects of Class II elastics in combination with F22 aligners in an adult and an adolescent patient, respectively. Case presentation: Two patients with a mild skeletal Class II malocclusion, associated with mild-to-moderate crowding, presented for orthodontic treatment. The first patient was 12 years old, while the second was 40 years old. In both cases, the goal was to obtain bilateral molar and canine Class I with ideal overjet and overbite, and Class II skeletal relationship improvement in the young patient as well. Both treatments were approached without extractions and using clear aligners (CAs) in combination with Class II elastics, giving the patient the opportunity to take advantage of a therapy that is both comfortable and aesthetic. Discussion: Final records of both cases demonstrate how appropriate analysis and diagnosis enable CAs in conjunction with Class II elastics to be used with considerable efficiency and efficacy for Class II treatment. In the first case, the key to success was exploiting residual jaw growth, while in the second case it was careful orthodontic digital planning. Conclusion: In the presence of good patient compliance, CAs associated with Class II elastics provide satisfactory occlusal outcomes if biomechanics and digital set-up are carefully evaluated and executed and if diagnosis is appropriate.