Hidehiro Hojo

Dr. Hidehiro Hojo


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 February 2018 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
YHYasuhiro Hirano
Yasuhiro Hirano
MOMasakatsu Onozawa
Masakatsu Onozawa
HHHidehiro Hojo
Hidehiro Hojo
AMAtsushi Motegi
Atsushi Motegi
SZSadamoto Zenda
Sadamoto Zenda
TATetsuo Akimoto
Tetsuo Akimoto
The purpose of this study was to perform a dosimetric comparison between proton beam therapy (PBT) and photon radiation therapy in patients with locally advanced esophageal squamous cell carcinoma (ESCC) who were treated with PBT in our institution. In addition, we evaluated the correlation between toxicities and dosimetric parameters, especially the doses to normal lung or heart tissue, to clarify the clinical advantage of PBT over photon radiation therapy. A total of 37 consecutive patients with Stage III thoracic ESCC who had received PBT with or without concurrent chemotherapy between October 2012 and December 2015 were evaluated in this study. The dose distributions of PBT were compared with those of dummy 3-dimensional conformal radiation therapy (3DCRT) and Intensity Modulated Radiation Therapy (IMRT), focusing especially on the doses to organs at risk, such as normal lung and heart tissue. Of the 37 patients, the data from 27 patients were analyzed. Among these 27 patients, four patients (15%) developed grade 2 pericardial effusion as a late toxicity. None of the patients developed grade 3 or worse acute or late pulmonary and cardiac toxicities. When the dosimetric parameters between PBT and planned 3DCRT were compared, all the PBT domestic variables for the lung dose except for lung V10 GyE and V15 GyE were significantly lower than those for the dummy 3DCRT plans, and the PBT domestic variables for the heart dose were also significantly lower than those for the dummy 3DCRT plans. When the PBT and IMRT plans were compared, all the PBT domestic variables for the doses to the lung and heart were significantly lower than those for the dummy IMRT plans. Regarding the correlation between the grades of toxicities and the dosimetric parameters, no significant correlation was seen between the occurrence of grade 2 pericardial effusion and the dose to the heart. When the dosimetric parameters of the dose distributions for the treatment of patients with locally advanced stage III ESCC were compared between PBT and 3DCRT or IMRT, PBT enabled a significant reduction in the dose to the lung and heart, compared with 3DCRT or IMRT.

1 March 2017 in Radiotherapy and Oncology
Verified
Journal Article
Closed access
NNNaoki Nakamura
Naoki Nakamura
SZSadamoto Zenda
Sadamoto Zenda
MTMakoto Tahara
Makoto Tahara
SOSusumu Okano
Susumu Okano
RHRyuichi Hayashi
Ryuichi Hayashi
TATetsuo Akimoto
Tetsuo Akimoto

3 July 2017 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
HHHidehiro Hojo
Hidehiro Hojo
TDTakeshi Dohmae
Takeshi Dohmae
KHKenji Hotta
Kenji Hotta
RKRyosuke Kohno
Ryosuke Kohno
AMAtsushi Motegi
Atsushi Motegi
TATetsuo Akimoto
Tetsuo Akimoto
Cellular responses to proton beam irradiation are not yet clearly understood, especially differences in the relative biological effectiveness (RBE) of high-energy proton beams depending on the position on the Spread-Out Bragg Peak (SOBP). Towards this end, we investigated the differences in the biological effect of a high-energy proton beam on the target cells placed at different positions on the SOBP, using two human esophageal cancer cell lines with differing radiosensitivities. Two human esophageal cancer cell lines (OE21, KYSE450) with different radiosensitivities were irradiated with a 235-MeV proton beam at 4 different positions on the SOBP (position #1: At entry; position #2: At the proximal end of the SOBP; position #3: Center of the SOBP; position #4: At the distal end of the SOBP), and the cell survivals were assessed by the clonogenic assay. The RBE10 for each position of the target cell lines on the SOBP was determined based on the results of the cell survival assay conducted after photon beam irradiation. In addition, the number of DNA double-strand breaks was estimated by quantitating the number of phospho-histone H2AX (γH2AX) foci formed in the nuclei by immunofluorescence analysis. In regard to differences in the RBE of a proton beam according to the position on the SOBP, the RBE value tended to increase as the position on the SOBP moved distally. Comparison of the residual number of γH2AX foci at the end 24 h after the irradiation revealed, for both cell lines, a higher number of foci in the cells irradiated at the distal end of the SOPB than in those irradiated at the proximal end or center of the SOBP. The results of this study demonstrate that the RBE of a high-energy proton beam and the cellular responses, including the DNA damage repair processes, to high-energy proton beam irradiation, differ according to the position on the SOBP, irrespective of the radiosensitivity levels of the cell lines.

1 May 2019 in Clinical Lung Cancer
Verified
Journal Article
Open access
MNMasaki Nakamura
Masaki Nakamura
SKShun-Ichiro Kageyama
Shun-Ichiro Kageyama
SNSeiji Niho
Seiji Niho
MOMasayuki Okumura
Masayuki Okumura
HHHidehiro Hojo
Hidehiro Hojo
TATetsuo Akimoto
Tetsuo Akimoto

1 December 2021 in Biochemical and Biophysical Research Communications
Verified
Journal Article
Open access
JDJunyan Du
Junyan Du
SKShun-Ichiro Kageyama
Shun-Ichiro Kageyama
HHHidenari Hirata
Hidenari Hirata
AMAtsushi Motegi
Atsushi Motegi
MNMasaki Nakamura
Masaki Nakamura
TATetsuo Akimoto
Tetsuo Akimoto
Radiotherapy (RT) is an effective treatment option for cancer; however, its efficacy remains less than optimal in locally advanced cancer. Immune checkpoint inhibitor-based therapy, including the administration of anti-PD-L1 antibodies, is a promising approach that works synergistically with RT. Proton beam therapy and carbon-ion therapy are common options for patients with cancer. Proton and carbon ions are reported to induce an immune reaction in cancer cells; however, the underlying mechanisms remain unclear. Here, we aimed to compare the immune responses after irradiation (IR) with X-ray, protons, and carbon ions in an oesophageal cancer cell line and the underlying mechanisms. An oesophageal cancer cell line, KYSE450, was irradiated with 1 fraction/15 GyE (Gy equivalent) of X-ray, proton, or carbon-ion beams, and then, the cells were harvested for RNA sequencing and gene enrichment analysis. We also knocked out STING and STAT1 in the quest for mechanistic insights. RNA sequencing data revealed that gene expression signatures and biological processes were different in KYSE450 irradiated with X-ray, proton, and carbon-ion beams 6-24 h after IR. However, after 3 days, a common gene expression signature was detected, associated with biological pathways involved in innate immune responses. Gene knock-out experiments revealed that the STING-STAT1 axis underlies the immune reactions after IR. X-Ray, proton, and carbon-ion IRs induced similar immune responses, regulated by the STING-STAT1 axis.

16 March 2020 in Gastric Cancer
Verified
Journal Article
Closed access
PDF file
ASAkinori Sasaki
Akinori Sasaki
YNYoshiaki Nakamura
Yoshiaki Nakamura
YTYosuke Togashi
Yosuke Togashi
HKHirofumi Kuno
Hirofumi Kuno
HHHidehiro Hojo
Hidehiro Hojo
KSKohei Shitara
Kohei Shitara