Jesse Christensen

Dr. Jesse Christensen

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 September 2022 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
JCJesse Christensen
Jesse Christensen
ESEthan C. Stanley
Ethan C. Stanley
EOEvan G. Oro
Evan G. Oro
HCHunter B. Carlson
Hunter B. Carlson
YNYuval Y. Naveh
Yuval Y. Naveh
LTLevi S. Teitz
Levi S. Teitz
Objective: Primary purpose of this study was to determine the validity and reliability of the OneStep smartphone application in healthy adults. Secondary purpose was to determine the feasibility of measuring gait dysfunction, limitation in spatiotemporal characteristics, longitudinally in patients following total hip or knee arthroplasty. Methods: First objective, 20 healthy adults (mean age, 42.3 ± 19.7 years; 60% males; mean body mass index, 29.0 ± 5.2 kg/m2) underwent gait analysis under four gait conditions (self-selected gait speed, fixed gait speed at 0.8 m/s, fixed gait speed at 2.0 m/s and self-selected gait speed with dual task) for the validity and reliability of the smartphone to the motion laboratory. Reliability was determined by intraclass correlation coefficients. Validity was determined by Pearson correlations. Agreement was assessed by the Bland–Altman method. Second objective, 12 additional patients with total hip or knee arthroplasty (mean age, 58.7 ± 6.5 years; 58% males; mean body mass index, 28.9 ± 5.8 kg/m2) were measured at 2- and 10 weeks postoperatively. The smartphone application was used to evaluate change in gait dysfunction over time within the patients’ own environment using paired t test. Results: The smartphone application demonstrated moderate-to-excellent intraclass correlation coefficients for reliability between-system (ICC range, 0.56–0.99), -limb (ICC range, 0.62–0.99) and -device (ICC range, 0.61–0.96) for gait analysis of healthy adults. Pearson correlations were low-to-very high between methods (r range, 0.45–0.99). Bland–Altman analysis revealed relative underestimation of spatiotemporal variables by the smartphone application compared to the motion system. For patients following total hip or knee arthroplasty, gait analysis using the OneStep application demonstrated significant improvement (p < 0.001, Cohen’s d > 0.95) in gait dysfunction between 2- and 10 weeks postoperatively. Conclusion: The smartphone application can be a valid, reliable and feasible alternative to motion laboratories in evaluating deficits in gait dysfunction in various environments and clinical settings.

2 November 2020 in Journal of Orthopaedic Research
Verified
Journal Article
Closed access
PDF file
JCJesse Christensen
Jesse Christensen
JCJacob J. Capin
Jacob J. Capin
LHLauren A. Hinrichs
Lauren A. Hinrichs
MAMoiyad Aljehani
Moiyad Aljehani
JSJennifer E. Stevens‐Lapsley
Jennifer E. Stevens‐Lapsley
JZJoseph A. Zeni
Joseph A. Zeni

21 April 2020 in Disability and Rehabilitation
Verified
Journal Article
Closed access
JCJesse Christensen
Jesse Christensen
CPChristopher Peters
Christopher Peters
JGJeremy Gililland
Jeremy Gililland
GSGregory Stoddard
Gregory Stoddard
Purpose: To determine if preoperative physical and psychological health risk factors are influential on physical function and satisfaction scores in a cohort of relatively younger adults one year post-total knee arthroplasty. Methods: Sixty-five patients were recruited pre- and one year post-total knee arthroplasty. Physical (i.e., body mass index, sex, physical activity level, number of comorbidities) and psychological (i.e., depression, expectations, pain inference) health risk factors were obtained pre-total knee arthroplasty and compared to Patient-Reported Outcomes Measurement Information System physical function computerized adaptive testing and satisfaction scores one year post-total knee arthroplasty. Results: Bootstrap inclusion fraction methods were performed to compare the stability of each predictor variable prior to final regression analyzes. Poorer preoperative physical activity level (standardized regression coefficient = 0.37; p < 0.01), pain interference (standardized regression coefficient = –0.24; p = 0.03) and greater comorbidities (standardized regression coefficient = –0.27; p = 0.01) resulted in worse physical function scores one year post-total knee arthroplasty. Greater preoperative comorbidities (odds ratio = 0.63; p < 0.01) resulted in worse satisfaction scores one year post-total knee arthroplasty. No other predictor variable had any relationship on either clinical outcome (p > 0.05). Conclusion: Younger adults with greater comorbidities, lower physical activity level and higher pain interference scores preoperatively reported poorer functional recovery one year post-total knee arthroplasty. Understanding how preoperative status of younger adults undergoing total knee arthroplasty may lead to better improved surgical decision making and health care delivery for this vulnerable and growing patient subgroup.

27 July 2022 in European Journal of Rheumatology
Verified
Journal Article
Open access
JCJesse Christensen
Jesse Christensen
JJJason T. Jakiela
Jason T. Jakiela
DWDaniel K. White
Daniel K. White
Objective: The aim of the study was to investigate (1) trajectories of physical activity (PA) over 96 months and (2) study to what extent knee pain, muscle strength, physical function, and radiographic disease were associated with PA trajectories in adults with or at risk of knee osteoarthritis (KOA). Methods: Using the Osteoarthritis Initiative (OAI) database, we described PA trajectories with the Physical Activity Scale for the Elderly (PASE) over 96 months. Knee pain was categorized into three groups: “no pain” [visual numeric pain rating scale (VAS=0)], “little to some pain” (VAS=1-3), or “moderate to severe pain” (VAS ≥ 4). Knee extensor strength was classified into high [>16.21 (men) and >10.82 (women) N/kg/m2 ] and low [12 seconds) and fast (<12 seconds) groups. Radiographic disease was classified as present [Kellgren–Lawrence (KL) ≥2] or absent (KL grade <2) of KOA. Results: Among 3755 participants (age 61.0 ± 9.0 years, body mass index 28.5±4.8 kg/m2 , 58% female), we identified three trajectories: sedentary PA with slow decline (44.3%), low PA with slow decline (41.3%), and high PA with slow decline (14.4%). Poorer gait speed (OR: 2.32; 95% CI: 1.71-3.16), chair stand time (OR: 1.45; 95% CI: 1.07-1.96), and knee extensor strength (OR: 1.35; 95% CI: 1.03-1.76), but not pain or radiographic disease, were associated with PA trajectory of sedentary PA with slow decline. Conclusion: Physical function and strength, but not pain and radiographic disease, were associated with a trajectory of decline in PA among adults with or at risk of KOA. Cite this article as: Christensen JC, Jakiela JT, White DK. Factors associated with trajectories of physical activity over 8 years in knee osteoarthritis. Eur J Rheumatol. 2023;10(1):1-7.

9 September 2024 in Sensors
Verified
Journal Article
Open access
PDF file
CCCoby Contreras
Coby Contreras
ESEthan C. Stanley
Ethan C. Stanley
CDChanc Romulus Deschamps-Prescott
Chanc Romulus Deschamps-Prescott
SBSusan Burnap
Susan Burnap
MHMadison Jaye Hopkins
Madison Jaye Hopkins
JCJesse Christensen
Jesse Christensen
Objective: Advancements in smartphone technology provide availability to evaluate movement in a more practical and feasible manner, improving clinicians’ ability to diagnose and treat adults at risk for mobility loss. The purpose of this study was to evaluate the validity and reliability of a smartphone application to measure spatiotemporal outcomes during level (primary) and uphill/downhill (secondary) walking with and without an assistive device for older adults (OAs), Parkinson’s Disease (PD) and cerebrovascular accident (CVA) populations. Methods: A total of 50 adults (OA = 20; PD = 15; CVA = 15) underwent gait analysis at self-selected gait speeds under 0-degree, 5-degree uphill and 5-degree downhill environments. The validity and reliability of the smartphone outcomes were compared to a motion-capture laboratory. Bland–Altman analysis was used to evaluate limits of agreement between the two systems. Intraclass correlation coefficients (ICCs) were used to determine absolute agreement, and Pearson correlation coefficients (r) were used to assess the strength of the association between the two systems. Results: For level walking, Bland–Altman analysis revealed relatively equal estimations of spatiotemporal outcomes between systems for OAs without an assistive device and slight to mild under- and overestimations of outcomes between systems for PD and CVA with and without an assistive device. Moderate to very high correlations between systems (without an assistive device: OA r-range, 0.72–0.99; PD r-range, 0.87–0.97; CVA r-range, 0.56–0.99; with an assistive device: PD r-range, 0.35–0.98; CVA r-range, 0.50–0.99) were also observed. Poor to excellent ICCs for reliability between systems (without an assistive device: OA ICC range, 0.71–0.99; PD ICC range, 0.73–0.97; CVA ICC range, 0.56–0.99; with an assistive device: PD ICC range, 0.22–0.98; CVA ICC range, 0.44–0.99) were observed across all outcomes. Conclusions: This smartphone application can be clinically useful in detecting most spatiotemporal outcomes in various walking environments for older and diseased adults at risk for mobility loss.

25 January 2025 in Arthritis Care & Research
Verified
Journal Article
Closed access
MBMichael J. Bade
Michael J. Bade
CCCory L. Christiansen
Cory L. Christiansen
JZJoseph A. Zeni
Joseph A. Zeni
MDMichael R. Dayton
Michael R. Dayton
JFJeri E. Forster
Jeri E. Forster
JSJennifer E. Stevens‐Lapsley
Jennifer E. Stevens‐Lapsley