Atherosclerotic plaques constitute the primary cause of heart attack and stroke. However, we still lack a clear identification of the plaques. Here, we evaluate the feasibility of scanning acoustic microscopy (SAM) and time-resolved fluorescence spectroscopy (TRFS) in atherosclerotic plaque characterization. We perform dual-modality microscopic imaging of the human carotid atherosclerotic plaques. We first show that the acoustic impedance values are statistically higher in calcified regions compared with the collagen-rich areas. We then use CdTe/CdS quantum dots for imaging the atherosclerotic plaques by TRFS and show that fluorescence lifetime values of the quantum dots in collagen-rich areas are notably different from the ones in calcified areas. In summary, both modalities are successful in differentiating the calcified regions from the collagen-rich areas within the plaques indicating that these techniques are confirmatory and may be combined to characterize atherosclerotic plaques in the future.
Microcalcification is the precursor of vulnerability of plaques in humans. Visualization of such small structures in vivo with high spatial resolution is an unsolved issue. The goal of this study is to evaluate the potential of scanning acoustic microscopy (SAM) in the determination of atherosclerotic plaques with calcifications by validating this technique with micro-computer tomography (micro-CT), scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). The fibrocalcific plaques were obtained from 12 different patients and initially examined with micro-CT. The images exhibited calcifications within these plaques. For imaging with SAM, approximately 5 μm thick slices were prepared. Sound speed values within calcified regions were measured to be greater than the ones in collagen-rich regions. These fibrocalcific plaques were also examined with SEM and EDS revealing collagen and calcium deposition within these samples. The consistency of the results obtained by all of the modalities involved in our study is an indication of the potential of SAM as a clinical tool for the diagnosis of vulnerable plaques.
24 October 2024 in Journal of Science: Advanced Materials and Devices
Projectile foreign bodies are known to cause chronic heavy metal toxicity due to the release of metal into the bloodstream. However, the local effect around the metallic object has not been investigated and the main goal of our study is to examine the influence of the object in close proximity of the object. A 36-year-old Caucasian woman with one metallic pellet close to her sciatic nerve due to a previous shotgun injury at the gluteal area presented with a diagnosis of recurrent lumbar disk herniation at L4–5 level. A physical examination confirmed chronic neuropathy and she underwent a two-stage surgery. The surgery included removal of the foreign body, followed by discectomy and fusion at the involved level. During the removal of the metallic foreign body, a tissue sample around the pellet and another tissue sample from a remote area were obtained. The samples were analyzed by scanning acoustic microscopy, scanning electron microscopy, and energy-dispersive X-ray spectroscopy. Lead, chromium, copper, cadmium, iron, manganese, selenium, and zinc elements in tissue, blood, and serum specimens were detected by inductively coupled plasma optical emission spectroscopy. An acoustic impedance map of the tissue closer to the metallic body showed higher values indicating further accumulation of elements. Energy-dispersive X-ray spectroscopy results confirmed scanning acoustic microscopy results by measuring a higher concentration of elements closer to the metallic body. Scanning electron microscopy images showed that original structure was not disturbed far away; however, deformation of the structure existed in the tissue closer to the foreign body. Element analysis showed that element levels within blood and serum were more or less within acceptable ranges; on the other hand, element levels within the tissues showed pronounced differences indicating primarily lead intoxication in the proximity of the metallic body. We can state that residues of metallic foreign bodies of gunshot injuries cause chronic metal infiltration to the surrounding tissue and induce significant damage to nearby neural elements; this is supported by the results of scanning acoustic microscopy, scanning electron microscopy, energy-dispersive X-ray spectroscopy, and inductively coupled plasma optical emission spectroscopy.
Aortic aneurysm is observed as a result of the extensive alteration in the elasticity of the aortic wall due to the breakdown of elastin and collagen. In this study, we studied the feasibility of scanning acoustic microscopy (SAM) and Raman spectroscopy (RS) in characterizing the dilated segments of the aorta from male and female patients with aortic aneurysm. SAM determined the acoustic property variation in the aorta by calculating the acoustic impedance values of aorta samples of 18 patients. RS determined the disease states by analyzing the chemical variation especially in the peaks related to elastin and collagen using the k-means classification method. Consequently, we assume that combining these two techniques in clinics will help to investigate the dilated segment of the aorta with micrometer resolution, which will reduce the possibility of new aneurysm formation due to a segment not excised during the surgery.
7 May 2020 in Biomedical Physics & Engineering Express
Calcium deposition within the atherosclerotic plaques is the precursor of cardiovascular complications. Therefore, determination of levels of minerals and trace elements in blood plays an important role in assigning the stage of atherosclerosis. In this study, determination of mineral and trace element levels in atherosclerotic patients is aimed. Mineral and trace element levels within serum samples of 12 atherosclerotic patients were evaluated by Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) and phosphorous (P), iron (Fe), magnesium (Mg) and calcium (Ca) levels were examined. Human carotid atherosclerotic plaque samples were previously screened by Scanning Acoustic Microscopy (SAM) and sound speed maps of the plaques showed higher sound speed values in the calcified regions, when compared to collagen-rich regions, indicating accumulation of calcium. Element analysis also showed increased Ca levels within serum samples. Therefore, it can be concluded that Ca deposition can be examined by ICP-OES and SAM, indicating that these techniques are confirmatory and may be combined to characterize atherosclerosis in the future.