Marcelo Henrique Farias de Medeiros

Prof. Dr. Marcelo Henrique Farias de Medeiros

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

24 January 2007 in Materials and Structures
Verified
Journal Article
Closed access
PDF file
Marcelo Henrique Farias de MedeirosMarcelo Henrique Farias de Medeiros
Marcelo Henrique Farias de Medeiros
PHP. Helene
P. Helene

1 April 2020 in Journal of Environmental Chemical Engineering
Verified
Journal Article
Closed access
Romildo Alves Alves BerenguerRomildo Alves Alves Berenguer
Romildo Alves Alves Berenguer
ACAna Paula B. Capraro
Ana Paula B. Capraro
Marcelo Henrique Farias de MedeirosMarcelo Henrique Farias de Medeiros
Marcelo Henrique Farias de Medeiros
ARNALDO MANOEL PEREIRA CARNEIROARNALDO MANOEL PEREIRA CARNEIRO
ARNALDO MANOEL PEREIRA CARNEIRO
RORomilde A. De Oliveira
Romilde A. De Oliveira

1 July 2009 in Construction and Building Materials
Verified
Journal Article
Closed access
Marcelo Henrique Farias de MedeirosMarcelo Henrique Farias de Medeiros
Marcelo Henrique Farias de Medeiros
PHP. Helene
P. Helene
SSS. Selmo
S. Selmo

1 March 2013 in Journal of Materials in Civil Engineering
Verified
Journal Article
Closed access
JFJ. Hoppe Filho
J. Hoppe Filho
Marcelo Henrique Farias de MedeirosMarcelo Henrique Farias de Medeiros
Marcelo Henrique Farias de Medeiros
EPE. Pereira
E. Pereira
PHP. Helene
P. Helene
GIG. C. Isaia
G. C. Isaia
Fly ash changes the microstructure of paste and can increase concrete durability. Calcium hydrated lime was added to concrete with 50% of the cement, by weight, substituted with fly ash, with the intent of replacing some of the calcium hydroxide consumed by the pozzolanic activity. Three proportions of mixes were studied: concrete with high early strength cement (HESC), concrete with 50% HESC and 50% fly ash, and concrete with 50% HESC, 50% fly ash and an additional 20% of hydrated lime. They were then tested according to ASTM C1202, but with the application of a voltage of 30 V during 35 h. Results revealed that concretes containing fly ash and hydrated lime presented a lower accumulated charge density and coefficient of chloride diffusion than the HESC concrete used as a reference.

1 July 2013 in Construction and Building Materials
Verified
Journal Article
Closed access
Marcelo Henrique Farias de MedeirosMarcelo Henrique Farias de Medeiros
Marcelo Henrique Farias de Medeiros
AGA. Gobbi
A. Gobbi
GRG.C. Réus
G.C. Réus
PHP. Helene
P. Helene