Yan Wu

Yan Wu


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2022 in Quantitative Imaging in Medicine and Surgery
Verified
Journal Article
Open access
PDF file
YLYali Li
Yali Li
YJYaojun Jiang
Yaojun Jiang
Huilong LiuHuilong Liu
Huilong Liu
XYXi Yu
Xi Yu
SCSihui Chen
Sihui Chen
YWYan Wu
Yan Wu
A phantom study comparing low-dose CT physical image quality from five different CT scanners Yali Li, Yaojun Jiang, Huilong Liu, Xi Yu, Sihui Chen, Duoshan Ma, Jianbo Gao, Yan Wu

1 February 2018 in Quantitative Imaging in Medicine and Surgery
Verified
Journal Article
Closed access
PDF file
YWYan Wu
Yan Wu
YJYaojun Jiang
Yaojun Jiang
XHXueli Han
Xueli Han
MWMingyue Wang
Mingyue Wang
JGJianbo Gao
Jianbo Gao
Background: To investigate the repeatability and accuracy of quantitative CT (QCT) measurement of bone mineral density (BMD) by low-mAs using iterative model reconstruction (IMR) technique based on phantom model. Methods: European spine phantom (ESP) was selected and measured on the Philips Brilliance iCT Elite FHD machine for 10 times. Data were transmitted to the QCT PRO workstation to measure BMD (mg/cm3) of the ESP (L1, L2, L3). Scanning method: the voltage of X-ray tube is 120 kV, the electric current of X-ray tube output in five respective groups A–E were: 20, 30, 40, 50 and 60 mAs. Reconstruction: all data were reconstructed using filtered back projection (FBP), IR levels of hybrid iterative reconstruction (iDose4, levels 1, 2, 3, 4, 5, 6 were used) and IMR (levels 1, 2, 3 were used). ROIs were placed in the middle of L1, L2 and L3 spine phantom in each group. CT values, noise and contrast-to-noise ratio (CNR) were measured and calculated. One-way analysis of variance (ANOVA) was used to compare BMD values of different mAs and different IMR. Results: Radiation dose [volume CT dose index (CTDIvol) and dose length product (DLP)] was positively correlated with tube current. In L1 with low BMD, different mAs in FBP showed P0.05, indicating no difference in BMD. And P>0.05 was observed among BMD of spine phantom in L1, L2 and L3 under same mAs joined with varied iterative reconstruction. The BMD in L1 varied greatly during FBP reconstruction, and less variation was observed in reconstruction of IMR [1] and IMR [2]. The BMD of L2 changed more during FBP reconstruction, where less was observed in IMR [2]. The BMD of L3 varied greatly during FBP reconstruction, and was less varied in all levels of iDose4 and reconstruction of IMR [2]. In addition, along with continuous mAs incensement, the CNRs in various algorithms continued to increase. Among them, CNR with the FBP algorithm is the lowest, and CNR of the IMR [3] algorithm is the highest. Conclusions: Repeated measurements of BMD with QCT in the ESP multicenter showed that BMD changes in L1–L3 are the least varied at IMR [2] algorithm. It is recommended to scan at 120 kV with 20 mAs combined with IMR [2] algorithm. In this way, the BMD of spine by QCT could be accurately measured, while radiation dosage significantly reduced and imaging quality improved at the same time.

11 August 2022 in Frontiers in Endocrinology
Verified
Journal Article
Open access
YLYali Li
Yali Li
YJYaojun Jiang
Yaojun Jiang
XYXi Yu
Xi Yu
BRBinbin Ren
Binbin Ren
CWChunyu Wang
Chunyu Wang
YWYan Wu
Yan Wu
Background and purpose: To investigate the image quality and accurate bone mineral density (BMD) on quantitative CT (QCT) for osteoporosis screening by deep-learning image reconstruction (DLIR) based on a multi-phantom and patient study.Materials and methods: High-contrast spatial resolution, low-contrast detectability, modulation function test (MTF), noise power spectrum (NPS), and image noise were evaluated for physical image quality on Caphan 500 phantom. Three calcium hydroxyapatite (HA) inserts were used for accurate BMD measurement on European Spine Phantom (ESP). CT images were reconstructed with filtered back projection (FBP), adaptive statistical iterative reconstruction-veo 50% (ASiR-V50%), and three levels of DLIR(L/M/H). Subjective evaluation of the image high-contrast spatial resolution and low-contrast detectability were compared visually by qualified radiologists, whilst the statistical difference in the objective evaluation of the image high-contrast spatial resolution and low-contrast detectability, image noise, and relative measurement error were compared using one-way analysis of variance (ANOVA). Cohen’s kappa coefficient (k) was performed to determine the interobserver agreement in qualitative evaluation between two radiologists.Results: Overall, for three levels of DLIR, 50% MTF was about 4.50 (lp/cm), better than FBP (4.12 lp/cm) and ASiR-V50% (4.00 lp/cm); the 2 mm low-contrast object was clearly resolved at a 0.5% contrast level, while 3mm at FBP and ASiR-V50%. As the strength level decreased and radiation dose increased, DLIR at three levels showed a higher NPS peak frequency and lower noise level, leading to leftward and rightward shifts, respectively. Measured L1, L2, and L3 were slightly lower than that of nominal HA inserts (44.8, 95.9, 194.9 versus 50.2, 100.6, 199.2mg/cm3) with a relative measurement error of 9.84%, 4.08%, and 2.60%. Coefficients of variance for the L1, L2, and L3 HA inserts were 1.51%, 1.41%, and 1.18%. DLIR-M and DLIR-H scored significantly better than ASiR-V50% in image noise (4.83 ± 0.34, 4.50 ± 0.50 versus 4.17 ± 0.37), image contrast (4.67 ± 0.73, 4.50 ± 0.70 versus 3.80 ± 0.99), small structure visibility (4.83 ± 0.70, 4.17 ± 0.73 versus 3.83 ± 1.05), image sharpness (3.83 ± 1.12, 3.53 ± 0.90 versus 3.27 ± 1.16), and artifacts (3.83 ± 0.90, 3.42 ± 0.37 versus 3.10 ± 0.83). The CT value, image noise, contrast noise ratio, and image artifacts in DLIR-M and DLIR-H outperformed ASiR-V50% and FBP (P0.05). The prevalence of osteoporosis was 74 (24.67%) in women and 49 (11.79%) in men, whilst the osteoporotic vertebral fracture rate was 26 (8.67%) in women and (5.29%) in men.Conclusion: Image quality with DLIR was high-qualified without affecting the accuracy of BMD measurement. It has a potential clinical utility in osteoporosis screening.

1 August 2009 in Bone
Verified
Journal Article
Closed access
YWYan Wu
Yan Wu
CBCatherine Bergot
Catherine Bergot
EJErwan Jolivet
Erwan Jolivet
LZLq Zhou
Lq Zhou
JLJean-Denis Laredo
Jean-Denis Laredo
VBValérie Bousson
Valérie Bousson

23 June 2022 in Frontiers in Endocrinology
Verified
Journal Article
Open access
SCSihui Chen
Sihui Chen
DMDuoshan Ma
Duoshan Ma
DSDanyang Su
Danyang Su
YLYali Li
Yali Li
XYXi Yu
Xi Yu
YWYan Wu
Yan Wu
Purpose: Determine the association between cross-sectional visceral adipose tissue (VAT) area of different anatomic locations and total abdominopelvic VAT volume; identify the optimal measurement site in a single-slice to quantify the total VAT volume.Method: Participants who underwent non-contrast abdominal scan by quantitative CT (QCT) were enrolled from May 2021 to October 2021. The VAT area (cm2) at different anatomic sites as upper-pole, lower-pole, and hilum of the kidney, intervertebral disc of L2/L3 and L5/S1, and umbilical level were measured on QCT PRO BMD workstation (Mindways QCT PRO workstation). The total VAT volume (cm3) from the upper pole of kidney to the L5/S1 intervertebral disc of the pelvis (abdominopelvic region) was obtained by using Siemens Healthineers Syngo via Frontier cardiac risk assessment. Regression models were used to identify the optimal single-slice in different gender for estimating VAT volume. Statistical significance was established at P < 0.05.Results: Total of 311 Chinese participants including 179 men [age, 55.1 ± 14.9 years; body mass index (BMI), 24.2 ± 3.2 kg/m2; total VAT volume, 2482.6 ± 1276.5 mL] and 132 women [age, 54.3 ± 14.9; BMI, 23.5 ± 2.9; total VAT volume, 1761.5 ± 876.4]. Pearson’s correlation analysis revealed a strong association between the VAT area and total abdominopelvic VAT volume at the hilum of the kidney in both men (r=0.938, P<0.001) and women (r=0.916, P<0.001). Adjust for covariates including age, BMI, and waist circumference make a relatively small effect on predicting the total VAT volume.Conclusions: Measurement of cross-sectional areas at the hilum of the kidney in both genders showed a strongest relation to TVAT volume. Our results may provide an identifiable and valuable axial landmark for measuring visceral adipose tissue in clinical practice.

11 March 2025 in Calcified Tissue International
Verified
Journal Article
Closed access
PDF file
YWYan Wang
Yan Wang
DMDuoshan Ma
Duoshan Ma
CWChunyu Wang
Chunyu Wang
XZXinxin Zhang
Xinxin Zhang
MTMengna Tang
Mengna Tang
YWYan Wu
Yan Wu