The etiology of the reduced marginal bone loss observed around platform-switched implant-abutment connections is not clear but could be related to the release of variable amounts of corrosion products. The present study evaluated the effect of different concentrations of metal ions released from different implant abutment couples on osteoblastic cell viability, apoptosis and expression of genes related to bone resorption. Osteoblastic cells were exposed to five conditions of culture media prepared containing metal ions (titanium, aluminum, vanadium, cobalt, chromium and molybdenum) in different concentrations representing the amounts released from platform-matched and platform-switched implant-abutment couples as a result of an earlier accelerated corrosion experiment. Cell viability was evaluated over 21days using the Alamar Blue assay. Induction of apoptosis was measured after 24h of exposure using flow cytometry. Expression of interleukin-6, interleukin-8, cyclooxygenase-2, caspase-8, osteoprotegerin and receptor activator of nuclear factor kappa-B ligand (RANKL) by osteoblastic cells were analysed after exposure for 1, 3 and 21days using real-time quantitative polymerase chain reaction assay RESULTS: Metal ions in concentrations representing the platform-matched groups led to a reduction in cell viability (P<0.01) up to 7days of exposure. Stimulated cells showed higher rates of early apoptosis (P<0.01) compared to non-treated cells. Metal ions up-regulated the expression of interleukin-6, interleukin-8, cyclooxygenase-2 and RANKL in a dose dependent manner after 1day of exposure (P<0.05). The up-regulation was more pronounced in the groups containing the corrosion products of platform-matched implant-abutment couples. Osteoblastic cell viability, apoptosis, and regulation of bone resorbing mediators were significantly altered in the presence of metal ions. The change in cytokine levels expressed was directly proportional to the metal ion concentration. The observed biological responses to decreased amounts of metal ions released from platform-switched implant-abutment couples compared to platform-matched couples may partly explain the positive radiographic findings in respect to crestal bone level when utilising the "platform-switching" concept, which highlights the possible role of corrosion products in the mediation of crestal bone loss around dental implants.
(1) Objectives: This study investigated and compared the wear and flexural strength of two highly filled (injectable), one flowable and one paste composite. (2) Methods: Two highly filled flowable composites (G-aenial Universal Injectable and Beautifil Plus F00), a paste composite (Empress Direct) and a conventional flowable (Tetric EvoFlow) were tested. A two-body wear test was carried out using 10 disc-shaped samples from each group, which were subjected to 200,000 wear machine cycles to simulate wear, followed by Scanning Electron Microscope analysis. Flexural strength was tested using a three-point bend test using 15 beam samples for each of the four groups. Values were statistically compared using one-way analysis of variance (ANOVA) for flexural strength and a Kruskal–Wallis test for wear. (3) Results: The median volume loss for G-aenial Universal Injectable and Beautifil Plus F00 was statistically lower than that of both Empress Direct and Tetric EvoFlow. For flexural strength the two highly filled flowable composites both exhibited statistically higher mean flexural strength values compared to Empress Direct (p < 0.004) and Tetric Evoflow (p < 0.001). There were no statistically significant differences in the values of wear and flexural strength between the two highly filled flowable composites. (4) Conclusions/significance: Highly filled flowable composite resins with nano filler particles outperformed a conventional flowable and a paste composite resin in terms of wear resistance and flexural strength, and may be suitable to use in occlusal, load-bearing areas.
27 May 2016 in International Journal of Oral Science
The improved peri-implant bone response demonstrated by platform switching may be the result of reduced amounts of metal ions released to the surrounding tissues. The aim of this study was to compare the levels of metal ions released from platform-matched and platform-switched implant–abutment couples as a result of accelerated corrosion. Thirty-six titanium alloy (Ti-6Al-4V) and cobalt–chrome alloy abutments were coupled with titanium cylinders forming either platform-switched or platform-matched groups (n=6). In addition, 18 unconnected samples served as controls. The specimens were subjected to accelerated corrosion by static immersion in 1% lactic acid for 1 week. The amount of metal ions ion of each test tube was measured using inductively coupled plasma mass spectrometry. Scanning electron microscope (SEM) images and energy dispersive spectroscopy X-ray analyses were performed pre- and post-immersion to assess corrosion at the interface. The platform-matched groups demonstrated higher ion release for vanadium, aluminium, cobalt, chrome, and molybdenum compared with the platform-switched groups (P<0.05). Titanium was the highest element to be released regardless of abutment size or connection (P<0.05). SEM images showed pitting corrosion prominent on the outer borders of the implant and abutment platform surfaces. In conclusion, implant–abutment couples underwent an active corrosion process resulting in metal ions release into the surrounding environment. The highest amount of metal ions released was recorded for the platform-matched groups, suggesting that platform-switching concept has a positive effect in reducing the levels of metal ion release from the implant–abutment couples.
The reduced marginal bone loss observed when using the platform-switching concept may be the result of reduced amounts of tribocorrosion products released to the peri-implant tissues. Therefore, the purpose of this study was to compare the tribocorrosion product release from various platform-matched and platform-switched implant-abutment couplings under cyclic loading. Forty-eight titanium implants were coupled with pure titanium, gold alloy, cobalt-chrome alloy, and zirconia abutments forming either platform-switched or platform-matched groups ( n = 6). The specimens were subjected to cyclic occlusal forces in a wet acidic environment for 24 h followed by static aqueous immersion for 6 d. The amount of metal ions released was measured using inductively coupled plasma mass spectrometry. Microscopic evaluations were performed pre- and postimmersion under scanning electron microscope (SEM) equipped with energy-dispersive spectroscopy X-ray for corrosion assessment at the interface and wear particle characterization. All platform-switched groups showed less metal ion release compared with their platform-matched counterparts within each abutment material group ( P < 0.001). Implants connected to platform-matched cobalt-chrome abutments demonstrated the highest total mean metal ion release (218 ppb), while the least total mean ion release (11 ppb) was observed in the implants connected to platform-switched titanium abutments ( P ≤ 0.001). Titanium was released from all test groups, with its highest mean release (108 ppb) observed in the implants connected to platform-matched gold abutments ( P < 0.001). SEM images showed surface tribocorrosion features such as pitting and bands of fretting scars. Wear particles were mostly titanium, ranging from submicron to 48 µm in length. The platform-matched groups demonstrated a higher amount of metal ion release and more surface damage. These findings highlight the positive effect of the platform-switching concept in the reduction of tribocorrosion products released from dental implants, which consequently may minimize the adverse tissue reactions that lead to peri-implant bone loss.