Martin Piringer

Dr. Martin Piringer

ZAMG
orcid

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 April 2016 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
Jean-Baptiste RenardJean-Baptiste Renard
Jean-Baptiste Renard
FDFrançois Dulac
François Dulac
GBGwenaël Berthet
Gwenaël Berthet
TLThibaut Lurton
Thibaut Lurton
DVDamien Vignelles
Damien Vignelles
DDDaniel Daugeron
Daniel Daugeron
The study of aerosols in the troposphere and in the stratosphere is of major importance both for climate and air quality studies. Among the numerous instruments available, optical aerosol particles counters (OPCs) provide the size distribution in diameter range from about 100 nm to a few tens of µm. Most of them are very sensitive to the nature of aerosols, and this can result in significant biases in the retrieved size distribution. We describe here a new versatile optical particle/sizer counter named LOAC (Light Optical Aerosol Counter), which is light and compact enough to perform measurements not only at the surface but under all kinds of balloons in the troposphere and in the stratosphere. LOAC is an original OPC performing observations at two scattering angles. The first one is around 12°, and is almost insensitive to the refractive index of the particles; the second one is around 60° and is strongly sensitive to the refractive index of the particles. By combining measurement at the two angles, it is possible to retrieve the size distribution between 0.2 and 100 µm and to estimate the nature of the dominant particles (droplets, carbonaceous, salts and mineral particles) when the aerosol is relatively homogeneous. This typology is based on calibration charts obtained in the laboratory. The uncertainty for total concentrations measurements is ±20 % when concentrations are higher than 1 particle cm−3 (for a 10 min integration time). For lower concentrations, the uncertainty is up to about ±60 % for concentrations smaller than 10−2 particle cm−3. Also, the uncertainties in size calibration are ±0.025 µm for particles smaller than 0.6 µm, 5 % for particles in the 0.7–2 µm range, and 10 % for particles greater than 2 µm. The measurement accuracy of submicronic particles could be reduced in a strongly turbid case when concentration of particles > 3 µm exceeds a few particles cm−3. Several campaigns of cross-comparison of LOAC with other particle counting instruments and remote sensing photometers have been conducted to validate both the size distribution derived by LOAC and the retrieved particle number density. The typology of the aerosols has been validated in well-defined conditions including urban pollution, desert dust episodes, sea spray, fog, and cloud. Comparison with reference aerosol mass monitoring instruments also shows that the LOAC measurements can be successfully converted to mass concentrations.

1 September 2017 in Atmospheric Environment
Verified
Journal Article
Closed access
CWChuandong Wu
Chuandong Wu
JLJiemin Liu
Jiemin Liu
PZPeng Zhao
Peng Zhao
WLWenhui Li
Wenhui Li
LYLuchun Yan
Luchun Yan
Günther SchaubergerGünther Schauberger
Günther Schauberger

1 February 2016 in Atmospheric Environment
Verified
Journal Article
Open access
CWChuandong Wu
Chuandong Wu
JLJiemin Liu
Jiemin Liu
PZPeng Zhao
Peng Zhao
Martin PiringerMartin Piringer
Martin Piringer
Günther SchaubergerGünther Schauberger
Günther Schauberger
Continuous odour measurements both of emissions as well as ambient concentrations are seldom realised, mainly because of their high costs. They are therefore often substituted by concentration measurements of odorous substances. Then a conversion of the chemical concentrations C (mg m-3) into odour concentrations COD (ouE m-3) and odour intensities OI is necessary. Four methods to convert the concentrations of single substances to the odour concentrations and odour intensities of an odorous mixture are investigated: (1) direct use of measured concentrations, (2) the sum of the odour activity value SOAV, (3) the sum of the odour intensities SOI, and (4) the equivalent odour concentration EOC, as a new method. The methods are evaluated with olfactometric measurements of seven substances as well as their mixtures. The results indicate that the SOI and EOC conversion methods deliver reliable values. These methods use not only the odour threshold concentration but also the slope of the Weber-Fechner law to include the sensitivity of the odour perception of the individual substances. They fulfil the criteria of an objective conversion without the need of a further calibration by additional olfactometric measurements.Comment: accepted for publication on Dec. 20, 2015, Atmospheric Environment (2016

1 January 2011 in International Journal of Environment and Pollution
Verified
Journal Article
Closed access
SSSILVANA DI SABATINO
SILVANA DI SABATINO
Riccardo BuccolieriRiccardo Buccolieri
Riccardo Buccolieri
HOHelge R. Olesen
Helge R. Olesen
MKMatthias KETZEL
Matthias KETZEL
RBRuwim Berkowicz
Ruwim Berkowicz
ASAlexander V. Starchenko
Alexander V. Starchenko
The aim of this paper is to describe the use of a general methodology tailored to the evaluation of micro-scale meteorological models applied to flow and dispersion simulations in urban areas. This methodology, developed within COST 732, has been tested through a large modelling exercise involving many groups across Europe. The major test case used is the Mock Urban Setting Test (MUST) experiment representing an idealised urban area. It is emphasised that a full model evaluation is problem-dependent and requires several activities including a statistical validation that requires a careful choice of the metrics for the comparison with measurements.

9 August 2016 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
Jean-Baptiste RenardJean-Baptiste Renard
Jean-Baptiste Renard
FDFrançois Dulac
François Dulac
GBGwenaël Berthet
Gwenaël Berthet
TLThibaut Lurton
Thibaut Lurton
DVDamien Vignelles
Damien Vignelles
DDDaniel Daugeron
Daniel Daugeron
In the companion (Part I) paper, we have described and evaluated a new versatile optical particle counter/sizer named LOAC (Light Optical Aerosol Counter), based on scattering measurements at angles of 12 and 60°. That allows for some typology identification of particles (droplets, carbonaceous, salts, and mineral dust) in addition to size-segregated counting in a large diameter range from 0.2 µm up to possibly more than 100 µm depending on sampling conditions (Renard et al., 2016). Its capabilities overpass those of preceding optical particle counters (OPCs) allowing the characterization of all kind of aerosols from submicronic-sized absorbing carbonaceous particles in polluted air to very coarse particles (> 10–20 µm in diameter) in desert dust plumes or fog and clouds. LOAC's light and compact design allows measurements under all kinds of balloons, on-board unmanned aerial vehicles (UAVs) and at ground level. We illustrate here the first LOAC airborne results obtained from a UAV and a variety of scientific balloons. The UAV was deployed in a peri-urban environment near Bordeaux in France. Balloon operations include (i) tethered balloons deployed in urban environments in Vienna (Austria) and Paris (France), (ii) pressurized balloons drifting in the lower troposphere over the western Mediterranean (during the Chemistry-Aerosol Mediterranean Experiment – ChArMEx campaigns), (iii) meteorological sounding balloons launched in the western Mediterranean region (ChArMEx) and from Aire-sur-l'Adour in south-western France (VOLTAIRE-LOAC campaign). More focus is put on measurements performed in the Mediterranean during (ChArMEx) and especially during African dust transport events to illustrate the original capability of balloon-borne LOAC to monitor in situ coarse mineral dust particles. In particular, LOAC has detected unexpected large particles in desert sand plumes.

22 February 2006 in Atmospheric Chemistry and Physics
Verified
Journal Article
Open access
PDF file
BFB. Fisher
B. Fisher
JKJ. Kukkonen
J. Kukkonen
Martin PiringerMartin Piringer
Martin Piringer
MRM. W. Rotach
M. W. Rotach
MSM. Schatzmann
M. Schatzmann
The outcome of COST 715 is reviewed from the viewpoint of a potential user who is required to consider urban meteorology within an air pollution assessment. It is shown that descriptive concepts are helpful for understanding the complex structure of the urban boundary layer, but that they only apply under a limited number of conditions. However such concepts are necessary to gain insight into both simple and complex air pollution models. It is argued that wider considerations are needed when considering routine air quality assessments involving an air quality model's formulation and pedigree. Moreover there appears to be a reluctance from model developers to move away from familiar concepts of the atmospheric boundary layer even if they are not appropriate to urban areas. An example is given from COST 715 as to how routine urban meteorological measurements of wind speed may be used and adapted for air quality assessments. Reference to the full COST 715 study is made which provides further details.