Chaobing Gao

Dr. Chaobing Gao

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 December 2024 in Cellular Signalling
Verified
Journal Article
Closed access
HHHongting Hua
Hongting Hua
XYXiaonan Yang
Xiaonan Yang
DMDongdong Meng
Dongdong Meng
RGRuijia Gan
Ruijia Gan
NCNuo Chen
Nuo Chen
CGChaobing Gao
Chaobing Gao

4 November 2025 in Hepatology
Verified
Journal Article
Closed access
HHHongting Hua
Hongting Hua
DWDong Wang
Dong Wang
LHLanqiaofeng He
Lanqiaofeng He
NCNuo Chen
Nuo Chen
ZGZongshi Gao
Zongshi Gao
CGChaobing Gao
Chaobing Gao
Background and Aims: Obstructive sleep apnea (OSA), characterized by recurrent episodes of intermittent hypoxia (IH), is increasingly recognized as a contributor to metabolic disorders, including metabolic dysfunction-associated steatotic liver disease (MASLD). However, the causal relationship and underlying molecular mechanisms linking IH and MASLD remain incompletely understood, hindering the development of effective therapeutic strategies. Approach and Results: We established murine and cellular models of IH and performed comprehensive metabolic and molecular profiling, including glucose and insulin tolerance tests, biochemical analyses, histology, lipidomics, real-time quantitative PCR, western blotting, RNA sequencing, chromatin immunoprecipitation (ChIP) sequencing, ChIP assay, co-immunoprecipitation, and luciferase reporter gene assays, to investigate the impact of IH and the role of KLF9 in hepatic lipid metabolism. The findings showed IH exposure induced hepatic lipid accumulation and insulin resistance in both normal and obese mice, accompanied by transcriptional reprogramming of lipid metabolic pathways. Transcriptomic analysis identified KLF9 as significantly upregulated by IH treatment. Functional studies demonstrated that hepatic overexpression of KLF9 exacerbated, while its knockdown alleviated, IH-induced steatosis, lipogenesis, and inflammation. Mechanistically, KLF9 directly binds to a conserved GC-rich motif within the NR4A1 promoter, suppressing NR4A1 transcription and downstream p38 MAPK activation. Pharmacologic modulation of NR4A1 further confirmed its regulatory role in mediating KLF9-driven lipogenesis under IH. Conclusions: This study identifies KLF9 as a key transcriptional regulator driving IH-associated MASLD by repressing NR4A1 and inhibiting p38 MAPK signaling, thereby promoting hepatic lipogenesis. Targeting the KLF9–NR4A1 axis may offer a novel therapeutic approach for managing MASLD in patients with OSA and other hypoxia-related disorders.

29 August 2024 in PLOS ONE
Verified
Journal Article
Open access
PDF file
SYShang Yan
Shang Yan
GCGuowei Chen
Guowei Chen
NZNan Zeng
Nan Zeng
CGChaobing Gao
Chaobing Gao
Purpose: Button battery nasal impactions pose serious risks due to complications and the need for prompt removal, yet research on interventions remains limited due to its rare occurrence. To delineate the clinical manifestations of nasal foreign bodies associated with button batteries and to explore treatment approaches focused on minimizing the reliance on general anesthesia and surgical interventions. Methods: This study focuses on 176 cases of children who received treatment for nasal cavity button battery impactions. It encompasses various factors including age, gender, battery location, impaction duration, methods of extraction, and associated complications. Results: The incidence of nasal button battery cases among nasal foreign body instances was 1.16%, with a majority being males (60.23%) aged 1–5 years (98.29%). Utilizing a specially designed nasal foreign body hook and following established treatment protocols enabled the successful outpatient management of the majority of cases. Only 12 cases (6.82%) necessitated removal under general anesthesia due to management challenges in an outpatient setting. Furthermore, our findings indicated no linear correlation between the duration of battery retention and the risk of nasal septal perforation, which was observed in 31 cases (17.61%). Conclusion: Nasal foreign bodies caused by button batteries in children demand urgent attention due to their potentially grave outcomes. Our research is directed towards enhancing diagnostic and therapeutic strategies to bolster the success rates of outpatient removal, curtail the duration of foreign body retention, and diminish the reliance on general anesthesia.

1 November 2024
Verified
Journal Article
Closed access
XYXiaonan Yang
Xiaonan Yang
HHHongting Hua
Hongting Hua
DWDong Wang
Dong Wang
DSDongyu Si
Dongyu Si
RGRuijia Gan
Ruijia Gan
CGChaobing Gao
Chaobing Gao

17 December 2025 in Journal of Fluorescence
Verified
Journal Article
Closed access
PDF file
RGRuilin Ge
Ruilin Ge
RGRuijia Gan
Ruijia Gan
RGRongrong Guo
Rongrong Guo
Xiaowei XuXiaowei Xu
Xiaowei Xu
CGChaobing Gao
Chaobing Gao

6 June 2023 in Medical Science Monitor
Verified
Journal Article
Open access
NZNan Zeng
Nan Zeng
SYShang Yan
Shang Yan
QYQiong Yang
Qiong Yang
CGChaobing Gao
Chaobing Gao
Background: We explored a new method for measuring the length of artificial stapes during stapedotomy in otoendoscop-ic middle-ear surgery using a flexible ruler.Material/Methods: A retrospective analysis was conducted on 56 cases of otosclerosis, comprising 56 ears with a follow-up of over 6 months and complete data. Patients were admitted to the Department of Otology, Huazhong University of Science and Technology Union Shenzhen Hospital from July 2020 to June 2022. SPSS statistical software was used for efficacy analysis. The results of different measurement methods on the implantation time of the pros-thesis and postoperative hearing follow-up were compared.Results: The 56 patients were randomly divided into 2 groups. In 1 case measured by the metal measuring stick, the prosthesis was too short and was replaced during the operation; 2 patients experienced transient dizziness postoperatively, and the other patients had no surgical complications. All 56 patients had varying degrees of hearing improvement after surgery, and no dislocation of the ossicular chain was observed during the follow-up. There was a statistically significant difference in the implantation time of the prosthesis between the dif-ferent measurement methods (P<0.05). The improvement in hearing in the flexible ruler group was statistical-ly significant (P<0.05).Conclusions: The selection of the length of the ossicular prosthesis is a crucial step in the operation and can directly affect hearing outcomes. The use of a flexible ruler to measure prosthesis length can significantly shorten operation time and improve hearing, and the ruler is easily obtainable. It is worth promoting its application in ear endo-scopic stapedotomy.