Tomasz Sosnowski

Dr. Tomasz Sosnowski


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2011 in Infrared Physics & Technology
Verified
Journal Article
Closed access
RDR. Dulski
R. Dulski
TSTomasz Sosnowski
Tomasz Sosnowski
HPH. Polakowski
H. Polakowski

1 December 2014 in Metrology and Measurement Systems
Verified
Journal Article
Open access
MKMichał Krupiński
Michał Krupiński
GBGrzegorz Bieszczad
Grzegorz Bieszczad
TSTomasz Sosnowski
Tomasz Sosnowski
HMHenryk Madura
Henryk Madura
SGSławomir Gogler
Sławomir Gogler
In the article a non-uniformity correction method is presented which allows to compensate for the influence of detector’s temperature drift. For this purpose, dependency between output signal value and the temperature of the detector array was investigated. Additionally the influence of the temperature on the Offset and Gain coefficients was measured. Presented method utilizes estimated dependency between output signal of detectors and their temperature. In the presented method, the shutter is used for establishing signal reference. Thermoelectric cooler is used for changing the temperature of the detector array.

19 September 2017
Verified
Book Chapter
Closed access
PDF file
TSTomasz Sosnowski
Tomasz Sosnowski
GBGrzegorz Bieszczad
Grzegorz Bieszczad
HMHenryk Madura
Henryk Madura

1 May 2018
Verified
Conference Paper
Closed access
TSTomasz Sosnowski
Tomasz Sosnowski
GBGrzegorz Bieszczad
Grzegorz Bieszczad
HMHenryk Madura
Henryk Madura
MKMariusz Kastek
Mariusz Kastek

17 September 2009
Verified
Conference Paper
Closed access
PDF file
GBGrzegorz Bieszczad
Grzegorz Bieszczad
TOTomasz Orżanowski
Tomasz Orżanowski
TSTomasz Sosnowski
Tomasz Sosnowski
MKMariusz Kastek
Mariusz Kastek
A microbolometer is an uncooled thermal sensor of infra-red radiation. In thermal imaging, microbolometers organized in arrays called focal plane arrays (FPA) are used. Because of technological process microbolometric FPAs features unwanted detector gain and offset nonuniformity. Because of that, the detector matrix, being exposed to uniform infrared radiation produces nonuniform image with superimposed fixed pattern noise (FPN). To eliminate FPN, nonuniformity correction (NUC) algorithms are used. The offset of detector in array depends from mean temperature of FPA. Every single detector in matrix has its temperature drift, so the characteristic of every detector changes over temperature. To overpass this problem, a temperature stabilization of FPA is commonly used, however temperature stabilization is a relatively power demanding process. In this article a method of offset calculation and correction for every detector in array in function of mean array temperature is described. The method of offset temperature characteristic estimation is shown. The elaborated method let to use unstabilized microbolometric focal plane array in thermographic camera. Method of offset correction was evaluated for amorphous silicon based UL 03 04 1 detector array form ULIS.

31 January 2007 in Infrared Physics & Technology
Verified
Journal Article
Closed access
RDR. Dulski
R. Dulski
HMH. Madura
H. Madura
TPT. Piatkowski
T. Piatkowski
TSTomasz Sosnowski
Tomasz Sosnowski