Bartosz Kunka

Dr. Bartosz Kunka

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 October 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
GZGrzegorz Zurek
Grzegorz Zurek
MBMarek Binder
Marek Binder
Bartosz KunkaBartosz Kunka
Bartosz Kunka
RKRobert Kosikowski
Robert Kosikowski
MRMałgorzata Rodzeń
Małgorzata Rodzeń
JSJarosław Szczygieł
Jarosław Szczygieł
Background/Objectives: Developments in eye-tracking technology are opening up new possibilities for diagnosing patients in a state of minimal consciousness because they can provide information on visual behavior, and the movements of the eyeballs are correlated with the patients’ level of consciousness. The purpose of this study was to provide validation of a tool, based on eye tracking by comparing the results obtained with the assessment obtained using the Coma Recovery Scale-Revised (CRS-R). Methods: The mul-ti-center clinical trial was conducted in Poland in 2022–2023. The results of 46 patients who were not able to communicate verbally due to severe brain injury were analyzed in this study. The state of consciousness of patients was assessed using the Minimally Conscious State Detection test (MCSD), installed on an eye tracker and compared to CRS-R. The examinations consisted of performing the MCSD test on patients five times (T1–T5) within 14 days. Collected data were processed based on the FDA and GCP’s regulatory requirements. Depending on the nature of the data, the mean and standard deviation, median and lower and upper quartiles, and maximum and minimum values were calculated. Passing–Bablok regression analysis was used to assess the measurement equiva-lence of the methods used. Results: There was no difference between the MCSD and CRS-R in the raw change between T5 and T1 time points, as well as in the total % of points from all time points. The MCSD results from each time point show that at least the first two measurements serve to famil-iarize and adapt the patient to the measurement process, and the third and next measurement should be considered reliable. Conclusions: The results indicated a significant relationship be-tween the scores obtained with MCSD and CRS-R. The results suggest that it seems reasonable to introduce an assessment of the patient’s state of consciousness based on eye-tracking technology. The use of modern technology to assess a patient’s state of consciousness opens up the opportunity for greater objectivity, as well as a reduction in the workload of qualified personnel.

1 April 2012 in International Journal on Artificial Intelligence Tools
Verified
Journal Article
Closed access
Bartosz KunkaBartosz Kunka
Bartosz Kunka
Andrzej CzyzewskiAndrzej Czyzewski
Andrzej Czyzewski
AKAgnieszka Kwiatkowska
Agnieszka Kwiatkowska

1 January 2014
Verified
Book Chapter
Closed access
PDF file
Bartosz KunkaBartosz Kunka
Bartosz Kunka
TSTomasz Sanner
Tomasz Sanner
Andrzej CzyzewskiAndrzej Czyzewski
Andrzej Czyzewski
AKAgnieszka Kwiatkowska
Agnieszka Kwiatkowska

1 January 2014 in Lecture Notes in Computer Science
Verified
Book Chapter
Closed access
PDF file
Bartosz KunkaBartosz Kunka
Bartosz Kunka
AKAdam Korzeniewski
Adam Korzeniewski
BKBożena Kostek
Bożena Kostek
Andrzej CzyzewskiAndrzej Czyzewski
Andrzej Czyzewski