Background and Objectives: Plantar fasciitis is one of the most common foot pathologies, and its diagnosis and clinical follow-up increasingly rely on the use of ultrasound. The aim of this study is to compare the reliability of ultrasound measurements of plantar fascia thickness between an expert technician, with more than 5 years of ultrasound experience, and a novice technician, with no prior ultrasound experience—both of whom are podiatrists. This allows us to assess whether operator experience significantly influences the results. Methods: An observational, descriptive, and cross-sectional study was designed with a sample of 60 healthy patients aged between 20 and 32 years. The thickness of the plantar fascia in both feet was measured using ultrasound. Each patient was evaluated by two observers (one expert and one novice) using a Vinno E35 ultrasound machine. Results: The results of the analysis indicated that there were no statistically significant differences in the measurements obtained either between the two technicians or between the left and right feet of the same individual, as the calculated p-value in both cases was greater than the conventional threshold of 0.05. This suggests that the measurements were consistent regardless of the operator or the side being evaluated. Nevertheless, when examining the differences in the time required to measure the plantar fascia between the two technicians, the situation was different. In this case, the data distribution did not meet the assumption of normality, as evidenced (p-value of less than 0.001). Furthermore, it was observed that the experienced technician not only completed the measurements in a shorter amount of time but also demonstrated less variability in those times, indicating a more efficient and standardized approach to the procedure. In contrast, the novice technician initially took longer and exhibited greater inconsistency; however, as the study progressed, a noticeable and progressive learning effect became apparent. Specifically, from approximately the midpoint of the study onward, the novice technician showed a significant improvement, achieving faster and more consistent measurement times compared to the earlier stages of the research. Conclusions: The study demonstrates that ultrasound measurements of the plantar fascia are consistent between technicians. However, the expert technician performs the measurements with greater speed and precision, and a learning effect is evident in the novice technician.
This study aimed to explore interobserver differences, intraobserver consistency, and temporal changes in ultrasound-based plantar fascia thickness measurements between an experienced musculoskeletal sonographer and a student examiner. Additionally, the study described the student’s longitudinal progression during the measurement acquisition period under supervised conditions. Materials and Methods: This cross-sectional, descriptive observational study included 84 adults, of whom 42 presented plantar fasciopathy and 42 had no history of heel pain. All participants underwent ultrasound assessment of plantar fascia thickness performed by two observers—a novice student and an expert examiner—each obtaining two measurements per participant. Statistical analyses focused on detecting differences between observers and temporal changes in measurement performance. Intraclass Correlation Coefficients (ICCs) were calculated to further explore agreement. Results: In the overall analysis, no statistically significant differences were detected at the group level between student and expert measurements. However, when analyses were stratified by time periods, statistically significant differences were observed during the initial phase (November–December 2024; p = 0.026). These differences were no longer consistently detected in subsequent periods. Additionally, interobserver agreement appeared to increase over time; however, this observation is purely descriptive and should be interpreted with caution, as no formal comparisons between ICC estimates were performed and confidence intervals overlap. Conclusions: These findings suggest a progressive reduction in measurement differences between observers over time, consistent with a learning-related effect. However, the results should be interpreted as exploratory and do not constitute evidence of formal interobserver reliability. The findings highlight the potential importance of structured ultrasound training and supervised practice in improving agreement between observers in both clinical and educational settings.