WeiJia Li

Mr. WeiJia Li


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 May 2025 in Photonics
Verified
Journal Article
Open access
PDF file
XZXie Zhitao
Xie Zhitao
GLGuanyu Lin
Guanyu Lin
WJWang Jianing
Wang Jianing
XWXi Wang
Xi Wang
WLWeiJia Li
WeiJia Li
KHKong Hengyuan
Kong Hengyuan
As the signature gas released before coal combustion, methane’s telemetry accuracy is susceptible to environmental influences, which is a difficult problem that needs to be solved. This article provides a detailed exposition on the application of Tunable Diode Laser Absorption Spectroscopy (TDLAS) technology in the field of gas monitoring, with particular emphasis on its advantages in coal safety detection. The coal combustion experiment is conducted to determine the required performance indexes. Through the temperature compensation algorithm and normalized signals, the impact of factors such as ambient temperature and environmental noise is reduced, effectively improving the signal-to-noise ratio and accuracy. The experiments demonstrate that this system effectively lowers the detection limit for methane while improving measurement accuracy, thereby providing robust support for the early warning of coal spontaneous combustion.

31 January 2025 in Sensors
Verified
Journal Article
Open access
PDF file
WLWeiJia Li
WeiJia Li
GLGuanyu Lin
Guanyu Lin
WJWang Jianing
Wang Jianing
JLJifeng Li
Jifeng Li
YSYulai Sun
Yulai Sun
ZBZhibin Ban
Zhibin Ban
To facilitate the effective assessment of respiratory entropy during poultry breeding, a novel oxygen (O2) and carbon dioxide (CO2) sensor was developed based on the off−axis integrated cavity output spectroscopy technique, featuring effective absorption optical paths of 15.5 m and 8.5 m, respectively. The sensor employs integrated environmental control technology, substantially enhancing detection precision. To improve the instrument’s response speed, the miniaturization of the cavity and structural optimization were implemented, achieving a rapid response time of merely 6.22 s, addressing the stringent requirements for quick responsiveness in poultry respiration thermometry research. A signal processing model tailored for on−site applications was designed, boosting the system’s signal−to−noise ratio by 4.7 times under complex environmental noise conditions. Utilizing Allan variance analysis, the sensor’s detection limits for O2 and CO2 were ascertained to be 2.9 ppm and 7.4 ppb, respectively. A 24−h field application test conducted in Gongzhuling demonstrated that the sensor’s results align with the respiratory characteristics of poultry under normal physiological conditions, validating its extensive potential for application in respiratory analysis, environmental monitoring, and industrial sectors.