This study assessed the performance of different remotely sensed soil moisture products with in situ observations; six profile probes for the water content monitoring were selected, operating during 2016–2021 from the Voineşti Experimental Basin in the Romanian Subcarpathian region. The reliability of satellite observations has been analyzed on both single ground-based observation points and spatialized information, considering near-surface and root-zone soil moisture data. The physics-based index (HCI) and some statistical tests widely used in inter-comparison analyses have been computed. The study of HCI highlighted that the SMAP SP_L4_SM products have shown the best performances considering the near-surface and root-zone data evaluations. The comparison of SWI1km observations with in situ data produced good results for single-point and spatialized soil moisture estimations acquired at different depths over the experimental basin. The SSM1km and SMAP L2_SM_SP products exhibited the lowest performances. The results contribute to the validation of satellite products of surface and root-zone soil moisture in the Subcarpathian region, helping to provide information in an area not monitored by the International Soil Moisture Network. The findings offer valuable insights into evaluating the performance of satellite soil moisture products in the Romanian region.
Almost all multipurpose reservoirs in Romania were put into operation 30–50 years ago or even earlier. Meanwhile, a large volume of hydrologic data has been collected, and the initial design flood should be reconsidered. Consequently, the operating rules of flow control structures (bottom gates and weir gates) should be re-examined, mainly for medium and low-frequency floods. The design flood is not unique, being characterized by different shapes and time to peak, which has consequences for flood mitigation rules. Identifying the critical design flood is an important preliminary step, although it is usually neglected in flood management. Simulating the operation of the Stânca–Costești reservoir on the Prut River, it was found that the design flood corresponding to the maximum value of the compactness coefficient is the most difficult to mitigate considering the specific conditions of the dam and the reservoir: the prescribed conservation level in the reservoir, and the design flood volume of medium and rare floods that far exceeds the flood control volume. These conditions can jeopardize both dam safety and downstream flood protection. The main steps of the proposed approach are as follows: (1) developing the hydraulic model; (2) statistical processing of the registered floods and defining critical design floods for different AEPs (Annual Exceedance Probabilities); (3) deriving optimal operation rules based on a simulation-optimization model; (4) implementing real-time adaptive operation of the mechanical outlets; and (5) critically assessing the operating rules after the event. Based on the hydrological forecast, if necessary, new outlets are put into operation while keeping the ones already activated. Based on the hydrological forecast and properly operated, the safety of the Stânca–Costești dam is guaranteed even in the event of a 0.1% CC (Climate Change) flood. However, for floods greater than 1% magnitude, the carrying capacity of the downstream riverbed is exceeded. The main gaps addressed in this paper are the following: (1) the establishment of critical design floods, and (2) the adaptive operating rules of outlet devices aimed at optimizing flood control results, using short-term flood forecasts.