Compact and robust optical clocks are significant in scientific research and engineering. Here, we present a physical system for a strontium atomic optical clock with dimensions of 465 mm × 588 mm × 415 mm and a weight of 66.6 kg. To date, this is one of the most compact physical systems ever reported. The application of the magnetic shielding box in this physical system allowed the effect of external magnetic field fluctuation on cold atoms to be negligible. The physical system passed rigorous environmental tests and remained operational. A wavelength meter integrated in this physical system could monitor the wavelengths of the incident laser, and it could automatically calibrate the wavelengths of all lasers using a microcomputer. This compact and robust physical system could be a hardware basis for demonstrating a portable optical clock or even a space optical clock.
In this paper, the magic wavelength of the 87Sr optical lattice clock is determined by a method that bypasses the need for lattice trap depth modulation. Instead, it relies on an additional AC Stark shift generated by a dipole beam operating near the frequency of the lattice light and oriented perpendicular to the optical lattice. The magic wavelength is inferred by measuring the AC Stark shift induced by the dipole beam as a function of its power under various frequency detunings. The effect of the dipole beam on the external states of the cold ensemble is evaluated through comparative analysis of the radial and axial sideband spectra, both with and without the dipole beam. Variations in density shift resulting from changes in external states are evaluated using comprehensive numerical calculations. By avoiding trap depth modulation, this method effectively suppresses the influence of the density shift, thereby offering a promising avenue for accurately determining the magic wavelength.
We propose a method that enables precise determination of the number of atoms in a Dick-noise-free optical lattice clock, by effectively addressing quantum projection noise. Our approach relies on conducting stability measurements at three distinct parameter sets, allowing us to differentiate between quantum projection noise, photon shot noise, and technical noise. Importantly, our method enables accurate extraction of the atom number, even in the presence of photon shot noise and technical noise. To validate the effectiveness of our approach, we employ numerical simulations and optimize the modulation parameters to achieve the smallest uncertainty possible. The numerical simulations show the validity of our method and demonstrate a measurement uncertainty in the atom number that is below 4% across a wide range of atom numbers, provided that the standard deviation of atom number fluctuation is kept below 0.23 times the average atom number.
We propose a method that enables the precise determination of the number of atoms in a Dick-noise-free optical lattice clock, by effectively addressing quantum projection noise. Our approach relies on conducting stability measurements at three distinct parameter sets, allowing us to differentiate between quantum projection noise, photon shot noise, and technical noise. Importantly, it enables accurate extraction of the atom number, even in the presence of photon shot noise and technical noise. We utilize numerical simulations to validate our approach, optimize the modulation parameters for minimal uncertainty, and investigate the impact of atom number fluctuations on the determinacy of our results. The numerical results show the validity of our method and demonstrate an estimated uncertainty in the atom number that is below 4% with 6.7 h measurement, provided that the standard deviation of atom number fluctuation is kept below 0.14 times the average atom number.