PORNPUN JARATSING

Dr. PORNPUN JARATSING

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
SASupatra Areekit
Supatra Areekit
PTPongbun Tangjitrungrot
Pongbun Tangjitrungrot
SKSintawee Khuchareontaworn
Sintawee Khuchareontaworn
KRKankanit Rattanathanawan
Kankanit Rattanathanawan
PJPORNPUN JARATSING
PORNPUN JARATSING
KCKosum Chansiri
Kosum Chansiri
Porcine epidemic diarrhea virus (PEDV) and porcine circovirus type 2 (PCV2) are both important global pathogenic viruses which have a significant impact on the swine industry. In this study, a duplex loop-mediated isothermal amplification (duplex LAMP) method was developed in combination with lateral flow dipstick (LFD) for simultaneous detection of PEDV and PCV2 using specific sets of primers and probes designed based on the conserved regions of a spike gene (KF272920) and an ORF gene (EF493839), respectively. The limit of detection (LOD) values of the duplex LAMP-LFD for the detection of PEDV and PCV2 were 0.1 ng/µL and 0.246 ng/µL, respectively. The LOD of duplex LAMP-LFD was 10-times more sensitive than conventional PCR and RT-PCR-agarose gel-electrophoresis (PCR-AGE and RT-PCR-AGE). No cross-reaction to each other and to other pathogenic viruses that can infect pigs were observed according to analytical specificity tests. The duplex LAMP-LFD method for the simultaneous detection of PEDV and PCV2 co-infection could be completed within approximately 1.5 h, and only a simple heating block was required for isothermal amplification. The preliminary validation using 50 swine clinical samples with positive and negative PEDV and/or PCV2 revealed that the sensitivity, specificity, and accuracy of duplex LAMP-LFD were all 100% in comparison to conventional PCR and RT-PCR. Hence, this study suggests that duplex LAMP-LFD is a promising tool for the early detection and initial screening of PEDV and PCV2, which could be beneficial for prevention, planning, and epidemiological surveys of these diseases.

31 October 2024 in Pathogens
Verified
Journal Article
Open access
PDF file
SPSaranthum Phurijaruyangkun
Saranthum Phurijaruyangkun
PTPongbun Tangjitrungrot
Pongbun Tangjitrungrot
PJPORNPUN JARATSING
PORNPUN JARATSING
SASuphitcha Augkarawaritsawong
Suphitcha Augkarawaritsawong
KKKhurawan Kumkrong
Khurawan Kumkrong
SSSomchai Santiwatanakul
Somchai Santiwatanakul
Treponema pallidum subspp. pallidum is a spirochaete bacterium that causes syphilis, one of the most common sexually transmitted diseases. Syphilis progresses through four distinct stages, each characterized by specific symptoms, namely primary, secondary, latent, and late (tertiary) syphilis. Serology has been considered the primary diagnostic approach. However, it is plagued by problems such as the limited specificity of nontreponemal tests and the inadequate correlation of treponemal tests with disease activity. In this study, we focused on the development of a loop-mediated isothermal amplification assay utilizing hydroxy naphthol blue (LAMP-HNB) for the diagnosis of T. pallidum subspp. pallidum. Specifically, this study seeks to determine the analytical sensitivity (limit of detection; LOD) and analytical specificity. Four hundred clinical serum samples were analyzed for diagnostic sensitivity, specificity, and predictive value, and each technique’s 95% confidence intervals (95% CI, p < 0.05) were evaluated. The limit of detection for polymerase chain reaction with agarose gel electrophoresis (PCR-AGE), the loop-mediated isothermal amplification assay combined with agarose gel electrophoresis (LAMP-AGE), and LAMP-HNB were 116 pg/µL, 11.6 pg/µL, and 11.6 pg/ µL, respectively. Analytical specificity examinations indicated the absence of cross-reactivity with Leptospira interrogans, Staphylococcus aureus, Enterococcus faecalis, Escherichia coli, Klebsiella pneumoniae, Acinetobacter baumannii, Pseudomonas aeruginosa, human immunodeficiency virus (HIV), and healthy human serum in PCR-AGE, LAMP-AGE, and LAMP-HNB. The diagnostic sensitivity, diagnostic specificity, positive predictive value (PPV), and negative predictive value (NPV) for PCR-AGE were 100.00 (100.00)%, 94.50 (94.40–94.60)%, 94.79 (94.69–94.88)%, and 100.00 (100.00)%, respectively. While, for LAMP-AGE and LAMP-HNB, they were 100.00 (100.00)%, 91.00 (90.87–91.13)%, 91.74 (91.63–91.86)%, and 100.00 (100.00)%, respectively. The LAMP-HNB test is simple, rapid, highly sensitive, and highly specific, without requiring expensive equipment. In the future, the LAMP-HNB assay may develop into a single-step diagnostic process, enabling the use as point-of-care testing for the diagnosis, prevention, and management of syphilis infection.

18 October 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
SPSaranthum Phurijaruyangkun
Saranthum Phurijaruyangkun
PTPongbun Tangjitrungrot
Pongbun Tangjitrungrot
PJPORNPUN JARATSING
PORNPUN JARATSING
SASuphitcha Augkarawaritsawong
Suphitcha Augkarawaritsawong
SPSAWANYA - PONGPARIT
SAWANYA - PONGPARIT
SSSomchai Santiwatanakul
Somchai Santiwatanakul
Background: Venereal syphilis in humans is caused by Trepenoma pallidum subspp. pallidum. A study has shown that 30,302 individuals in Thailand had syphilis in 2020, with a male-to-female ratio of 1:0.8 and the highest incidence rate at ages between fifteen and twenty-four. Methods: This research aimed to develop a loop-mediated isothermal amplification assay using gold nanoparticles (LAMP-AuNPs). Analytical sensitivity, diagnostic specificity, accuracy, and predictive values for each technique are provided. Results: The diagnosis sensitivities of polymerase chain reaction using agarose gel electrophoresis (PCR-AGE), loop-mediated isothermal amplification assay using agarose gel electrophoresis (LAMP-AGE), and LAMP-AuNPs were 116 ng/µL, 11.6 ng/µL, and 11.6 ng/µL, respectively. We evaluated the analytical specificity using PCR and a LAMP-based assay, and there was no cross-reactivity to Leptospira interrogans, Staphylococcus aureus, Enterococcus faecalis, Escherichia coli, Klebsiella pneumoniae, Acinetobacter baumannii, Pseudomonas aeruginosa, human immunodeficiency virus (HIV), and healthy humans. After analyzing 400 serum samples of patients suspected of syphilis, the LAMP-AGE and LAMP-AuNPs assays displayed 100% diagnostic sensitivity scores, 91% diagnostic specificity scores, 95.5% accuracy rates, 100% positive predictive values (PPVs), and 91% negative predictive values (NPVs), the positive likelihood ratio (LR+) was 11.11, while the negative likelihood ratio (LR−) was 0. Conversely, for PCR assays displayed 100% diagnostic sensitivity scores, 94.5% diagnostic specificity scores, 97.25% accuracy rates, 100% PPVs, and 94.5% NPVs, LR+ was 18.18, and LR− was 0. Conclusions: The LAMP-AuNPs technique demonstrates rapidity, affordability, and convenience, rendering it well-suited for point-of-care applications in the diagnosis, prevention, and management of pathogenic infections.

22 July 2025 in The Microbe
Verified
Journal Article
Open access
MYMontri Yasawong
Montri Yasawong
MPManassanan Phatcharaharikarn
Manassanan Phatcharaharikarn
TSThunwarat Songngamsuk
Thunwarat Songngamsuk
PSParweenuch Santaweesuk
Parweenuch Santaweesuk
PWPrapimpun Wongchitrat
Prapimpun Wongchitrat
SASupatra Areekit
Supatra Areekit

Verified
Journal Article
Open access
PDF file
SPSaranthum Phurijaruyangkun
Saranthum Phurijaruyangkun
PTPongbun Tangjitrungrot
Pongbun Tangjitrungrot
KCKantima Choosang
Kantima Choosang
ABAdun Bunchaleamchai
Adun Bunchaleamchai
NWNaiyana Wattanakul
Naiyana Wattanakul
SPSAWANYA - PONGPARIT
SAWANYA - PONGPARIT
Carbapenem-resistant Acinetobacter baumannii (CRAB) is a major cause of hospital-acquired infections. Conventional phenotyping for carbapenem resistance requires more than 24 h, which delays clinical decisions and increases the risk of outbreaks. This study aims to develop a lateral flow dipstick (LFD) assay that detects loop-mediated isothermal amplification (LAMP) products targeting the blaOXA-23-like gene, providing results within 1–1.5 h. Primer specificity was evaluated using seven Gram-positive and nine Gram-negative species commonly present in clinical samples, as well as carbapenem-susceptible A. baumannii and CRAB isolates harboring other resistance genes. The assay detected the blaOXA-23-like gene at concentrations as low as 1.57 pg/µL, demonstrating ~10-fold greater sensitivity than conventional PCR. The gene was present in 224/268 CRAB samples (83.6%) and absent in 100 carbapenem-susceptible A. baumannii samples. Results were fully concordant with PCR, yielding 100% sensitivity and specificity. The method requires no expensive or complex instrumentation. Future studies should validate the assay across multiple hospitals and clinical specimens to confirm its generalizability and clinical utility. Multiplex LAMP with dual LFD readouts could also enable simultaneous detection of additional carbapenem resistance genes, supporting rapid CRAB surveillance and outbreak control.

Verified
Journal Article
Open access
PDF file
SPSaranthum Phurijaruyangkun
Saranthum Phurijaruyangkun
PTPongbun Tangjitrungrot
Pongbun Tangjitrungrot
SPSAWANYA - PONGPARIT
SAWANYA - PONGPARIT
NWNaiyana Wattanakul
Naiyana Wattanakul
BJBajaree Jantrapanukorn
Bajaree Jantrapanukorn
KCKosum Chansiri
Kosum Chansiri
Vancomycin-resistant enterococci (VRE) have emerged as major nosocomial pathogens worldwide, primarily due to the acquisition of the vanA gene, which confers high-level resistance to vancomycin. Rapid detection of the vanA gene, which is associated with vancomycin resistance, is crucial for timely clinical management and infection control. Through this research, we aimed to develop an assay combining loop-mediated isothermal amplification and a lateral flow Dipstick (LAMP-LFD) for the rapid detection of the vanA gene in VRE. Genomic DNA was extracted and amplified from 100 clinical urine samples by LAMP targeting vanA under optimized, constant-temperature conditions, with the amplified product then detected using a lateral flow Dipstick assay based on probe pairing. The diagnostic performance of the LAMP-LFD method was evaluated and compared with a conventional PCR reference method. The LAMP-LFD assay successfully detected the vanA gene in all positive samples, with negative samples showing no assay cross-reactivity with 12 species of bacteria commonly found in clinical settings. The developed LAMP–LFD assay showed promising diagnostic performance for detecting the vanA gene in Enterococcus isolates, demonstrating complete agreement with the reference PCR method in this study. Owing to its rapid turnaround time, simplicity, and visual readout, the assay has potential as a molecular screening tool for VRE. However, further validation in larger, multicenter studies and comparison with phenotypic antimicrobial susceptibility testing are required before routine clinical implementation.