Felicitas Mayinger

Dr. Felicitas Mayinger

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 November 2022 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
VGVeronika Greil
Veronika Greil
FMFelicitas Mayinger
Felicitas Mayinger
MRMarcel Reymus
Marcel Reymus
BSBogna Stawarczyk
Bogna Stawarczyk

1 July 2021 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
LSLisa Marie Schönhoff
Lisa Marie Schönhoff
FMFelicitas Mayinger
Felicitas Mayinger
MEMarlis Eichberger
Marlis Eichberger
ERElena Reznikova
Elena Reznikova
Bogna StawarczykBogna Stawarczyk
Bogna Stawarczyk

16 October 2020 in Clinical Oral Investigations
Verified
Journal Article
Open access
PDF file
FMFelicitas Mayinger
Felicitas Mayinger
DMDanka Micovic
Danka Micovic
ASAndreas Schleich
Andreas Schleich
MRMalgorzata Roos
Malgorzata Roos
MEMarlis Eichberger
Marlis Eichberger
BSBogna Stawarczyk
Bogna Stawarczyk
Objectives: To examine the retention force of removable dental prosthesis (RDP) clasps made from polyetheretherketone (PEEK) and cobalt-chrome-molybdenum (CoCrMo, control group) after storage in water and artificial aging. Materials and methods: For each material, 15 Bonwill clasps with retentive buccal and reciprocal lingual arms situated between the second pre- and first molar were manufactured by milling (Dentokeep [PEEKmilled1], NT digital implant technology; breCAM BioHPP Blank [PEEKmilled2], bredent), pressing (BioHPP Granulat for 2 press [PEEKpressed], bredent), or casting (remanium GM 800+ [CoCrMo], Dentaurum); N = 60, n = 15/subgroup. A total of 50 retention force measurements were performed for each specimen per aging level (initial; after storage [30 days, 37 °C] and 10,000 thermal cycles; after storage [60 days, 37 °C] and 20,000 thermal cycles) in a pull-off test. Data were statistically analyzed using one-way ANOVA, post hoc Scheffé and mixed models (p < 0.05). Results: Initial, PEEKpressed (80.2 ± 35.2) and PEEKmilled1 (98.9 ± 40.3) presented the lowest results, while PEEKmilled2 (170.2 ± 51.8) showed the highest values. After artificial aging, the highest retention force was observed for the control group (131.4 ± 56.8). The influence of artificial aging was significantly higher for PEEK-based materials. While PEEKmilled2 and PEEKpressed showed an initial decline in retention force, all other groups presented no impact or an increase in retention force over a repetitive insertion and removal of the clasps. Conclusions: Within the tested PEEK materials, PEEKmilled2 presented superior results than PEEKpressed. Although CoCrMo showed higher values after artificial aging, all materials exhibited sufficient retention to recommend usage under clinical conditions. Clinical relevance: As RDPs are still employed for a wide range of indications, esthetic alternatives to conventional CoCrMo clasps are sought.

10 November 2023 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
VGVeronika Geiger
Veronika Geiger
FMFelicitas Mayinger
Felicitas Mayinger
MHMoritz Hoffmann
Moritz Hoffmann
MRMarcel Reymus
Marcel Reymus
Bogna StawarczykBogna Stawarczyk
Bogna Stawarczyk

7 October 2020 in Clinical Oral Investigations
Verified
Journal Article
Open access
PDF file
DMDanka Micovic
Danka Micovic
FMFelicitas Mayinger
Felicitas Mayinger
SBSebastian Bauer
Sebastian Bauer
MRMalgorzata Roos
Malgorzata Roos
MEMarlis Eichberger
Marlis Eichberger
BSBogna Stawarczyk
Bogna Stawarczyk
Objectives: To investigate the retention force of polyetheretherketone (PEEK) removable dental prosthesis clasps in comparison with a cobalt-chrome-molybdenum control group after storage in artificial saliva. Materials and Methods: Clasps were milled (Dentokeep (PEEKmilled1), NT digital implant technology; breCAM BioHPP Blank (PEEKmilled2), bredent), pressed (BioHPP Granulat for 2 press (PEEKpressed), bredent), or cast (remanium GM 800+ (cobalt-chrome-molybdenum), Dentaurum); N = 60, n = 15/subgroup. Retention force was examined 50 times/specimen in a pull-off test using the universal testing machine (Zwick 1445), where pull-off force was applied with a crosshead speed of 5 mm/minute until the maximum force dropped by 10%, at different aging levels: (1) initial, after storage in artificial saliva for (2) 90 and (3) 180 days. Statistical analysis was performed using one-way ANOVA followed by post hoc Scheffé-test and mixed models (p < 0.05). Results: Cobalt-chrome-molybdenum presented the highest retention force. No differences were observed between polyetheretherketone materials. Cobalt-chrome-molybdenum showed a significant decrease of its values after artificial aging, while polyetheretherketone materials presented similar results over the course of aging. Regarding a repetitive insertion and removal, even though PEEKmilled2 and cobalt-chrome-molybdenum showed an initial increase, ultimately, a decrease in retention force was observed for all tested groups. Conclusions: Although the control group showed significantly higher results, the retention force of polyetheretherketone materials indicate a potential clinical application. Neither the manufacturing process nor artificial aging showed an impact on the retention force of polyetheretherketone clasps. Clinical relevance: Mechanical properties of novel removable dental prosthesis clasp materials devised to meet the growing esthetic demands of patients need to be investigated to ensure a successful long-term clinical application.

15 July 2022 in Clinical Oral Investigations
Verified
Journal Article
Open access
PDF file
FMFelicitas Mayinger
Felicitas Mayinger
RBRamona Buser
Ramona Buser
MLMaximilian Laier
Maximilian Laier
LSLisa Marie Schönhoff
Lisa Marie Schönhoff
MKMatthias Kelch
Matthias Kelch
BSBogna Stawarczyk
Bogna Stawarczyk
Objectives: The aim of this study is to investigate the influence of the material and corresponding sintering protocol, layer thickness, and aging on the two-body wear (2BW) and fracture load (FL) of 4Y-TZP crowns. Materials and methods: Multi-layer 4Y-TZP crowns in three thicknesses (0.5 mm/1.0 mm/1.5 mm) were sintered by high-speed (Zolid RS) or conventional (Zolid Gen-X) sintering. 2BW of ceramic and enamel antagonist after aging (1,200,000 mechanical-, 6000 thermal-cycles) was determined by 3D-scanning before and after aging and subsequent matching to determine volume and height loss (6 subgroups, n = 16/subgroup). FL was examined initially and after aging (12 subgroups, n = 16/subgroup). Fractographic analyses were performed using light-microscope imaging. Global univariate analysis of variance, one-way ANOVA, linear regression, Spearman’s correlation, Kolgomorov–Smirnov, Mann–Whitney U, and t test were computed (alpha = 0.05). Weibull moduli were determined. Fracture types were analyzed using Ciba Geigy table. Results: Material/sintering protocol did not influence 2BW (crowns: p = 0.908, antagonists: p = 0.059). High-speed sintered Zolid RS presented similar (p = 0.325–0.633) or reduced (p < 0.001–0.047) FL as Zolid Gen-X. Both 4Y-TZPs showed an increased FL with an increasing thickness (0.5(797.3–1429 N) < 1.0(2087–2634 N) < 1.5(2683–3715 N)mm; p < 0.001). For most groups, aging negatively impacted FL (p < 0.001–0.002). Five 0.5 mm specimens fractured, four showed cracks during and after aging. Conclusions: High-speed sintered crowns with a minimum thickness of 1.0 mm showed sufficient mechanical properties to withstand masticatory forces, even after a simulated aging period of 5 years. Clinical relevance: Despite the manufacturer indicating a thickness of 0.5 mm to be suitable for single crowns, a minimum thickness of 1.0 mm should be used to ensure long-term satisfactory results.