This study investigates the impact of embedded voltage source converter‐based high voltage direct current (VSC‐HVDC) links on AC grids transient stability. Firstly, using transient energy functions, it is demonstrated that VSC‐HVDC links controlled to track constant power references, do not inherently improve transient stability of the surrounding AC grid as an AC line naturally does. Then, a control law using the feedback linearisation technique on a simple but representative power system is derived. The control law highlights and combines the three main actions the VSC‐HVDC link can offer to enhance rotor angle stability: fast power reallocation, injection of synchronising power and injection of damping power. The control law is implemented and validated in EMT simulation. It is then shown that an HVDC link can assure the synchronisation of different AC areas even if no AC transmission lines interconnect them. Through another case study, it is shown how the HVDC link can help to share dynamic frequency reserves to not jeopardise the stability of the system. The last example investigates the effect of a DC fault on AC transient stability and how the control can help improving the system response.
13 October 2020 in IEEE Transactions on Power Systems
This paper presents a distributed supplementary control for embedded Multi-Terminal VSC-HVDC (MTDC) grids to enhance transient stability of the surrounding AC grid. Firstly, the need of supplementary controllers for embedded MTDC grids is demonstrated via the study of the Transient Energy Functions (TEF) of a simple hybrid AC/DC power system. Then, the proposed control structure is presented. The control aims to enhance the rotor angle stability of the surrounding AC system via the modulation of the active power of the converters. The objective of the control is to enhance transient stability while keeping the zero power balance of the DC grid even if converters reach their active power limits. The proposed control uses frequency and angle measurements only at the Point of Common Coupling (PCC) of the converters. The idea behind this structure is to match the control actions and limits of each pair (i, j) of converters. If converter i modulates its power, converter j modulates the same amount of power in the opposite direction. The concept of virtual links is used in this paper to represent this matching. Finally, the proposed controller is tested on a modified version of the IEEE 39 bus system using EMT simulations.
Massive off-shore wind integration in the European power system, the necessity to increase the power flows between asynchronous areas and inside continental Europe, call for HVDC transmission development, and multi-terminal-HVDC-based transmission. HVDC technology is highly controllable, but also sensitive to faults and degraded modes. Achieving an efficient and robust AC/DC transmission system requires to develop a vision of HVDC role and functionalities in different situations. In addition to HVDC converter core control functions and DC grid protection strategies, a coordinated DC grid control layer is beneficial to supervise control modes towards overall AC/DC transmission system security and stability, as well as to ensure converter controls interoperability. This paper offers a vision of what a robust AC / DC network can be, based on control and protection strategies that can be implemented via HVDC converter capabilities.
In recent years, different protection strategies for high‐voltage direct current (HVDC) grids have been developed by the industry and academia for the reliable and safe operation of direct current grids. The proposed strategies have different impacts on the AC networks where HVDC grids are connected. In the case of embedded HVDC grids embedded in a synchronous AC network, a partial loss of the HVDC grid might cause the desynchronisation of the AC grid. Therefore, it is of utmost importance to assess the impact of those protection strategies into the stability of the whole network. The objective of this study is to propose a methodology for the transient stability assessment of a simple but representative AC grid in case of DC fault. After validation of the methodology, some HVDC link protection criteria are defined in terms of the Critical Time to Return to Operation. These criteria will be helpful for the design of HVDC protection systems or for the sizing of future HVDC links in order to respect the constraints of the existing protection strategies.
10 April 2024 in IEEE Transactions on Power Electronics
This letter first identifies a new mode of low-frequency harmonic instability when combining grid-forming control with the typical dc voltage droop control necessitated in multiterminal high voltage direct-current transmissions. This mode does not exist when grid-following control is applied and its mechanism is explicitly revealed by the dc-side input admittance modeling of the converter. Then, a phase compensator plus a virtual power system stabilizer are introduced to pacify the input admittance within the critical frequency range and derisk the related instability. Last, it is also demonstrated that the proposed control strategy achieves excellent performance in contingent active power imbalance ride-through in the dc system. All the analyses are verified by electro-magnetic-transient simulations with a modular multilevel converter model comprising 278 submodules per arm.