The aim of this study was to evaluate the performance of two forms of basic granular activated carbon (GAC), mineral (pH = 10.5) and vegetal (pH = 9), for the removal of three pharmaceuticals, as sulphamethoxazole (SMX), diclofenac (DCF) and 17β-estradiol (E2), from two different matrices: fortified distilled (2.4–3.0 mg L−1 and pH from 5.5 to 6.5) and natural (∼1.0 mg L−1 and pH from 7.1 to 7.2) water in a bench scale. The Rapid Small-Scale Column Test used to assess the ability of mineral and vegetal GAC on removal of such pharmaceuticals led to removal capacities varying from 14.9 to 23.5 mg g−1 for E2, from 23.7 to 24.2 mg g−1 for DCF and from 20.5 to 20.6 mg g−1 for SMX. Removal efficiencies of 71%, 88% and 74% for DCF, SMX and E2, respectively, were obtained at breakthrough point when using mineral GAC, whereas for the vegetal GAC the figures were 76%, 77% and 65%, respectively. The carbon usage rate at the breakthrough point varied from 11.9 to 14.5 L g−1 for mineral GAC and from 8.8 to 14.8 L g−1 for vegetal GAC. Mineral CAG also exhibited the best performance when treating fortified natural water, since nearly complete removal was observed for all contaminants in the column operated for 22 h at a carbon usage rate of 2.9 L g−1.
1 October 2019 in Engenharia Sanitaria e Ambiental
RESUMO O cerne do presente trabalho consistiu em aplicar ferramentas de análise exploratória multivariada objetivando avaliar o número de estações de monitoramento de qualidade da água e a frequência de amostragem. Para tal, utilizou-se banco de dados disponibilizado pelo Instituto Mineiro de Gestão das Águas (IGAM) referente à Bacia do Rio das Velhas, na região central mais populosa de Minas Gerais. Foram utilizadas as técnicas de análise das componentes principais (ACP) e a rede neural de Kohonen, que culminaram na significativa redução da frequência de amostragem, em alguns casos de mensal para anual ou semestral, e na redução do número de estações de monitoramento de 36 para 33. Os resultados permitem abrir a possibilidade do emprego dos métodos utilizados como ferramentas de gestão de recursos hídricos de bacias hidrográficas visando à otimização dos programas de monitoramento de qualidade de água.
1 November 2023 in Revista de Gestão Social e Ambiental
Purpose: To evaluate the production of concrete from the partial replacement of Portland cement with petroleum catalyst residue (RC), generated in large quantities by the petrochemical industries, and the addition of polyethylene glycol 400 (PEG 400), with an emphasis on investigating its mechanical properties and durability, considering the technological, scientific and environmental aspects. Theoretical framework: Oil catalyst waste is generated in significant quantities and is classified as non-inert due to its metal ion content, so there is a need to investigate new disposal methods. The use of RC as partial substitute for Portland cement, with the addition of PEG 400 (self-curing agent), was investigated for the production of non-conventional concrete. The waste has pozzolanic activity, enabling improvements in mechanical properties when added to the cement matrix. PEG 400 has properties that can make concrete more effective in terms of water absorption, hydration heat and workability. The search for sustainability leads to research into new construction materials in order to preserve natural resources and reduce environmental impact. The concrete developed can be lower cost and more durable, without any loss of structural strength. Method/design/approach: The use of RC was investigated with partial substitutions of 2%, 5%, 10% and 20% in relation to the total mass of Portland cement for the manufacture of concrete and the addition of polyethylene glycol (PEG 400) as a self-curing agent. The void ratio, water absorption by capillarity and immersion, specific masses and pozzolanicity index of the waste were investigated. Mechanical and morphological characterization tests were also carried out on the concretes developed. Results and conclution: The compressive strength of concrete produced with 2% RC in relation to the total mass of cement and 1.5% PEG 400 increased by 18.3% compared to conventional concrete. An increase in the amount of residue caused a reduction in concrete strength. The sample with 1.5% PEG 400 obtained better workability in the fresh state, which may be due to the polymer acting as a self-healing agent. The images obtained by scanning electron microscopy showed that the samples containing 2% added RC had lower porosity. The study showed that the waste can be used satisfactorily in civil construction and the implementation of this new process can reduce global warming and the scarcity of mineral resources, taking sustainability into account. Research implications: This work contributes to a sustainable circular economy with a new process for using petroleum catalyst waste, with pozzolanic characteristics, in cementitious materials. Originality/value: The results will be promising for the use of petroleum catalyst waste and polyethylene glycol in the production of environmentally sustainable concrete.
28 July 2023 in Environmental Science and Pollution Research
RESUMO O trabalho objetivou avaliar a remoção concomitante de duas cianotoxinas - microcistina-LR e saxitoxina-STX - por meio da adsorção em carvão ativado granular. Em primeira etapa, três carvões de granulometrias distintas, dois de coco de dendê e um mineral, foram avaliados na adsorção de microcistina-LR em água destilada e tratada com concentrações de 3,9 a 9,4 ug.L-1. O carvão de coco de dendê de menor granulometria apresentou desempenho mais uniforme, tanto no que tange à remoção (%) de microcistina-LR, quanto ao volume de efluente produzido consoante com as recomendações do padrão de potabilidade brasileiro. Em segunda etapa, apenas para o carvão selecionado na etapa precedente, concentrações de microcistina-LR e saxitoxina-STX aproximadamente 50% superiores dos limites do mesmo padrão de potabilidade foram dispersas em água destilada. Tais ensaios de adsorção evidenciaram que apenas a adsorção de saxitonina não foi influenciada pela simultaneidade das duas cianotoxinas.
1 December 2019 in Engenharia Sanitaria e Ambiental
RESUMO O presente trabalho visou avaliar, por meio de regressão linear múltipla (RLM), os indicadores que melhor exprimem a realidade dos sistemas de abastecimento de água de municípios de pequeno porte, com base nos desempenhos financeiro, operacional e de qualidade da água como variáveis de resposta. A organização e a seleção dos dados fiaram-se no Sistema Nacional de Informações sobre Saneamento de 2014, tendo sido selecionados os referentes a 182 municípios de Minas Gerais com população inferior a 10 mil habitantes e 56 indicadores como variáveis explicativas. Por meio da RLM, verificou-se que o comprometimento das receitas com a despesa (margem da despesa de exploração) e a razão entre a arrecadação e as despesas (índice de suficiência de caixa) são as variáveis mais relevantes para descrever o desempenho financeiro. Para descrição do desempenho operacional, os índices de perdas por ligação e de faturamento de água foram os mais recorrentes. Por fim, no que tange ao desempenho de qualidade da água, os modelos apresentaram baixos coeficientes de determinação e a não aderência dos resíduos à distribuição normal.