Marta Lacort

Mrs. Marta Lacort

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 October 2025 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
María Romero-SanzMaría Romero-Sanz
María Romero-Sanz
MRMaría Teresa Pérez Roche
María Teresa Pérez Roche
MVMarina Vilella
Marina Vilella
AEAdrián Alejandre Escriche
Adrián Alejandre Escriche
EEEduardo Esteban-Ibañez
Eduardo Esteban-Ibañez
VPVictoria Pueyo
Victoria Pueyo
Background/Objectives: This study aims to investigate the development of oculomotor behavior in children born preterm using a DIVE device (Device for an Integral Visual Examination) equipped with eye-tracking technology. Visual and visuo-cognitive measures obtained through eye-tracking technology provide quantitative and sensitive indicators of early neural development, as visual function is one of the earliest cerebral processes to develop postnatally. Design: This is a cross-sectional study. Participants: The study included 428 children aged 0.5 to 14 years. Of these, 214 were born preterm (78 late preterm, born at 32–36 weeks’ gestation, and 136 early preterm, born at less than 32 weeks’ gestation) and 214 were full-term controls, matched by age and gender. Methods: All participants underwent a comprehensive ophthalmological assessment. Oculomotor behavior was analyzed using a DIVE device, focusing on fixation duration, saccadic performance and fixation stability. Fixation stability was quantified by the bivariate contour ellipse area for short tasks (BCEA), which measures (in deg2) the area of the ellipse enclosing a specified percentage of fixation positions—smaller BCEA values indicate greater fixation stability. We performed a cluster analysis on these oculomotor metrics to identify distinct oculomotor control patterns. Results: Preterm children exhibited significantly poorer fixation stability than controls (mean BCEA 0.21 vs. 0.09 logdeg2, p = 0.004), alongside shorter fixation durations and longer saccadic reaction times. Early preterm children showed more unstable fixations compared to late-preterm and control groups (0.26 vs. 0.12 and 0.09 logdeg2, respectively, p = 0.001). Cluster analysis revealed three distinct OMC (oculomotor control) patterns: “good,” “impulsive,” and “poor.” Children classified in the “good OMC” cluster demonstrated stable fixations and appropriate saccadic reaction times. In contrast, those in the “impulsive OMC” and “poor OMC” clusters exhibited more unstable fixations and abnormal saccadic times, with the “poor” cluster being significantly associated with extreme prematurity, lower birth weights, and a higher incidence of intraventricular hemorrhage (IVH). Conclusions: Preterm birth is associated with measurable oculomotor deficits, most pronounced in early preterm infants, affecting their fixation and saccadic abilities. The findings emphasize the need for targeted interventions to support the development of preterm children, particularly those with “poor” oculomotor control behavior.

23 September 2024 in Vision
Verified
Journal Article
Open access
PDF file
BMBlanca Montori
Blanca Montori
TRTeresa Pérez Roche
Teresa Pérez Roche
MVMarina Vilella
Marina Vilella
ELEstela López
Estela López
AEAdrián Alejandre Escriche
Adrián Alejandre Escriche
VPVictoria Pueyo
Victoria Pueyo
Purpose: To compare different visual acuity (VA) tests (printed and digital, symbols and letters) and to validate a new device for VA testing called DIVE (Devices for an Integral Visual Examination). Methods: VA was tested in a wide spectrum of adult people with printed tests (ETDRS and LEA Symbols) and with two implemented tests in DIVE (HOTV and DIVE Symbols). We measured agreement between the different VA tests using the intraclass correlation coefficient and Bland–Altman method. In addition, we measured the repeatability of all tests. Results: Right eyes from 51 adult participants were included in the study. Correlation between tests was high (ICC from 0.95 to 0.97). Bland–Altman analysis showed good agreement among the different tests, with differences within reasonable clinical limits. However, slightly better VA values were obtained with DIVE HOTV and ETDRS, followed by LEA and DIVE Symbols. ETDRS had the best repeatability. Conclusion: The four evaluated VA tests provide comparable outcomes. In an adult sample, letter optotypes obtained better VA values than symbol optotypes. DIVE VA tests are reliable and well-correlated with printed VA tests.

29 December 2025 in Journal of Eye Movement Research
Verified
Journal Article
Open access
PDF file
MLMarta Lacort
Marta Lacort
AAAdrián Alejandre
Adrián Alejandre
SGSara Guillén-Garde
Sara Guillén-Garde
MVMarina Vilella
Marina Vilella
XPXian Pan
Xian Pan
EEEduardo Esteban-Ibañez
Eduardo Esteban-Ibañez
Eye tracking (ET) technology is increasingly used in both research and clinical practice, but its accuracy may be compromised by the presence of ophthalmic lenses. This study systematically evaluated the influence of different optical prescriptions and lens treatments on ET performance using DIVE (Device for an Integral Visual Examination). Fourteen healthy participants underwent oculomotor control tests under thirteen optical conditions: six with varying dioptric powers and six with optical filters, compared against a no-lens control. Key parameters analysed included angle error, fixation stability (bivariate contour ellipse area, BCEA), saccadic accuracy, number of data gaps, and proportion of valid frames. High-powered spherical lenses (+6.00 D and −6.00 D) significantly increased gaze angle error, and the negative lens also increased data gaps, while cylindrical lenses had a moderate effect. Among filters, the Natural IR coating caused the greatest deterioration in ET performance, reducing valid samples and increasing the number of gaps with data loss, likely due to interference with the infrared-based detection system. The lens with basic anti-reflective treatment (SV Org 1.5 AR) also showed some deterioration in interaction with the ET. Other filters showed minimal or no significant impact. These findings demonstrate that both high-powered prescriptions and certain lens treatments can compromise ET data quality, highlighting the importance of accounting for optical conditions in experimental design and clinical applications.