There remains a debate whether the ventricular volume within prolapsing mitral valve (MV) leaflets should be included in the left ventricular (LV) end-systolic volume, and therefore factored in LV stroke volume (SV), in cardiac magnetic resonance (CMR) assessments. This study aims to compare LV volumes during end-systolic phases, with and without the inclusion of the volume of blood on the left atrial aspect of the atrioventricular groove but still within the MV prolapsing leaflets, against the reference LV SV by four-dimensional flow (4DF). A total of 15 patients with MV prolapse (MVP) were retrospectively enrolled in this study. We compared LV SV with (LV SVMVP) and without (LV SVstandard) MVP left ventricular doming volume, using 4D flow (LV SV4DF) as the reference value. Significant differences were observed when comparing LV SVstandard and LV SVMVP (p < 0.001), and between LV SVstandard and LV SV4DF (p = 0.02). The Intraclass Correlation Coefficient (ICC) test demonstrated good repeatability between LV SVMVP and LV SV4DF (ICC = 0.86, p < 0.001) but only moderate repeatability between LV SVstandard and LV SV4DF (ICC = 0.75, p < 0.01). Calculating LV SV by including the MVP left ventricular doming volume has a higher consistency with LV SV derived from the 4DF assessment. In conclusion, LV SV short-axis cine assessment incorporating MVP dooming volume can significantly improve the precision of LV SV assessment compared to the reference 4DF method. Hence, in cases with bi-leaflet MVP, we recommend factoring in MVP dooming into the left ventricular end-systolic volume to improve the accuracy and precision of quantifying mitral regurgitation.
Background: Aortic conduit and reservoir functions can be directly measured by four-dimensional flow (4D flow) cardiovascular magnetic resonance (CMR). Methods: Twenty healthy controls (10 young and 10 age-gender-matched old controls) and 20 patients with heart failure with preserved ejection fraction (HFpEF) were recruited. All had 4D flow CMR. Flow was quantified at the ascending and descending aorta levels. In addition, at the ascending aorta level, we quantified systolic flow displacement (FDs) and systolic flow reversal ratio (sFRR). The aortic conduit function was defined as the relative drop in systolic flow from the ascending to the descending aorta (∆Fs). Aortic reservoir function was defined as descending aortic diastolic stroke volume (DAo SVd). Results: Both ∆Fs (R=0.51, p=0.001) and DAo SVd (R=−0.68, p=0.001) were significantly associated with ageing. Native T1 (R=0.51, p=0.001) and extracellular volume (R=0.51, p=0.001) showed maximum association with ∆Fs. ∆Fs significantly increased in HFpEF versus age-gender-matched controls (41±8% vs 52±12%, p=0.02). In multiple regression, only ∆Fs and DAo SVd were independent predictors of the estimated glomerular filtration rate (model R=0.77, p=0.0001). FDs was significantly associated with ∆Fs (R=0.4, p=0.01) and DAo SVd (R=−0.48, p=0.002), whereas sFRR was mainly associated with DAo SVd (R=−0.46, p=0.003). Conclusion: Both aortic conduit and reservoir function decline with age and this decline in aortic function is also independently associated with renal functional decline. Ascending aortic turbulent flow signatures are associated with loss of aortic conduit and reservoir functions. Finally, in HFpEF, aortic conduit and reservoir function demonstrate progressive decline. Trials registration number: NCT05114785.
(1) Background and Objectives: Flow assessment using cardiovascular magnetic resonance (CMR) provides important implications in determining physiologic parameters and clinically important markers. However, post-processing of CMR images remains labor- and time-intensive. This study aims to assess the validity and repeatability of fully automated segmentation of phase contrast velocity-encoded aortic root plane. (2) Materials and Methods: Aortic root images from 125 patients are segmented by artificial intelligence (AI), developed using convolutional neural networks and trained with a multicentre cohort of 160 subjects. Derived simple flow indices (forward and backward flow, systolic flow and velocity) and complex indices (aortic maximum area, systolic flow reversal ratio, flow displacement, and its angle change) were compared with those derived from manual contours. (3) Results: AI-derived simple flow indices yielded excellent repeatability compared to human segmentation (p < 0.001), with an insignificant level of bias. Complex flow indices feature good to excellent repeatability (p < 0.001), with insignificant levels of bias except flow displacement angle change and systolic retrograde flow yielding significant levels of bias (p < 0.001 and p < 0.05, respectively). (4) Conclusions: Automated flow quantification using aortic root images is comparable to human segmentation and has good to excellent repeatability. However, flow helicity and systolic retrograde flow are associated with a significant level of bias. Overall, all parameters show clinical repeatability.