YOUNES ABOUELMAHJOUB

Dr. YOUNES ABOUELMAHJOUB

LabSIPE, Chouaib Doukkali University, El Jadida, Morocco
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 March 2021 in International Journal of Photoenergy
Verified
Journal Article
Open access
PDF file
Abdelkhalek ChellakhiAbdelkhalek Chellakhi
Abdelkhalek Chellakhi
SBSaid EL BEID
Said EL BEID
YOUNES ABOUELMAHJOUBYOUNES ABOUELMAHJOUB
YOUNES ABOUELMAHJOUB
This paper is aimed at harvesting the photovoltaic systems extracting power under difficult irradiance and load conditions, by proposing a novel maximum power point tracking (MPPT). This proposed MPPT tactic has been examined under various climatic and load conditions using two powerful and accurate simulation environments for PV systems, MATLAB/Simulink and Proteus. The first implementation using the MATLAB/Simulink software was carried out to examine the performance of the novel MPPT tactic under sudden insolation and load change, where the second implementation using the Proteus software was carried out in order to prove that the novel MPPT tactic can be easily implemented using low-cost components, Arduino board, and LCD display. The simulation results prove that the novel MPPT tactic has a high convergence speed to locate the MPP, especially at fast solar irradiation and load variation with zero oscillation under steady-state operation, which takes less than 9.6 milliseconds (ms) under the MATLAB/Simulink software and 0.24 microseconds (μs) under Proteus environment. That means it is about six times faster than PO and five times faster than INC MPPT methods, and its tracking efficiency is between 99.40 and 99.86. Furthermore, the novel MPPT tactic shows the best tracking accuracy and better ability to mitigate power losses under overall simulation scenarios compared with other traditional MPPT methods.

14 April 2022 in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
Verified
Journal Article
Closed access
Abdelkhalek ChellakhiAbdelkhalek Chellakhi
Abdelkhalek Chellakhi
SBSaid EL BEID
Said EL BEID
YOUNES ABOUELMAHJOUBYOUNES ABOUELMAHJOUB
YOUNES ABOUELMAHJOUB
This paper offers an innovative maximum power point tracking (MPPT) approach for photovoltaic system under temperature varying. Basically, the innovative approach is introduced to improve tracking performance under difficult scenarios of temperature change. By far, it can be used to avoid the main shortcomings of the conventional MPPT strategies, e.g., ripple around the MPP at steady-state regime, sluggishness velocity converging, and loss of tracking direction under fast change of temperature. Also, it can be used to improve the tracking performance under low irradiance level and rapid load change. With respect to its direct control strategy based on the photovoltaic current control, it provides a quick tracking of the real MPP without steady-state fluctuations. To show the advantages and accuracy of the innovative MPPT approach, a comparison with other traditional strategies, e.g., P&O and INC techniques is investigated using simulation in MATLAB/Simulink® software under different scenarios of temperature, load, and insolation levels. In the light of the results collected, the innovative MPPT approach minimized the convergence time by five times, reduced the steady-state fluctuations to zero and improved the average tracking efficiency by 8.51% and 9.04% compared to the P&O and INC MPPT schemes, respectively.

10 June 2021 in International Journal of Photoenergy
Verified
Journal Article
Open access
PDF file
Abdelkhalek ChellakhiAbdelkhalek Chellakhi
Abdelkhalek Chellakhi
SBSaid EL BEID
Said EL BEID
YOUNES ABOUELMAHJOUBYOUNES ABOUELMAHJOUB
YOUNES ABOUELMAHJOUB
This paper develops and discusses an improved MPPT approach for temperature variation with fast-tracking speed and reduced steady-state oscillation. This MPPT approach can be added to numerous existing MPPT algorithms in order to enhance their tracking accuracy and response time and to reduce the power loss. The improved MPPT method is fast and accurate to follow the maximum power point under critical temperature conditions without increasing the implementation complexity. The simulation results under different scenarios of temperature and insolation were presented to validate the advantages of the proposed method in terms of tracking efficiency and reduction of power loss at dynamic and steady-state conditions. The simulation results obtained when the proposed MPPT technique was added to different MPPT techniques, namely, perturb and observe (P&O), incremental conductance (INC), and modified MPP-Locus method, show significant enhancements of the MPP tracking performances, where the average efficiency of the conventional P&O, INC, and modified MPP-Locus MPPT methods under all scenarios is presented, respectively, as 98.85%, 98.80%, and 98.81%, whereas the average efficiency of the improved P&O, INC, and modified MPP-Locus MPPT methods is 99.18%, 99.06%, and 99.12%, respectively. Furthermore, the convergence time enhancement of the improved approaches over the conventional P&O, INC, and modified MPP-Locus methods is 2.06, 5.25, and 2.57 milliseconds, respectively; besides, the steady-state power oscillations of the conventional P&O, INC, and modified MPP-Locus MPPT methods are 2, 1, and 0.6 watts, but it is neglected in the case of using the improved approaches. In this study, the MATLAB/Simulink software package was selected for the implementation of the whole PV system.

10 April 2025 in Journal of the Franklin Institute
Verified
Journal Article
Closed access
YMYoussef Mchaouar
Youssef Mchaouar
HAHassan Abouobaida
Hassan Abouobaida
YOUNES ABOUELMAHJOUBYOUNES ABOUELMAHJOUB
YOUNES ABOUELMAHJOUB
AAAbdelmajid Abouloifa
Abdelmajid Abouloifa
ILIbtissam Lachkar
Ibtissam Lachkar
JGJosep M. Guerrero
Josep M. Guerrero

24 September 2022 in International Journal of Photoenergy
Verified
Journal Article
Open access
PDF file
Abdelkhalek ChellakhiAbdelkhalek Chellakhi
Abdelkhalek Chellakhi
SBSaid EL BEID
Said EL BEID
YOUNES ABOUELMAHJOUBYOUNES ABOUELMAHJOUB
YOUNES ABOUELMAHJOUB
The purpose of this paper is to enhance the performance and tracking efficiency of solar photovoltaic systems. This aim can be achieved by operating the photovoltaic array at its optimum power and reducing the output ripple problem of DC-DC converters that affect and stress sensible electronic loads. In view of that, an advanced maximum power point (MPP) tracking (MPPT) scheme, which can guarantee zero oscillation tracking of the accessible MPP and less ripple magnitude on the output side of the DC-DC boost converter, is used. Various simulations are carried out under three conditions of solar irradiance variation, namely, standard test conditions (STC), rapid, and Sin scenarios, using the MATLAB/Simulink® environment, to assess and benchmark the robustness of the tracking of the new MPPT scheme over the celebrated Increment of Conductance (INC) MPPT scheme. Based on the simulation results, the proposed scheme can significantly improve tracking accuracy and reduce the magnitude of ripples on both sides of the boost converter compared to the INC scheme. Certainly, the proposed scheme can provide a shorter time response (0.011 seconds) to locate and track the expected MPP, which is 2.55 times less than that of the INC scheme; a zero power magnitude oscillation instead of 15.9 watts of the INC scheme; and six-time minimization of the magnitude of output voltage ripples compared to the INC scheme. Furthermore, the suggested MPPT scheme has the better tracking efficiency in all scenarios; 99.86%, 99.60%, and 99.62% in the STC, rapid, and Sin scenarios, respectively, with an average value of 99.69% compared to the INC MPPT scheme, which has 94.23%, 95.28%, and 97.87% in the STC, rapid, and Sin scenarios, respectively, with a moderate average tracking efficiency of 95.79%. Finally, the accuracy and tracking performance of the proposed MPPT scheme are verified by real-time examination using the RT-LAB simulator. According to the results obtained, the proposed scheme provides the highest tracking efficiency of 99.80% and 97.77% under the STC and sudden insolation change scenarios, respectively, compared to the INC scheme, which shows, respectively, 97.8% and 96.5% under both scenarios.

21 July 2021 in International Journal of Photoenergy
Verified
Journal Article
Open access
PDF file
Hassan AbouobaidaHassan Abouobaida
Hassan Abouobaida
YOUNES ABOUELMAHJOUBYOUNES ABOUELMAHJOUB
YOUNES ABOUELMAHJOUB
This paper discusses open-circuit fault (OCF) diagnosis and fault-tolerant control strategy (FTCS) of a nonisolated DC-DC converter. The photovoltaic power conversion structure (PPCS) consists of a photovoltaic generator and an interleaved Boost converter (IBC). The maximum power point tracking (MPPT) control of the IBC ensures operation at maximum power. The design of the nonlinear Backstepping control is detailed based on the equivalent average model of IBC, and the stability is studied using Lyapunovs theorem. The proposed OCF fault detection is based on sampling the voltage across the inductor at a much higher frequency than the switching frequency. In an OCF situation occurrence and a high control signal state, the detection of three negative samples is a condition for signaling the presence of an OCF fault; the photovoltaic system continues its normal operation. The simulation results show the validity of the proposed FTCS. The proposed diagnosis and control strategy improves the performance of the IBC in terms of cost, reliability, and service continuity.