Liwen Feng

Mr. Liwen Feng

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 November 2024 in Physical Review Research
Verified
Journal Article
Open access
HJH. Jia
H. Jia
TLT. Li
T. Li
TWT. Wang
T. Wang
YZY. Zhao
Y. Zhao
XZXiang Zhang
Xiang Zhang
SHSenlin Huang
Senlin Huang
High-brightness megahertz-rate electron beams are highly desired for cutting-edge applications in many areas of science. Photocathode electron guns capable of generating such beams with low dark current remain to be a challenging field. In this paper, we report breakthroughs with a hybrid gun combining a direct-current gap and a superconducting radio-frequency (SRF) cavity. The gun, employing K 2 CsSb photocathodes driven by a green laser, delivers a few MeV electron beam at 1 and 81.25 MHz rates with an average current up to 3 mA and a dark current several orders lower than current normal conducting continuous-wave guns. Emittance compensation and multipole field corrections have been applied to achieve a high-quality beam. The achievement will inspire the development of high-brightness SRF guns and promote megahertz-rate beam applications including coherent linac light sources and ultrafast electron diffraction/microscopy. Published by the American Physical Society 2024

9 August 2024 in Photonics
Verified
Journal Article
Open access
PDF file
XZXiang Zhang
Xiang Zhang
HXHang Xu
Hang Xu
LFLiwen Feng
Liwen Feng
ZLZhongqi Liu
Zhongqi Liu
TWTianyi Wang
Tianyi Wang
SHSenlin Huang
Senlin Huang
Temperature control is important in second harmonic generation (SHG) based on non-critical phase matching, which is widely used in the accelerator field to generate drive lasers. To further improve the stability of the drive laser for the DC-SRF photocathode electron gun at Peking University, a high-precision temperature control oven for lithium borate (LBO) crystals was developed. The oven’s structure was designed to minimize heat exchange with the external environment. The temperature control circuit uses a thermoelectric cooler to ensure the temperature stability of the sampling circuit. The program utilizes a cascaded proportional-integral-derivative and an anti-saturation integral algorithm to achieve high-precision temperature control. Experiments showed that fluctuation at the working temperature of the LBO crystal in this oven was within ±0.009 °C, corresponding to a root mean square (RMS) jitter of 0.003 °C, and the long-term power fluctuation of the 13.7 W green laser generated with SHG was less than 1%.

1 March 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
DODongming Ouyang
Dongming Ouyang
YZYonglong Zhao
Yonglong Zhao
HXHuamu Xie
Huamu Xie
XZXinkai Zhang
Xinkai Zhang
SZSheng Zhao
Sheng Zhao
SHSenlin Huang
Senlin Huang

21 July 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MRManqian Ren
Manqian Ren
LLLin Lin
Lin Lin
JHJiankui Hao
Jiankui Hao
GWGai Wang
Gai Wang
ZWZiyu Wang
Ziyu Wang
SHSenlin Huang
Senlin Huang
A liquid helium-free cryostat for radio frequency (RF) test of the superconducting cavity is designed and constructed. Gifford-Mcmahon (G-M) cryocoolers are used to provide cooling capacity, and the heat leakage at 4 K is less than 0.02 W. Vertical and horizontal tests of two Nb3Sn cavities are carried out in the cryostat with different surface treatments outside the cavities. Both of the cavities achieve stable continuous wave (CW) operation. A novel treatment, which cold-sprayed a 3.5 mm thick Cu layer onto the outside of the cavity, enables the maintenance of an average temperature of 5.5 K in the cavity at a RF loss of 10 W, implying that the thermal stability and uniformity of the cavity has been significantly improved. Through the synergistic control of four metal film resistors, a cooling rate of 0.06 K/min near 18 K is realized, and the cavity temperature gradient is reduced to 0.17 K/m, which effectively improves the RF performance of the cavity. The maximum Eacc of the cavity reaches 3.42 MV/m, and the Q0 is 1.1 × 109. An electromagnetic–thermal coupling simulation model for the superconducting cavity is established and is in good agreement with the experimental results. The simulation results show that the cavity with a Cu-spraying treatment and the thermal links of 5N Al can satisfy the Eacc of 10 MV/m under conduction cooling.

1 September 2021 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
YLYunqi Liu
Yunqi Liu
DZDehao Zhuang
Dehao Zhuang
FWFang Wang
Fang Wang
LLLin Lin
Lin Lin
LFLiwen Feng
Liwen Feng
KLKexin Liu
Kexin Liu

1 March 2025 in Journal of Instrumentation
Verified
Journal Article
Closed access
HZHao Zeng
Hao Zeng
NGNan Gan
Nan Gan
HXHang Xu
Hang Xu
LFLiwen Feng
Liwen Feng
XHXiang He
Xiang He
JLJingyi Li
Jingyi Li
A laser-microwave synchronization system using an all-fiber optical-microwave phase detector (AFOM-PD) has been developed and experimentally validated at the Institute of High Energy Physics (IHEP). A Yb-doped fiber amplifier (YDFA) was employed to suppress the relative intensity noise (RIN) of the reference laser. And the root-mean-square (RMS) integrated RIN was reduced from 7.78 × 10-4 before suppression to 6 × 10-5 after suppression in the interval of 1 Hz to 1 MHz. The performance of this system has been demonstrated using a mode-locked fiber laser with a repetition rate of 29.1 MHz, in conjunction with L-band and S-band microwave signals. Residual phase noise levels of -118 dBc/Hz and -116 dBc/Hz at the 1-Hz offset frequency have been achieved for the L-band and S-band microwave signals, respectively. The integrated RMS timing jitters measured within the frequency range of 1 Hz to 1 MHz during the same experiments are 18.6 fs for the L-band signals and 6.0 fs for the S-band signals. Tests conducted over a 6-hour period have shown that this system can achieve a long-term RMS timing drift of less than 16 fs. This system has potential applications in the plasma wakefield accelerator currently being developed at IHEP.