Rebecca S. Just

Dr. Rebecca S. Just


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2015 in Forensic Science International: Genetics
Verified
Journal Article
Open access
RJRebecca S. Just
Rebecca S. Just
MSMelissa K. Scheible
Melissa K. Scheible
SFSpence A. Fast
Spence A. Fast
KSKimberly Sturk-Andreaggi
Kimberly Sturk-Andreaggi
ARAlexander W. Röck
Alexander W. Röck
JIJodi A. Irwin
Jodi A. Irwin
Though investigations into the use of massively parallel sequencing technologies for the generation of complete mitochondrial genome (mtGenome) profiles from difficult forensic specimens are well underway in multiple laboratories, the high quality population reference data necessary to support full mtGenome typing in the forensic context are lacking. To address this deficiency, we have developed 588 complete mtGenome haplotypes, spanning three U.S. population groups (African American, Caucasian and Hispanic) from anonymized, randomly-sampled specimens. Data production utilized an 8-amplicon, 135 sequencing reaction Sanger-based protocol, performed in semi-automated fashion on robotic instrumentation. Data review followed an intensive multi-step strategy that included a minimum of three independent reviews of the raw data at two laboratories; repeat screenings of all insertions, deletions, heteroplasmies, transversions and any additional private mutations; and a check for phylogenetic feasibility. For all three populations, nearly complete resolution of the haplotypes was achieved with full mtGenome sequences: 90.3-98.8% of haplotypes were unique per population, an improvement of 7.7-29.2% over control region sequencing alone, and zero haplotypes overlapped between populations. Inferred maternal biogeographic ancestry frequencies for each population and heteroplasmy rates in the control region were generally consistent with published datasets. In the coding region, nearly 90% of individuals exhibited length heteroplasmy in the 12418-12425 adenine homopolymer; and despite a relatively high rate of point heteroplasmy (23.8% of individuals across the entire molecule), coding region point heteroplasmies shared by more than one individual were notably absent, and transversion-type heteroplasmies were extremely rare. The ratio of nonsynonymous to synonymous changes among point heteroplasmies in the protein-coding genes (1:1.3) and average pathogenicity scores in comparison to data reported for complete substitutions in previous studies seem to provide some additional support for the role of purifying selection in the evolution of the human mtGenome. Overall, these thoroughly vetted full mtGenome population reference data can serve as a standard against which the quality and features of future mtGenome datasets (especially those developed via massively parallel sequencing) may be evaluated, and will provide a solid foundation for the generation of complete mtGenome haplotype frequency estimates for forensic applications.

1 January 2020 in Forensic Science International: Genetics
Verified
Journal Article
Open access
MBMichael Brandhagen
Michael Brandhagen
RJRebecca S. Just
Rebecca S. Just
JIJodi Irwin
Jodi Irwin
As a first step towards integrating next generation sequencing (NGS) technology into the FBI Laboratory's operational casework, the PowerSeq™ CRM Nested System, an NGS-based mitochondrial DNA (mtDNA) control region assay, was developmentally and internally validated. The validation studies were conducted in accordance with the Scientific Working Group on DNA Analysis Methods (SWGDAM) Validation Guidelines for Forensic DNA Analysis Methods, and the FBI's Quality Assurance Standards (QAS) for Forensic DNA Testing Laboratories. The assay was shown to be highly reproducible, with variant frequencies across intra and inter-run replicates of the same sample differing, on average, by just 0.3% for substitutions and point heteroplasmies and 1.5% for insertions and deletions. The assay was also shown to be extremely sensitive, yielding complete control region sequence data from as few as 2000 copies of mtDNA. This is a more than 20-fold increase in sensitivity when compared to the FBI Laboratory's current Sanger sequencing-based protocols and, based on mtDNA quantitation values of samples routinely encountered in mtDNA casework, suggests that the percentage of questioned samples from which full control region data can be recovered will increase from our current 20% to approximately 90% success with NGS technology. In addition, the assay requires on average only 30% of the extract volume typically required to develop control region profiles from degraded samples via Sanger sequencing. Overall, these studies establish the reliability of the PowerSeq™ CRM Nested System for accurate mtDNA control region typing and can serve as a model for laboratories seeking to validate NGS protocols for forensic mtDNA analysis.

16 December 2013 in BMC Genomics
Verified
Journal Article
Open access
PDF file
ELElizabeth A Lyons
Elizabeth A Lyons
MSMelissa K Scheible
Melissa K Scheible
KSKimberly Sturk-Andreaggi
Kimberly Sturk-Andreaggi
JIJodi A Irwin
Jodi A Irwin
RJRebecca S. Just
Rebecca S. Just
A population reference database of complete human mitochondrial genome (mtGenome) sequences is needed to enable the use of mitochondrial DNA (mtDNA) coding region data in forensic casework applications. However, the development of entire mtGenome haplotypes to forensic data quality standards is difficult and laborious. A Sanger-based amplification and sequencing strategy that is designed for automated processing, yet routinely produces high quality sequences, is needed to facilitate high-volume production of these mtGenome data sets.

23 July 2007 in Journal of Forensic Sciences
Verified
Journal Article
Closed access
PDF file
JIJodi A. Irwin
Jodi A. Irwin
SESuni M. Edson
Suni M. Edson
OLOdile Loreille
Odile Loreille
RJRebecca S. Just
Rebecca S. Just
SBSuzanne M. Barritt
Suzanne M. Barritt
MLMark D. Leney
Mark D. Leney

1 May 2018 in Forensic Science International: Genetics
Verified
Journal Article
Open access
RJRebecca S. Just
Rebecca S. Just
JIJodi Irwin
Jodi Irwin
Some of the expected advantages of next generation sequencing (NGS) for short tandem repeat (STR) typing include enhanced mixture detection and genotype resolution via sequence variation among non-homologous alleles of the same length. However, at the same time that NGS methods for forensic DNA typing have advanced in recent years, many caseworking laboratories have implemented or are transitioning to probabilistic genotyping to assist the interpretation of complex autosomal STR typing results. Current probabilistic software programs are designed for length-based data, and were not intended to accommodate sequence strings as the product input. Yet to leverage the benefits of NGS for enhanced genotyping and mixture deconvolution, the sequence variation among same-length products must be utilized in some form. Here, we propose use of the longest uninterrupted stretch (LUS) in allele designations as a simple method to represent sequence variation within the STR repeat regions and facilitate - in the nearterm - probabilistic interpretation of NGS-based typing results. An examination of published population data indicated that a reference LUS region is straightforward to define for most autosomal STR loci, and that using repeat unit plus LUS length as the allele designator can represent greater than 80% of the alleles detected by sequencing. A proof of concept study performed using a freely available probabilistic software demonstrated that the LUS length can be used in allele designations when a program does not require alleles to be integers, and that utilizing sequence information improves interpretation of both single-source and mixed contributor STR typing results as compared to using repeat unit information alone. The LUS concept for allele designation maintains the repeat-based allele nomenclature that will permit backward compatibility to extant STR databases, and the LUS lengths themselves will be concordant regardless of the NGS assay or analysis tools employed. Further, these biologically based, easy-to-derive designations uphold clear relationships between parent alleles and their stutter products, enabling analysis in fully continuous probabilistic programs that model stutter while avoiding the algorithmic complexities that come with string based searches. Though using repeat unit plus LUS length as the allele designator does not capture variation that occurs outside of the core repeat regions, this straightforward approach would permit the large majority of known STR sequence variation to be used for mixture deconvolution and, in turn, result in more informative mixture statistics in the near term. Ultimately, the method could bridge the gap from current length-based probabilistic systems to facilitate broader adoption of NGS by forensic DNA testing laboratories.

15 October 2014 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
RJRebecca S. Just
Rebecca S. Just
JIJodi A. Irwin
Jodi A. Irwin
Walther ParsonWalther Parson
Walther Parson