Van Dau

Dr. Van Dau

Griffith School of Engineering and Built Environment, Griffith University, Nathan, QLD 4111, Australia
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 April 2018 in Sensors
Verified
Journal Article
Open access
PDF file
RMRehana Munas
Rehana Munas
Gehan MelroyGehan Melroy
Gehan Melroy
CGChamitha Galhenage
Chamitha Galhenage
HCHiniduma Liyanage Chathuranga
Hiniduma Liyanage Chathuranga
RARanjith Amarasinghe
Ranjith Amarasinghe
Dzung DaoDzung Dao
Dzung Dao
A piezoelectrically actuated valveless micropump has been designed and developed. The principle components of this system are piezoelectrically actuated (PZT) metal diaphragms and a complete fluid flow system. The design of this pump mainly focuses on a cross junction, which is generated by a nozzle jet attached to a pump chamber and the intersection of two inlet channels and an outlet channel respectively. During each PZT diaphragm vibration cycle, the junction connecting the inlet and outlet channels with the nozzle jet permits consistencies in fluidic momentum and resistances in order to facilitate complete fluidic path throughout the system, in the absence of any physical valves. The entire micropump structure is fabricated as a plate-by-plate element of polymethyl methacrylate (PMMA) sheets and sandwiched to get required fluidic network as well as the overall device. In order to identify the flow characteristics, and to validate the test results with numerical simulation data, FEM analysis using ANSYS was carried out and an eigenfrequency analysis was performed to the PZT diaphragm using COMSOL Multiphysics. In addition, the control system of the pump was designed and developed to change the applied frequency to the piezoelectric diaphragms. The experimental data revealed that the maximum flow rate is 31.15 mL/min at a frequency of 100 Hz. Our proposed design is not only for a specific application but also useful in a wide range of biomedical applications.

1 December 2015 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
Van DauVan Dau
Van Dau
TDT.X. Dinh
T.X. Dinh

19 May 2006 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
Van DauVan Dau
Van Dau
Dzung DaoDzung Dao
Dzung Dao
TSTatsuo Shiozawa
Tatsuo Shiozawa
HKHideo Kumagai
Hideo Kumagai
SSSusumu Sugiyama
Susumu Sugiyama

1 December 2016 in Experimental Thermal and Fluid Science
Verified
Journal Article
Closed access
Van DauVan Dau
Van Dau
TDThien Xuan Dinh
Thien Xuan Dinh
TBTung Bui
Tung Bui
CTCanh-Dung Tran
Canh-Dung Tran
HPHoa Thanh Phan
Hoa Thanh Phan
TTTibor Terebessy
Tibor Terebessy

19 October 2010 in Biomedical Microdevices
Verified
Journal Article
Closed access
PDF file
HFHideaki Fujita
Hideaki Fujita
Van DauVan Dau
Van Dau
KSKazunori Shimizu
Kazunori Shimizu
RHRanko Hatsuda
Ranko Hatsuda
SSSusumu Sugiyama
Susumu Sugiyama
ENEiji Nagamori
Eiji Nagamori

1 June 2016 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
Van DauVan Dau
Van Dau
TDThien Xuan Dinh
Thien Xuan Dinh
TTTibor Terebessy
Tibor Terebessy
TBTung Bui
Tung Bui