Saurabh Chandan

Dr. Saurabh Chandan

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 October 2019 in Surgical Endoscopy
Verified
Journal Article
Closed access
PDF file
BMBabu P. Mohan
Babu P. Mohan
SCSaurabh Chandan
Saurabh Chandan
LJLokesh K. Jha
Lokesh K. Jha
SKShahab R. Khan
Shahab R. Khan
RKRajesh Kotagiri
Rajesh Kotagiri
DADouglas G. Adler
Douglas G. Adler

15 March 2021 in Alimentary Pharmacology & Therapeutics
Verified
Journal Article
Closed access
DRDaryl Ramai
Daryl Ramai
JSJameel Singh
Jameel Singh
JLJanice Lester
Janice Lester
SKShahab R. Khan
Shahab R. Khan
SCSaurabh Chandan
Saurabh Chandan
Antonio FacciorussoAntonio Facciorusso
Antonio Facciorusso


1 September 2021 in Gastrointestinal Endoscopy
Verified
Journal Article
Closed access
SCSaurabh Chandan
Saurabh Chandan
SKShahab R. Khan
Shahab R. Khan
AKAnand Kumar
Anand Kumar
BMBabu P. Mohan
Babu P. Mohan
DRDaryl Ramai
Daryl Ramai
GKGursimran S. Kochhar
Gursimran S. Kochhar

9 May 2019 in Surgical Endoscopy
Verified
Journal Article
Closed access
PDF file
SCSaurabh Chandan
Saurabh Chandan
BMBabu Pappu Mohan
Babu Pappu Mohan
OCOjasvini Choudhry Chandan
Ojasvini Choudhry Chandan
LJLokesh Kumar Jha
Lokesh Kumar Jha
HMHarmeet Singh Mashiana
Harmeet Singh Mashiana
MKMouen A. Khashab
Mouen A. Khashab

1 September 2019 in Journal of Clinical Gastroenterology
Verified
Journal Article
Closed access
BMBabu P. Mohan
Babu P. Mohan
SCSaurabh Chandan
Saurabh Chandan
RGRajat Garg
Rajat Garg
SMShuaib Mohamed
Shuaib Mohamed
MSMohammed Shakhatreh
Mohammed Shakhatreh
DADouglas G. Adler
Douglas G. Adler
Background: Refractory benign gastrointestinal (GI) strictures are difficult to treat and placement of a stent is a commonly sought resort. Stents used for this purpose are fully covered self-expanding metal stent (FCSEMS), a biodegradable stent (BDS) and recently, a lumen-apposing metal stent (LAMS). There is no data comparing these stents to this end. Methods: We conducted a comprehensive search of multiple electronic databases and conference proceedings (from inception through October 2018) to identify studies that reported on the performance of FCSEMS, BDS, and LAMS in the treatment of refractory benign GI strictures. Our goals were to evaluate the pooled rate of technical success, clinical success, and adverse events with these stents and compare the outcomes between them. Results: A total of 31 studies were analyzed. In total, 14 (342 patients), 11 (226 patients), and 8 studies (192 patients) reported the use of FCSEMS, BDS, and LAMS, respectively. The pooled rate of technical success was 96.5% [95% confidence interval (CI): 93.5-98.1], 91.9% (95% CI: 85.6-95.6), and 97.6% (95% CI: 94.0-99.0) with FCSEMS, BDS, and LAMS respectively. No statistical significance to the difference was noted. The pooled rate of clinical success was 48.4% (95% CI: 37.1-59.8), 34.9% (95% CI: 23.6-48.1), and 78.8% (95% CI: 65.8-87.8) with FCSEMS, BDS, and LAMS, respectively. Statistical significance was noted in LAMS versus FCSEMS (P=0.001) and LAMS versus BDS (P=0.001). LAMS demonstrated statistically better outcomes in regards to stent migration and postprocedure pain when compared with FCSEMS and BDS. Conclusion: Our study demonstrates that LAMS gives better clinical outcomes in the treatment of refractory benign GI strictures when compared with FCSEMS and BDS. Variability in the site, as well as the length of stricture, indirect comparison, and heterogeneity, were the limitations of our study.