Bin Yan

Dr. Bin Yan

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 May 2019 in Metals
Verified
Journal Article
Open access
PDF file
BYBin Yan
Bin Yan
HLHongbo Li
Hongbo Li
Jie ZhangJie Zhang
Jie Zhang
NKNing Kong
Ning Kong
In this study, the effect of initial annealing microstructure of Ti–4Al–2V (TA17) alloy on forming characteristic was studied, so as to provide a basis for quality control of plastic forming of titanium alloy parts. The titanium alloy always undergoes annealing treatment before forming, due to different microstructures present different mechanical properties. The TA17 with different microstructures are obtained by means of various annealing treatment temperatures. The tensile behavior of TA17 is investigated at room temperature and 900 °C under constant strain rate of 0.01 s−1. The experimental results show that the mechanical properties of TA17 are sensitive to the initial microstructure before deformation. The microstructure of TA17 at 850 °C (2 h) is the equiaxed primary α-phase after the annealing process. It exhibits good plasticity at room temperature. This phenomenon is also confirmed from fracture morphology from the scanning electron microscope (SEM) analysis. At 900 °C, which is a high tensile temperature, the alloy with equiaxed primary α-phase performs outstanding plasticity compared with other microstructures. This work establishes a good understanding on the relationship between the mechanical properties and microstructures of TA17 at a wide temperature range.

12 February 2023 in Crystals
Verified
Journal Article
Open access
PDF file
GZGuocheng Zhang
Guocheng Zhang
YCYufang Chang
Yufang Chang
BYBin Yan
Bin Yan
Hexagonal boron nitride (h-BN) flakes have been widely used due to their excellent physical and chemical properties. Here, thermal-induced wrinkles of thin h-BN flakes deposited on silicon dioxide substrate were investigated through a combination of atomic force microscopy (AFM) and Raman spectroscopy. The experimental results indicated that the wrinkles did not occur at relatively low annealing temperatures and were detected at temperatures as high as 500 °C or even 600 °C. When repeatedly annealed at high temperatures, the number and positions of the wrinkles also changed. From the Raman spectra, the wrinkles were caused by the fact that the h-BN contraction rate was faster than that of the substrate at the cooling stage due to the interfacial sliding between the flake and the substrate and the h-BN flake of 7 nm thickness recovered to the original length at 150 °C. Further cooling introduced the compressive stress and then the wrinkles appeared. Moreover, it was found that if there was a crack in the h-BN flake, the wrinkle always appeared at the crack. Our findings appeal the mechanism of thermal-induced wrinkles of h-BN flakes and help us to research their applications as substrate materials in electronic devices in a high-temperature environment.

5 February 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
GZGuocheng Zhang
Guocheng Zhang
YCYufang Chang
Yufang Chang
NFNa Fan
Na Fan
BYBin Yan
Bin Yan
XLXianmeng Li
Xianmeng Li
ZYZhenyang Yu
Zhenyang Yu
In recent years, atomic force microscopes have been used for cell transfection because of their high-precision micro-indentation mode; however, the insertion efficiency of the tip of AFM into cells is extremely low. In this study, NIH3T3 mouse fibroblast cells cultured on a flexible dish with micro-groove patterns were subjected to various substrate strains at 5%, 10%, 15%, and 20%. It was found that the cell stiffness depends on the prestress of the cell membrane, and that the insertion rate of AFM tips into the cell membrane is proportional to the stiffness through the AFM indentation experiment. The finite element analysis proves that prestress increases the bending stiffness of the cytoskeleton, allowing it to better support the cell membrane, which realizes the stress concentration in the contact area between the AFM tip and the cell membrane. The results indicate that the prestress contributes to the mechanical properties of the cell and suggest that the insertion efficiency could be greatly improved with an increase of the prestress of the cell membrane.

27 May 2026 in Materials
Verified
Journal Article
Open access
PDF file
BYBin Yan
Bin Yan
GZGuocheng Zhang
Guocheng Zhang
XLXiaoli Liu
Xiaoli Liu
YYYidi Yang
Yidi Yang
This study aims to clarify the effects of initial microstructure and friction coefficient on the high-temperature formability of TA17 titanium alloy. Three typical microstructures were prepared via different annealing processes to provide theoretical and experimental support for hot forming process optimization. Existing studies on TA17 titanium alloy mainly focus on its room-temperature mechanical properties and corrosion resistance, while quantitative investigations on the influence of different initial microstructures on its high-temperature forming limit are still scarce. Moreover, the temperature evolution characteristics of the friction coefficient for TA17 alloy and its quantitative influence on deep-drawing forming limit remain unclear, and few studies have considered the effect of initial microstructure and friction coefficient on the high-temperature formability of titanium alloys. Combined with high-temperature tensile tests, high-temperature friction- wear tests and finite element (FE) simulation, the effects of microstructure characteristics and friction coefficient on the high-temperature formability of TA17 alloy were systematically investigated. The results show that the equiaxed microstructure obtained by annealing at 850 °C for 2 h exhibits the best high-temperature plasticity at 900 °C and strain rate of 0.01 s−1, while the plasticity of Widmanstätten and bimodal structures is significantly reduced. The high-temperature friction coefficient of TA17 alloy decreases sharply with increasing temperature, dropping from 0.56 at 650 °C to 0.19 at 800 °C, and can be stably controlled below 0.2 in the optimal forming temperature range of 800–900 °C. The friction coefficient has a remarkable influence on the deep-drawing forming limit: as the friction coefficient increases from 0.05 to 0.2, the limit principal strain and limit punch stroke decrease accordingly. This study reveals that fine equiaxed microstructure and low friction coefficient can enhance the high-temperature forming formability of TA17 titanium alloy. In actual industrial hot forming processes, it is recommended to use TA17 alloy with equiaxed microstructure and control the friction coefficient below 0.15 by using high-temperature lubricants, which can effectively improve the forming quality of complex aerospace structural components.

6 October 2026 in Measurement Science and Technology
Verified
Journal Article
Closed access
RGRuizhen Gao
Ruizhen Gao
YYYidi Yang
Yidi Yang
BLBaihua Li
Baihua Li
HPHaitao Pan
Haitao Pan
GLGuoguang Li
Guoguang Li
BYBin Yan
Bin Yan
3D Gaussian splatting (3DGS) shows strong performance in high-fidelity reconstruction and real-time novel view synthesis. However, its semantic understanding often relies on feature distillation or semantic field optimization during 3D reconstruction. This strategy not only hinders the reuse of existing 3D assets, but also limits rapid deployment on robotic platforms with constrained computational resources. For robotic perception, we propose TAGS, a topology-aware post-hoc Gaussian asset extraction framework without retraining. TAGS supports object-level open-vocabulary queries composed of object categories together with simple attributes such as color and state, and robustly extracts target Gaussian assets with high geometric fidelity from pre-built complex indoor 3DGS scenes. The framework introduces a topology-constrained 2D-to-3D lifting method to suppress background penetration and candidate contamination caused by depth occlusion. It also designs a view-quality-aware multi-view aggregation module, which uses view reliability weighting to alleviate Gaussian extraction bias from unreliable view observations. In addition, we construct an edge-gated Gaussian graph refinement module to recover the structural continuity and boundary completeness of target Gaussian assets without external 3D ground-truth supervision. Experiments show that TAGS achieves competitive extraction performance on both public benchmarks and real-world scenes, while demonstrating clear advantages in runtime efficiency and deployment friendliness. It provides high-quality 3D object representations for open-vocabulary robotic perception and subsequent object-level manipulation.

5 August 2026 in Materials Research Express
Verified
Journal Article
Open access
PDF file
BYBin Yan
Bin Yan
HLHairui Li
Hairui Li
GZGuocheng Zhang
Guocheng Zhang
XLXiaoli Liu
Xiaoli Liu
JFJuzheng Feng
Juzheng Feng
Edge wave defects occurring during the roll forming process of circular tubes are one of the most common issues in engineering. The aim of this study is to clarify the causes of edge wave formation through numerical simulations and experiments, and to optimize the edge wave defects generated by round pipes. Based on the basic theory of the roll bending process and the actual production conditions, a roll bending forming scheme for a thin-walled circular TA2 pipe is designed. Moreover, a model of the pure TA2 titanium material were established to predict the generation of edge waves in tubes, a finite element model of tube continuous roll forming, and a roll bending experimental platform were established. The accuracy of the finite element model was verified. The results indicate that the longitudinal stress is the main factor affecting edge wave defects. By combining the dual-radius forming method and the uphill forming method, an edge wave control strategy is proposed, which can effectively prevent the formation of edge wave defects. Furthermore, industrial experiments were conducted, which proved that the forming strategy can effectively control the edge wave defects of the circular TA2 tube. The number of edge waves decreased from an average of 4 per meter to 0.