View All Publications
15 March 2023 in ACS Omega
Verified
Journal Article
Open access
LDLongfei Dong
Longfei Dong
XWXiao Wu
Xiao Wu
KLKun Liu
Kun Liu
QSQichen Sun
Qichen Sun
In this study, the results and experimental data under static conditions are verified based on a calculation method. The deviation is controlled within 10%, which verifies the reliability of the experimental data. It is found that pitching has the most obvious influence on heat transfer. Through an analysis of the heat transfer coefficient on the shell side and the friction pressure drop along the path, the variation under rocking conditions is obtained.

24 April 2025 in Case Studies in Thermal Engineering
Verified
Journal Article
Open access
LDLongfei Dong
Longfei Dong
YXYanping Xin
Yanping Xin
XWXiao Wu
Xiao Wu
RZRui Zhang
Rui Zhang

11 December 2023 in PLOS ONE
Verified
Journal Article
Open access
PDF file
LDLongfei Dong
Longfei Dong
CDCongcong Dong
Congcong Dong
XWXiao Wu
Xiao Wu
LNG floating production storage and offloading (FPSO) unit is a new type of floating production unit developed for offshore natural gas fields. It performs the functions of natural gas extraction, pretreatment, liquefaction, and storage. In this study, the heat transfer characteristics of a spiral-wound heat exchanger were studied using numerical simulations, which provides a basis for equipment selection and structural optimization of spiral-wound heat exchangers. The main research contents and conclusions are as follows. Under land-based simulation conditions, the heat transfer coefficient of the shell side of the spiral-wound heat exchanger decreases with an increase in the winding angle of the heat exchange tube, decreases with an increase in the spacing of the heat exchange tube, and increases with an increase in the outer diameter of the heat exchange tube. When the winding angle increased from 5° to 8°, the heat transfer coefficient decreased by 6.70%. The heat transfer coefficient of the shell side decreased by 13.21% when the heat exchange tube spacing increased from 14 to 17 mm. The heat transfer coefficient of the shell side increased by 22.89% when the outer diameter of the heat exchange tube increased from 9 to 12 mm. When the sloshing angle is constant, the heat transfer coefficient of the spiral-wound heat exchanger decreases with an increase in the winding angle and spacing of the heat exchange tubes, and increases with an increase in the outer diameter of the heat exchange tubes. When the structural parameters of the heat exchanger are constant, the heat transfer coefficient decreases as the sloshing angle increases. When the sloshing angle was less than 3°, the sloshing promoted heat transfer on the shell side. When the sloshing angle was higher than 7°, the heat transfer effect of the shell side deteriorated considerably, which weakened the heat transfer performance of the heat exchanger. When the sloshing period is constant, the heat transfer coefficient of the wound heat exchanger decreases with an increase in the winding angle and spacing of the heat exchange tubes, and increases with an increase in the outer diameter of the heat exchange tubes. When the structural parameters of the heat exchanger are constant, the heat transfer coefficient increases with sloshing period. When the sloshing period was greater than 15 s, the influence of sloshing on the heat transfer on the shell side of the heat exchanger was relatively weak.

21 July 2023 in ACS Omega
Verified
Journal Article
Open access
LDLongfei Dong
Longfei Dong
HWHao Wang
Hao Wang
XWXiao Wu
Xiao Wu
YXYanping Xin
Yanping Xin
SJShunyao Jiang
Shunyao Jiang
YHYanling Huo
Yanling Huo
With the development and utilization of offshore liquefied natural gas, it is increasingly important to study the influence of the heat transfer performance of a spiral-wound heat exchanger under sloshing conditions. This study focused on the effects of different sloshing amplitudes and sloshing periods on the heat transfer and pressure drop performance of a heat exchanger. Through experimental research, the results showed that the fluctuation of the UA (U is the heat transfer coefficient; A is the heat exchange area) value first increased and then decreased with an increase in the sloshing amplitude. The UA value increased by 12.92% and decreased by 42.03% compared to the static value at 3 and 9°, respectively. The fluctuation in the UA value first decreased and then increased with an increase in the sloshing period. The UA value decreased by 36.66% and increased by 10.82% slowly compared to the static value when the sloshing period was 6 and 20 s, respectively. Based on this, a mathematical model of heat transfer under the condition of pitch sloshing was established.

8 March 2025 in ACS Omega
Verified
Journal Article
Open access
LDLongfei Dong
Longfei Dong
YXYanping Xin
Yanping Xin
XWXiao Wu
Xiao Wu
Spiral wound heat exchangers are the core equipment for natural gas liquefaction. Their heat transfer performance significantly affects the liquefaction process. This research investigates how varying sloshing amplitudes and periods affect the heat transfer and pressure drop characteristics of a spiral-wound heat exchanger subjected to yawing, heaving, and inclination. The UA value (where U represents the heat transfer coefficient in W·(m2·K)-1 and A denotes the heat exchange area in m2) exhibits an initial increase followed by a decrease as the yawing sloshing amplitude increases. The UA value at a yaw of 3° is 6.23% higher than the static value, while the UA value at a yaw of 9° is 19.53% lower. The fluctuation in the UA value decreases with an increase in the yawing sloshing period. When the sloshing period is 6 s, the UA value decreases by 16.46% compared to the static value. In contrast, when the sloshing period is 20 s, the UA value slowly increases by 4.19%. The UA value decreases with an increase in the amplitude of heaving sloshing. When the inclination starts, the UA value suddenly increases and then gradually decreases with time. Based on these observations, a mathematical model of heat transfer under yawing conditions is established. The heat transfer performance of spiral-wound heat exchanger under sloshing conditions is systematically studied, and the influence mechanism of sloshing on heat transfer efficiency of heat exchanger is revealed, which provides a new research perspective and experimental data for related fields.

8 April 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
LDLongfei Dong
Longfei Dong
RZRui Zhang
Rui Zhang
The liquefied natural gas (LNG) floating production storage and offloading (FPSO) unit is a new type of floating production device developed for the exploitation, pretreatment, liquefaction, and storage of offshore natural gas. In this study, the shell side structure of the spiral-wound heat exchanger is analyzed, and the effects of varying the Reynolds number (Re), tube outer diameter, and number of distributors on the thickness of the shell-side liquid film are investigated. The results show that as the fluid flows down from the distributor, it hits the upper wall of the pipeline and diffuses evenly to both sides, before converging in between the two distributors. In the axial direction, the thickness of the liquid film increases first, reaches the highest at the peak, then decreases, reaches the lowest at the trough, and then increases again, forming a secondary peak at the drop. The thickness of the liquid film changes periodically, and the period is the distance between the two distributors. The thickness of the circumferential liquid film is negatively correlated with the circumferential angle, α. Moreover, the liquid film is thinnest at α = 120°, and is positively correlated with both the liquid mass flow rate and the outer diameter of the tube. The most uniform liquid film thickness is obtained when Re = 1500, the tube outer diameter is 12 mm, and the number of distributors is 6. The results from this study can guide the design of spiral-wound heat exchangers and facilitate their safe and efficient operation in natural gas liquefaction processes.