Kenneth Long

Dr. Kenneth Long

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 April 2013 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
DGDustin Gallegos
Dustin Gallegos
KLKenneth Long
Kenneth Long
HYHojeong Yu
Hojeong Yu
PCPeter P. Clark
Peter P. Clark
YLYixiao Lin
Yixiao Lin
Brian CunninghamBrian Cunningham
Brian Cunningham
Utilizing its integrated camera as a spectrometer, we demonstrate the use of a smartphone as the detection instrument for a label-free photonic crystal biosensor. A custom-designed cradle holds the smartphone in fixed alignment with optical components, allowing for accurate and repeatable measurements of shifts in the resonant wavelength of the sensor. Externally provided broadband light incident upon an entrance pinhole is subsequently collimated and linearly polarized before passing through the biosensor, which resonantly reflects only a narrow band of wavelengths. A diffraction grating spreads the remaining wavelengths over the camera's pixels to display a high resolution transmission spectrum. The photonic crystal biosensor is fabricated on a plastic substrate and attached to a standard glass microscope slide that can easily be removed and replaced within the optical path. A custom software app was developed to convert the camera images into the photonic crystal transmission spectrum in the visible wavelength range, including curve-fitting analysis that computes the photonic crystal resonant wavelength with 0.009 nm accuracy. We demonstrate the functionality of the system through detection of an immobilized protein monolayer, and selective detection of concentration-dependent antibody binding to a functionalized photonic crystal. We envision the capability for an inexpensive, handheld biosensor instrument with web connectivity to enable point-of-care sensing in environments that have not been practical previously.

24 July 2017 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
KLKenneth Long
Kenneth Long
EWElizabeth V. Woodburn
Elizabeth V. Woodburn
HLHuy M. Le
Huy M. Le
USUtsav K. Shah
Utsav K. Shah
SLSteven S. Lumetta
Steven S. Lumetta
Brian CunninghamBrian Cunningham
Brian Cunningham
We demonstrate a smartphone-integrated handheld detection instrument capable of utilizing the internal rear-facing camera as a high-resolution spectrometer for measuring the colorimetric absorption spectrum, fluorescence emission spectrum, and resonant reflection spectrum from a microfluidic cartridge inserted into the measurement light path. Under user selection, the instrument gathers light from either the white “flash” LED of the smartphone or an integrated green laser diode to direct illumination into a liquid test sample or onto a photonic crystal biosensor. Light emerging from each type of assay is gathered via optical fiber and passed through a diffraction grating placed directly over the smartphone camera to generate spectra from the assay when an image is collected. Each sensing modality is associated with a unique configuration of a microfluidic “stick” containing a linear array of liquid chambers that are swiped through the instrument while the smartphone captures video and the software automatically selects spectra representative of each compartment. The system is demonstrated for representative assays in the field of point-of-care (POC) maternal and infant health: an ELISA assay for the fetal fibronectin protein used as an indicator for pre-term birth and a fluorescent assay for phenylalanine as an indicator for phenylketonuria. In each case, the TRI-analyzer is capable of achieving limits of detection that are comparable to those obtained for the same assay measured with a conventional laboratory microplate reader, demonstrating the flexibility of the system to serve as a platform for rapid, simple translation of existing commercially available biosensing assays to a POC setting.

17 October 2019 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
CCCongnyu Che
Congnyu Che
NLNantao Li
Nantao Li
KLKenneth Long
Kenneth Long
MAMiguel Ángel Aguirre
Miguel Ángel Aguirre
TCTaylor D. Canady
Taylor D. Canady
Brian CunninghamBrian Cunningham
Brian Cunningham
We demonstrate a rapid, 2-step, and ultrasensitive assay approach for quantification of target protein molecules from a single droplet test sample. The assay is comprised of antibody-conjugated gold nanoparticles (AuNPs) that are “activated” when they are mixed with the test sample and bind their targets. The resulting liquid is passed through a microfluidic channel with a photonic crystal (PC) biosensor that is functionalized with secondary antibodies to the target biomarker, so that only activated AuNPs are captured. Utilizing recently demonstrated hybrid optical coupling between the plasmon resonance of the AuNP and the resonance of the PC, each captured AuNP efficiently quenches the resonant reflection of the PC, thus enabling the captured AuNPs to be digitally counted with high signal-to-noise. To achieve a 2-step assay process that is performed on a single droplet test sample without washing steps or active pump elements, controlled single-pass flow rate is obtained with an absorbing paper pad waste reservoir embedded in a microfluidic cartridge. We use the activate capture and digital counting (AC + DC) approach to demonstrate HIV-1 capsid antigen p24 detection from a 40 μL spiked-in human serum sample at a one thousand-fold dynamic range (1–103 pg mL−1) with only a 35-minute process that is compatible with point-of-care (POC) analysis. The AC + DC approach allows for ultrasensitive and ultrafast biomolecule detection, with potential applications in infectious disease diagnostics and early stage disease monitoring.

15 June 2019 in IEEE Sensors Journal
Verified
Journal Article
Closed access
EWElizabeth V. Woodburn
Elizabeth V. Woodburn
KLKenneth Long
Kenneth Long
Brian CunninghamBrian Cunningham
Brian Cunningham
We report on the adaptation of a smartphone's rear-facing camera to function as a spectrometer that measures the spectrum of light scattered by common paper-based assay test strips. We utilize a cartridge that enables a linear series of test pads in a single strip to be swiped past the read head of the instrument while the phone's camera records video. The strip is housed in a custom-fabricated cartridge that slides through the instrument to facilitate illumination with white light from the smartphone's flash LED that is directed through an optical fiber. We demonstrate the ability to detect subtle changes in the scattered spectrum that enables quantitative analysis of single-analyte and multi-analyte strips. The demonstrated capability can be applied to broad classes of paper-based assays in which visual observation of colored strips is not sufficiently quantitative, and for which analysis of red-green-blue pixel values of a camera image are not capable of measuring complex scattered spectra.

13 October 2020 in PLOS ONE
Verified
Journal Article
Open access
PDF file
KLKenneth Long
Kenneth Long
EWElizabeth V. Woodburn
Elizabeth V. Woodburn
IBIan C. Berg
Ian C. Berg
VCValerie Chen
Valerie Chen
WSWilliam S. Scott
William S. Scott
During the current SARS-CoV-2 pandemic there is unprecedented demand for personal protective equipment (PPE), especially N95 respirators and surgical masks. The ability of SARS-CoV-2 to be transmitted via respiratory droplets from asymptomatic individuals has necessitated increased usage of both N95 respirators in the healthcare setting and masks (both surgical and homemade) in public spaces. These precautions rely on two fundamental principles of transmission prevention: particle filtration and droplet containment. The former is the focus of NIOSH N95 testing guidelines, and the latter is an FDA guideline for respirators and surgical masks. While studies have investigated droplet containment to provide guidance for homemade mask production, limited work has been done to characterize the filtration efficiency (FE) of materials used in home mask making. In this work, we demonstrate the low-cost (<$300) conversion of standard equipment used to fit-test respirators in hospital and industrial settings into a setup that measures quantitative FEs of materials based on NIOSH N95 guidelines, and subsequently measure FEs of materials found in healthcare and consumer spaces. These materials demonstrate significant variability in filtration characteristics, even for visually similar materials. We demonstrate a FE of 96.49% and pressure drop of 25.4 mmH20 for a double-layer of sterilization wrap used in surgical suites and a FE of 90.37% for a combination of consumer-grade materials. The excellent filtration characteristics of the former demonstrate potential utility for emergent situations when N95 respirators are not available, while those of the latter demonstrate that a high FE can be achieved using publicly available materials.

1 August 2019 in Journal of Pharmaceutical Sciences
Verified
Journal Article
Closed access
MAMiguel Ángel Aguirre
Miguel Ángel Aguirre
KLKenneth Long
Kenneth Long
Brian CunninghamBrian Cunningham
Brian Cunningham