Traditionally, chronic wound infection is diagnosed by visual inspection under white light and microbiological sampling, which are subjective and suboptimal, respectively, thereby delaying diagnosis and treatment. To address this, we developed a novel handheld, fluorescence imaging device (PRODIGI) that enables non-contact, real-time, high-resolution visualization and differentiation of key pathogenic bacteria through their endogenous autofluorescence, as well as connective tissues in wounds. This was a two-part Phase I, single center, non-randomized trial of chronic wound patients (male and female, ≥18 years; UHN REB #09-0015-A for part 1; UHN REB #12-5003 for part 2; clinicaltrials.gov Identifier: NCT01378728 for part 1 and NCT01651845 for part 2). Part 1 (28 patients; 54% diabetic foot ulcers, 46% non-diabetic wounds) established the feasibility of autofluorescence imaging to accurately guide wound sampling, validated against blinded, gold standard swab-based microbiology. Part 2 (12 patients; 83.3% diabetic foot ulcers, 16.7% non-diabetic wounds) established the feasibility of autofluorescence imaging to guide wound treatment and quantitatively assess treatment response. We showed that PRODIGI can be used to guide and improve microbiological sampling and debridement of wounds in situ, enabling diagnosis, treatment guidance and response assessment in patients with chronic wounds. PRODIGI is safe, easy to use and integrates into the clinical workflow. Clinically significant bacterial burden can be detected in seconds, quantitatively tracked over days-to-months and their biodistribution mapped within the wound bed, periphery, and other remote areas. PRODIGI represents a technological advancement in wound sampling and treatment guidance for clinical wound care at the point-of-care. ClinicalTrials.gov NCT01651845; ClinicalTrials.gov NCT01378728
1 November 2005 in Photochemistry and Photobiology
This study was designed to demonstrate that bioluminescence imaging (BLI) can be used as a new tool to evaluate the effects of low‐level laser therapy (LLLT) during in vivo inflammatory process. Here, the efficacy of LLLT in modulating inducible nitric oxide synthase (iNOS) expression using different therapeutic wavelengths was determined using transgenic animals with the luciferase gene under control of the iNOS gene expression. Thirty transgenic mice, FVB/N‐Tg(iNOS‐luc)Xen, were allocated randomly to one of four experimental groups treated with different wavelengths (λ= 635, 785, 808 and 905 nm) or a control group (nontreated). Inflammation was induced by intra‐articular injection of zymosan A in both knee joints. Laser treatment (25 mW cm−2, 200 s, 5 J cm−2) was applied to the knees 15 min after inflammation induction. Measurements of iNOS expression were performed at various times (0, 3, 5, 7, 9 and 24 h) by measuring the bioluminescence signal using a highly sensitive charge‐coupled device (CCD) camera. The results showed a significant increase in BLI signal after irradiation with 635 nm laser when compared to the nonirradiated animals and the other LLLT‐treated groups, indicating wavelength dependence of LLLT effects on iNOS expression during the inflammatory process, and thus demonstrating an action spectrum of iNOS gene expression following LLLT in vivo that can be detected by BLI. Histological analysis was also performed and demonstrated the presence of fewer inflammatory cells in the synovial joints of mice irradiated with 635 nm compared with nonirradiated knee joints.
Risk-stratified screening for breast cancer (BC) is increasingly considered as a promising approach. However, its implementation is challenging and needs to be acceptable to women. We examined Canadian women’s attitudes towards, comfort level about, and willingness to take part in BC risk-stratified screening. We conducted an online survey in women aged 30 to 69 years in four Canadian provinces. In total, 4293 women completed the questionnaire (response rate of 63%). The majority of women (63.5% to 72.8%) expressed favorable attitudes towards BC risk-stratified screening. Most women reported that they would be comfortable providing personal and genetic information for BC risk assessment (61.5% to 67.4%) and showed a willingness to have their BC risk assessed if offered (74.8%). Most women (85.9%) would also accept an increase in screening frequency if they were at higher risk, but fewer (49.3%) would accept a reduction in screening frequency if they were at lower risk. There were few differences by province; however, outcomes varied by age, education level, marital status, income, perceived risk, history of BC, prior mammography, and history of genetic test for BC (all p ≤ 0.01). Risk-based BC screening using multifactorial risk assessment appears to be acceptable to most women. This suggests that the implementation of this approach is likely to be well-supported by Canadian women.
Evidence has emerged for a role of vitamin D in the development of breast cancer, and there is some suggestion that its antiproliferative effect is greater in hormone-receptor-positive cells. Few epidemiologic studies have considered the association between vitamin D and hormone-receptor-defined breast cancer, and the results are conflicting. Considering 759 cases and 1,135 controls from a case-control study (Ontario, Canada, 2003–2005), the authors examined the association between vitamin D intake at specific ages and combined estrogen-receptor- (ER) and progesterone-receptor- (PR) defined breast cancer. While increased intake of vitamin D (from the sun and diet) was most consistently associated with a significantly reduced risk of ER+/PR+ tumors (e.g., odds ratio = 0.76, 95% confidence interval: 0.59, 0.97 for use of cod liver oil during adolescence), comparable nonsignificant associations were found for receptor-negative (ER−/PR−) (odds ratio = 0.74, 95% confidence interval: 0.53, 1.04) and mixed (ER+/PR−) (odds ratio = 0.79, 95% confidence interval: 0.51, 1.22) tumors. This study suggests that vitamin D is associated with a reduced risk of breast cancer regardless of ER/PR status of the tumor. Future studies with a larger number of receptor-negative and mixed tumors are required.
1 May 2008 in Cancer Epidemiology, Biomarkers & Prevention
Transillumination breast spectroscopy (TiBS) uses nonionizing optical radiation to gain information about tissue properties directly from the breast. TiBS measurements were obtained from 225 women with normal mammograms. Principal component analysis was used to reduce the spectral data set into four principal components and to generate four TiBS scores (t1-t4) for each woman. These components and scores represent light scattering, water, lipid, and hemoglobin content. Percent density, dense area, and nondense area were measured using Cumulus. The association between TiBS scores and quantitative mammographic features was analyzed using linear regression stratified by menopausal status and adjusted for body mass index. Among premenopausal women, t1 and t3 were significantly associated with percent density (βt1 = −0.14, P = 0.04; βt3 = −2.43, P < 0.0001), whereas t2 and t3 were significantly associated with dense area (βt2 = −1.57, P < 0.0001; βt3 = −2.54, P < 0.0001). Among postmenopausal women, t1, t3, and t4 were significantly associated with percent density (βt1 = −0.30, P < 0.0001; βt3 = −2.51, P < 0.0001; βt4 = 4.75, P < 0.0001) and dense area (βt1 = −0.19, P = 0.004; βt3 = −2.13, P = 0.002; βt4 = 5.02, P < 0.0001). Scores t2 and t4 were also significantly correlated with age among postmenopausal women (rt2 = 0.41 and rt4 = −0.36). Given the association with quantitative mammographic features and tissue changes related to age and menopause, TiBS scores may prove useful as intermediate markers in studies of breast cancer etiology and prevention. (Cancer Epidemiol Biomarkers Prev 2008;17(5):1043–50)