Exposure to loud noise or chemical agents may cause hearing disorders such as tinnitus and recruitment, known as an increase in the perception of loudness in addition to hearing loss. Our study aims to evaluate the hearing abilities of hairdressers exposed to noise and chemical agents in the working environment. The study included one hundred hairdressers and one hundred participants who do not work as hairdressers or are nonworkers. The participants' demographic characteristics, working conditions, and auditory complaints were questioned, and each participant completed the Speech, Spatial, and Qualities of Hearing Scale (SSQ). A statistically significant difference was found between the two groups in speech perception, spatial perception, hearing quality, and general SSQ scores. Hairdressers' SSQ scores were significantly lower in all sub-dimensions and general scale scores (p < 0.001). The auditory complaints of the hairdressers and the low SSQ scores indicate that exposure to noise and chemical agents affects the hairdressers' hearing system.
26 November 2022 in The Egyptian Journal of Otolaryngology
Geotropic direction-changing positional nystagmus (DCPN) is transient in lateral semicircular canal (LSSK) canalolithiasis; it usually cuts off within a minute and fatigues. However, a “light cupula” mechanism has been described for patients with positional vertigo who exhibit a persistent geotropic DCPN without delay or fatigue. When the cupula becomes lighter than the surrounding endolymph, deflection may occur in the cupula under the influence of gravity. The person experiences dizziness and persistent positional nystagmus can be observed while remaining in that position.In this review, studies investigating the “light cupula phenomenon,” which is a newly defined phenomenon in the literature, were compiled. A systematic literature search was conducted on the light cupula phenomenon in PubMed and Google Scholar databases to illuminate the clinical side of this new phenomenon and reveal its distinctive features. Turkish and English articles published between 2010 and 2021 were scanned; the thesis, reviews, and books were excluded from the study. Forty-eight articles were included in the study.Mechanisms underlying light cupula has been explained as the “heavier endolymph hypothesis” with increased endolymph specific gravity due to an acute attack such as labyrinth hemorrhage, insufficient inner ear perfusion, or inflammation in the inner ear; “lighter cupula hypothesis” based on alcohol acting on the cupula earlier and making it lighter than the endolymph; “light particle hypothesis” due to the buoyancy of light debris, which are degenerative, swollen, and inflammatory cells in the endolymph adhering to the cupula and the “altered endolymph/perilymph density ratio hypothesis” that the difference in density between perilymph and endolymph causes light cupula. The pathophysiology of the light cupula phenomenon is still unclear, but it can be thought that all the different hypotheses may be effective in this phenomenon. Therefore, nystagmus characteristics and clinical course should be considered in patients for a more effective diagnosis and treatment process. In addition, the results of the studies show that light cupula may not be an uncommon disease and that some patients with geotropic DCPN can often be misdiagnosed as canalolithiasis LSCC-BPPV.
15 July 2022 in The Egyptian Journal of Otolaryngology
Background: The acoustic stapedius reflex is formed by the contraction of the stapedius muscle in the middle ear cavity when a loud sound is given to both ears. Changes in properties such as the intensity, frequency, duration, and speed of stimulus affect reflex responses. Methods: As a result of the literature review conducted between 2005 and 2020, 2846 articles were reviewed and 30 articles evaluating the effects of stimulus changes on acoustic reflex responses were included in the study. Main text: In the studies reviewed, it was observed that lower threshold values were obtained by using noise as a stimulus instead of pure sound. Different results were found regarding the duration and frequency of the stimulus. It has been reported that stimulus frequency does not have a significant effect on acoustic reflex delays and the acoustic stapedius reflex threshold increases in the presence of opposite side noise. Conclusion: As a result of the studies reviewed, it was seen that the changes in many properties of the stimulus that activate the middle ear muscles affected the reflex response.
1 January 2025 in Turkiye Klinikleri Journal of Health Sciences
Objective: Mobile hearing test applications allow users to assess their hearing thresholds directly on their personal phones. While numerous studies have evaluated the validity and reliability of these applications, the impact of different mobile phones on test results has not been thoroughly investigated. This study aims to investigate how mobile hearing test results vary based on the mobile phone used. Material and Methods: Air conduction hearing thresholds of 78 participants with normal hearing, aged 18-25 years (20.961.13) were determined with Hearing Test (e-audiologia.pl) and uHear applications in a quiet environment (<30 dBA), on both Android and iOS-based reference phones, as well as the participants' personal mobile phones. The results of the applications on the reference phone and the participants' phones and the results of both applications on the reference phone were compared. Results: The Hearing Test (e-audiologia.pl) thresholds were significantly lower than the uHear at all frequencies bilaterally (p<0.05). 4000-6000 Hz in the right ear and 1000, 4000, and 6000 Hz in the left ear thresholds in the Hearing Test (e-audiologia.pl) were significantly better on the reference phone (p<0.05). Also, in the uHear, hearing thresholds were significantly better on the reference phone at 500, 1000, and 2000 Hz bilaterally and on the participants' phones at 4000 Hz in the left ear (p<0.05). Conclusion: Mobile hearing test applications may yield varying results across different mobile phones. Manufacturers and researchers should account for these device-related variations when designing and evaluating such tests.
19 December 2025 in The Journal of International Advanced Otology
BACKGROUND: Auditory attention, a complex cognitive function crucial for learning and effective communication, plays a vital role in children’s academic and social development. This study aims to develop a rapid, reliable, and age-appropriate assessment tool to evaluate frequency-based auditory attention in children, addressing a current gap in standardized testing for auditory and cognitive processing abilities. METHODS: This study included 40 typically developed children (20 females, 20 males) aged 10-13 years. A frequency-based auditory attention test (FBAAT) was developed using filtered monosyllabic word lists representing low, mid, high, and general frequency ranges. The lists were presented in quiet and in +10 dB signal-to-noise ratio (SNR) background noise conditions. Participants identified pre-defined target words by pressing a button. Test-retest reliability was assessed in a subgroup of participants. RESULTS: The FBAAT was administered to each participant. Gender differences were minimal, with males scoring significantly higher only on the general list in the background noise condition (P = .01). Background noise (+10 dB SNR) significantly reduced performance in the general list compared to the condition without noise (P=.04). General and low-frequency lists yielded better recognition scores than mid- and high-frequency lists (P < .05). However, there were no significant differences between the general and low-frequency lists, nor between the mid- and high-Frequency lists (P > .05). Test-retest reliability analysis indicated no significant differences between initial and retest scores (P > .05), confirming consistency over time. CONCLUSION: Preliminary findings suggest that the Turkish FBAAT is feasible and demonstrates acceptable test-retest reliability in typically developing children; however, further research is needed to validate and generalize these results.