Erin Panczyk

Dr. Erin Panczyk

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 July 2020 in Analytical Chemistry
Verified
Journal Article
Closed access
DSDalton T. Snyder
Dalton T. Snyder
EPErin Panczyk
Erin Panczyk
ASArpad Somogyi
Arpad Somogyi
DKDesmond A. Kaplan
Desmond A. Kaplan
VWVicki H. Wysocki
Vicki H. Wysocki

22 March 2021 in Analytical Chemistry
Verified
Journal Article
Closed access
EPErin Panczyk
Erin Panczyk
DSDalton T. Snyder
Dalton T. Snyder
MRMark E. Ridgeway
Mark E. Ridgeway
ÁSÁrpád Somogyi
Árpád Somogyi
MPMelvin A. Park
Melvin A. Park
VWVicki H. Wysocki
Vicki H. Wysocki

4 October 2019 in Analytical Chemistry
Verified
Journal Article
Closed access
DSDalton T. Snyder
Dalton T. Snyder
EPErin Panczyk
Erin Panczyk
ASAlyssa Q. Stiving
Alyssa Q. Stiving
JGJoshua D. Gilbert
Joshua D. Gilbert
ASArpad Somogyi
Arpad Somogyi
VWVicki Wysocki
Vicki Wysocki


21 June 2024 in Journal of the American Society for Mass Spectrometry
Verified
Journal Article
Closed access
EPErin Panczyk
Erin Panczyk
YLYu-Fu Lin
Yu-Fu Lin
SHSophie R. Harvey
Sophie R. Harvey
DSDalton T. Snyder
Dalton T. Snyder
FLFanny C. Liu
Fanny C. Liu
VWVicki H. Wysocki
Vicki H. Wysocki

21 January 2020 in Analytical Chemistry
Verified
Journal Article
Open access
EPErin Panczyk
Erin Panczyk
JGJoshua D. Gilbert
Joshua D. Gilbert
GJGargi S. Jagdale
Gargi S. Jagdale
ASAlyssa - Alyssa Stiving
Alyssa - Alyssa Stiving
LBLane A. Baker
Lane A. Baker
VWVicki H. Wysocki
Vicki H. Wysocki
The use of submicron capillaries for nanoelectrospray ionization of native proteins and protein complexes effectively reduces the number of nonspecific salt adducts to biological molecules, therefore increasing the apparent resolution of a mass spectrometer without any further instrument modifications or increased ion activation. However, the increased interaction between proteins and the surface of the capillary has been shown to promote protein expansion and therefore loss of native structure. Here, we compare the effect of micron and submicron sized capillaries on the native structures of the protein complexes streptavidin, concanavalin A, and C-reactive protein under charge reducing conditions. We observe that the use of submicron capillaries did not result in a significantly higher charge state distribution, indicative of expansion, when compared to micron sized capillaries for complexes in 100 mM ammonium acetate and 100 mM triethylammonium acetate and for streptavidin in 200 mM ammonium acetate with no charge reduction. Additionally, no significant differences in collision cross sections were observed using ion mobility mass spectrometry. Finally, the dissociation behavior of protein complexes ionized using micron and submicron capillaries were compared to determine if any structural perturbation occurred during ionization. Protein complexes from both capillary sizes displayed similar surface-induced dissociation patterns at similar activation energies. The results suggest that submicron capillaries do not result in significant changes to protein complex structure under charge reducing conditions and may be used for native mass spectrometry experiments. Submicron capillaries can be used to resolve small mass differences of biological systems on a QTOF platform, however, a laser tip puller is required for pulling reproducible submicron capillaries and disruption in spray due to clogging was observed for larger protein complexes.