Objectives: This study investigated the prevalence of feline chronic gingivostomatitis in urban feral cats in South Korea and analysed its risk factors. Methods: Three hundred and forty-five feral cats that visited the hospital for neutering using a trap–neuter–return approach were screened for feline chronic gingivostomatitis based on clinical criteria. In addition, we determined if body weight, sex and the presence of tongue lesions are risk factors for feline chronic gingivostomatitis. The difference in severity due to the presence or absence of risk factors, and the relationship between gross findings and histopathological lesions, were analysed by grading lesion severity. Results: Feline chronic gingivostomatitis was diagnosed in 92 cats. Disease prevalence did not significantly differ with body weight and sex but was significantly related to tongue lesions. Conclusions and relevance: The prevalence of feline chronic gingivostomatitis in urban feral cats in South Korea was 26.6%. It was significantly more prevalent in cats that had tongue lesions. Severity was also significantly associated with tongue lesions. Feline chronic gingivostomatitis may be associated with an infectious agent that causes tongue lesions.
16 May 2020 in Journal of Biomedical Materials Research Part A
When using a pulsatile left ventricular assist device (LVAD), it is important to reduce the cardiac load variations of the native heart because severe cardiac load variations can induce ventricular arrhythmia. In this study, we investigated the effect of counter-pulsation control of the LVAD on the reduction of cardiac load variation. A ventricular electrocardiogram-based counter-pulsation control algorithm for a LVAD was implemented, and the effects of counter-pulsation control of the LVAD on the reduction of the working load variations of the left ventricle were determined in three animal experiments. Deviations of the working load of the left ventricle were reduced by 51.3%, 67.9%, and 71.5% in each case, and the beat-to-beat variation rates in the working load were reduced by 84.8%, 82.7%, and 88.2% in each ease after counter-pulsation control. There were 3 to 12 premature ventricle contractions (PVCs) before counter-pulsation control, but no PVCs were observed during counter-pulsation control. Counter-pulsation control of the pulsatile LVAD can reduce severe cardiac load variations, but the average working load is not markedly affected by application of counter-pulsation control because it is also influenced by temporary cardiac outflow variations. We believe that counter-pulsation control of the LVAD can improve the long-term safety of heart failure patients equipped with LVADs.