The development of an optical clock with ultimate accuracy and stability requires lasers with very narrow linewidths. We present two ultrastable laser systems based on 48-cm-long Fabry–Perot cavities made of ultralow expansion glass in horizontal and vertical configurations operating at 698 nm. Fractional frequency instability of the beat signal between the two lasers reaches at the averaging time of 1 s. We experimentally characterized the contribution of the different noise sources (power fluctuations, residual amplitude modulation, the Doppler noise, and sensitivity to the shock impact) and found that in our case the laser frequency instability to a large extent is determined by an optoelectronic feedback loop. Although the vertical configuration was easier to manufacture and transport, it is much more sensitive to acoustics and horizontal accelerations compared to the horizontal one. Both laser systems were transported over a 60 km distance from the Lebedev Physical Institute to the All-Russian Scientific Research Institute for Physical-Engineering and Radiotechnical Metrology (VNIIFTRI), where they serve as local oscillators for spectroscopy of the clock transition in the recently developed strontium optical clock.
We present a novel technique for in-vacuum cavity-enhanced UV spectroscopy that allows nearly continuous measurements over several days, minimizing mirror degradation caused by high-power UV radiation. Our method relies on pulsing of the cavity’s internal power, which increases the UV intensity to maximum only for short periods when the studied atom is within the cavity mode volume while keeping the average power low to prevent mirror degradation. Additionally, this method significantly decreases laser-induced background on charged particle detectors. The described 244 nm laser system is designed for 1S-2S two-photon CW spectroscopy of muonium in the Mu-MASS project. It was tested to provide intracavity powers above 20 W, requiring maintenance only a few times a day. The pulsing technique demonstrates minimal impact on the radiation frequency, with no observed shifts exceeding 15 kHz. Our approach represents a promising new technique for high-precision spectroscopy of atoms in harsh UV environments and demonstrates the feasibility of CW spectroscopy of muonium.
An optical frequency transfer at a wavelength of 1542 nm via an ultra-stable 5-m free-space link with active compensation of the phase noise caused by atmospheric fluctuations is demonstrated. The link-induced phase noise and its contribution to the frequency transfer instability are investigated. It is shown that, with the phase compensation system switched on, the link contribution to the relative transfer instability in terms of Allan deviation reaches 1.7 × 10−19 for a 5000-s averaging time.
1 September 2020 in Bulletin of the Lebedev Physics Institute
Two ultrastable laser systems for the clock transition spectroscopy in the strontium frequency standard are developed. The high stability of laser radiatio
We propose a method for thermal expansion compensation of reference monolithic optical cavities for laser frequency stabilization. Two schemes of optical cavities are considered: a Fabry–Perot interferometer with a crimp ring and a whispering-gallery-mode cavity with a clamp. In each scheme, thermal expansion compensation is achieved due to the strained connection of the cavity with an element made of a material with a high coefficient of thermal expansion. The temperature range of the cavities’ optical length stabilization is estimated.
Qubit systems based on trapped ultracold ions win one of the leading positions in the quantum computing field, demonstrating quantum algorithms with the highest complexity to date. Surface Paul traps for ion confinement open the opportunity to scale quantum processors to hundreds of qubits and enable high-connectivity manipulations on ions. To fabricate such a system with certain characteristics, the special design of a surface electrode structure is required. The depth of the trapping potential, the stability parameter, the secular frequency and the distance between an ion and the trap surface should be optimized for better performance. Here, we present the optimized design of a relatively simple surface trap that allows several important high-fidelity primitives: tight ion confinement, laser cooling, and wide optical access. The suggested trap design also allows us to perform an important basic operation, namely, splitting an ion chain into two parts.