Jeongwon Hwang

Ms. Jeongwon Hwang

orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2000 in Japanese Journal of Applied Physics
Verified
Journal Article
Closed access
Dae-Shik SeoDae-Shik Seo
Dae-Shik Seo
JHJeongwon Hwang
Jeongwon Hwang
The effects of liquid-crystal (LC) alignment and electro-optical (EO) characteristics of photoaligned twisted-nematic (TN)-LC display (LCD) on a PMCh (poly (4′-methacryloyloxy chalcone)) surface using a new photodimerization method were investigated. Photopolymer layers were exposed by linearly polarized UV during heating at 100°C. Excellent voltage-transmittance (V-T) of photodimerized TN-LCD on the PMCh surface for 1 min using the new photodimerization method was observed. The voltage-holding ratio (VHR) of the photodimerized TN-LCD on the PMCh surface using the new photodimerization method is higher than that of the conventional photodimerization method. We suggest that the new photodimerization method for LC aligning is the most promising rubbing-free technique.

1 November 2024 in Journal of Electronic Imaging
Verified
Journal Article
Closed access
PDF file
SKSeunghyun Kim
Seunghyun Kim
KLKunyoung Lee
Kunyoung Lee
JHJeongwon Hwang
Jeongwon Hwang
HLhakjin lee
hakjin lee
ELEui Chul Lee
Eui Chul Lee
This study investigates the enhancement of remote photoplethysmography (rPPG) using a hybrid system that integrates RGB and near-infrared (NIR) cameras. rPPG, a non-contact method for heart rate (HR) measurement, relies on analyzing subtle color changes in facial videos. We compare traditional signal processing methods, such as independent component analysis and principal component analysis, with advanced deep learning models such as DeepPhys and PhysFormer. Traditional methods often struggle with lighting variations and motion artifacts, whereas deep learning approaches demonstrate improved robustness and accuracy. Our hybrid approach leverages the strengths of both RGB and NIR cameras, addressing their individual limitations. We propose two methods, the first is a four-channel method, which overlays RGB and NIR frames to create a four-channel image, and the second is an ensemble method, which applies weights to the tokens extracted from each video and then sums them. These hybrid approaches significantly enhance performance, achieving higher percentage of time with error within 6 BPM (PTE6) scores across various scenarios, including still conditions and motion environments. PTE6 represents the proportion of the entire timeline where the predicted HR is within six beats per minute (BPM) of the actual HR and is a commonly used metric in HR prediction studies. For example, the four-channel method achieved a PTE6 score of 72.89% in still conditions and 56.73% in motion scenarios, outperforming the single-camera setups. Specifically, the RGB camera achieved 70.97% and the NIR camera 67.89% in still conditions, whereas in motion scenarios, the RGB camera scored 53.24% and the NIR camera 37.99%. These findings highlight the potential of combining RGB and NIR cameras to improve the accuracy and reliability of rPPG. This approach opens new avenues for advanced telemedicine applications, providing a robust solution for continuous health monitoring in diverse environments.

5 July 2025 in Machine Vision and Applications
Verified
Journal Article
Closed access
PDF file
YPYeongje Park
Yeongje Park
JHJeongwon Hwang
Jeongwon Hwang
SJSeungmin Jeong
Seungmin Jeong
ELEui Chul Lee
Eui Chul Lee