Yonggang Wang

Mr. Yonggang Wang


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 June 2025 in Buildings
Verified
Journal Article
Open access
PDF file
HZHong Zhang
Hong Zhang
QLQiuliang Long
Qiuliang Long
Fengqi GuoFengqi Guo
Fengqi Guo
ZSZhaolong Shen
Zhaolong Shen
XCXu Chen
Xu Chen
YWYonggang Wang
Yonggang Wang
The traditional finite element method deals with the temperature field around the cooling tube due to the computational efficiency problems caused by grid division and the uncertainty of the convective heat transfer coefficient, resulting in inaccurate calculation results around the cooling tube. We conducted experiments to study the thermal stress and temperature gradient caused by various factors such as different materials of cooling pipes, pipe diameters, cooling water temperatures, and flow rates. The results showed that aluminum alloy pipes had the highest cooling efficiency but also produced a large temperature gradient. Pipe diameter had the most significant impact on cooling efficiency. Additionally, it is recommended that the cooling water flow velocity is not less than 0.6 m/s to achieve the best efficiency for the cooling pipe of any pipe diameter. The influence range of the cooling pipe on concrete could vary with pipe material, flow rate, and ambient factors. Our experimental results were compared with other heat transfer formulas (the Dittus–Boelter formula and the Yang Joo-Kyoung formula). According to the measured results, the formula is modified). The modified formula can estimate the heat transfer coefficient more accurately according to the flow rate and pipeline characteristics. Finally, the applicability of the formula is further verified by comparing the concrete on the bottom plate of a dam. The proposed heat transfer prediction model can estimate the heat transfer coefficient according to the flow rate and pipeline characteristics, The accuracy of the convection coefficient under different working conditions is improved by 10–25%. It is convenient to predict concrete temperature in practical engineering.

29 May 2025 in Buildings
Verified
Journal Article
Open access
PDF file
HZHong Zhang
Hong Zhang
CWChangxing Wu
Changxing Wu
WLWenlong Liu
Wenlong Liu
SWShiqi Wei
Shiqi Wei
YWYonggang Wang
Yonggang Wang
The monorail tourism transit system (MTTS) is a large-scale amusement facility. Currently, there is limited theoretical research on the vehicle–bridge coupling vibration and dynamic amplification factor (DAFs) of this system. The values specified in relevant standards are not entirely reasonable; for instance, the calculated value of the DAFs in the “Large-scale amusement device safety code (GB 8408-2018)” only takes speed into account and is set at 0.44 when the speed is between 20 and 40 km/h. This is overly simplistic and obviously too large. This paper aims to establish a reasonable expression of the DAFs for the MTTS and improve the design code of the industry. Firstly, using on-site trials of the project and the dynamics numerical simulation method, the dynamic response characteristics of the MTTS and the influencing factors of the DAFs were systematically analyzed. The rationality and accuracy of the model were verified. Secondly, combined with the joint simulation model, the dynamic influence mechanism of multifactor coupling on the DAFs was revealed. On this basis, the key regression parameters were selected by using the Pearson correlation coefficient method and the random forest algorithm, and the DAFs prediction model was constructed based on the least absolute shrinkage and selection operator (LASSO) regression theory. Finally, through cross-comparison of simulation data and specification verification, a recommended calculation expression of the DAFs for the MTTS was proposed. The research results show that the established prediction model can predict 94.50% of the variation information of the DAFs of the MTTS and pass the 95% confidence level and 0.05 significance test. The accuracy is high and relatively reasonable and can provide a reference for the design of the MTTS.