Moritz Wiehe

Dr. Moritz Wiehe

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 December 2020 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Open access
MWMoritz Wiehe
Moritz Wiehe
MGMarcos Fernandez Garcia
Marcos Fernandez Garcia
Michael MollMichael Moll
Michael Moll
RMRaul Montero
Raul Montero
FPF. R. Palomo
F. R. Palomo
PPPere Perez-Millan
Pere Perez-Millan
The Transient Current Technique (TCT) is widely used in the field of silicon particle detector development. So far, only laser wavelengths with a photon energy larger than or similar to the silicon band-gap (single photon absorption) were used. Recently, measurements using two photon absorption for silicon detector testing have been carried out for the first time. Excess carriers are only created at the focal point of the laser beam and thus, resolution in all three spatial directions could be achieved. The resolution perpendicular to the incident laser beam could be increased roughly by a factor of ten. First measurements using this new method were performed at the Singular Laser Facility of UPV/EHU. Following the initial success of the method, a compact Two Photon Absorption -Transient Current Technique (TPA-TCT) setup is under development. A first description of the setup and laser system is presented in this article.

11 July 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Open access
SPS. Pape
S. Pape
ECE. Currás
E. Currás
MGM. Fernández García
M. Fernández García
Michael MollMichael Moll
Michael Moll
RMR. Montero
R. Montero
CQC. Quintana
C. Quintana

22 August 2024 in Sensors
Verified
Journal Article
Open access
PDF file
SPSebastian Pape
Sebastian Pape
MGMarcos Fernández García
Marcos Fernández García
Michael MollMichael Moll
Michael Moll
MWMoritz Wiehe
Moritz Wiehe
The Two-Photon Absorption–Transient Current Technique (TPA-TCT) is a device characterisation technique that enables three-dimensional spatial resolution. Laser light in the quadratic absorption regime is employed to generate excess charge carriers only in a small volume around the focal spot. The drift of the excess charge carriers is studied to obtain information about the device under test. Neutron-, proton-, and gamma-irradiated p-type pad silicon detectors up to equivalent fluences of about 7 × 1015 neq/cm2 and a dose of 186 Mrad are investigated to study irradiation-induced effects on the TPA-TCT. Neutron and proton irradiation lead to additional linear absorption, which does not occur in gamma-irradiated detectors. The additional absorption is related to cluster damage, and the absorption scales according to the non-ionising energy loss. The influence of irradiation on the two-photon absorption coefficient is investigated, as well as potential laser beam depletion by the irradiation-induced linear absorption. Further, the electric field in neutron- and proton-irradiated pad detectors at an equivalent fluence of about 7 × 1015 neq/cm2 is investigated, where the space charge of the proton-irradiated devices appears inverted compared to the neutron-irradiated device.

26 July 2025 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Open access
AHAnja Himmerlich
Anja Himmerlich
NCNúria Castelló-Mor
Núria Castelló-Mor
ECEsteban Currás-Rivera
Esteban Currás-Rivera
YGYana Gurimskaya
Yana Gurimskaya
IMIsidre Mateu
Isidre Mateu
JSJoern Schwandt
Joern Schwandt

1 July 2025 in Journal of Instrumentation
Verified
Journal Article
Open access
NSNiels G. Sorgenfrei
Niels G. Sorgenfrei
EAElias Arnqvist
Elias Arnqvist
YGYana Gurimskaya
Yana Gurimskaya
Michael MollMichael Moll
Michael Moll
UPUlrich Parzefall
Ulrich Parzefall
MWMoritz Wiehe
Moritz Wiehe
Future hadron collider experiments will require sensing materials that withstand stronger radiation fields. Therefore, either a frequent replacement of detectors, a significant increase in radiation hardness of Silicon, or a shift to different materials is needed. Wide-bandgap materials are a natural choice, due to their significantly reduced leakage currents, even after irradiation. In recent years, substantial progress in the production of high-quality monocrystalline Silicon Carbide of the 4H polytype has led to a renewed interest in this material. In this article, a study of electrically active defects in a n-type epitaxial 4H Silicon Carbide diode is presented. By employing spectroscopical measurement methods, like Deep-Level Transient Spectroscopy (DLTS) and Thermally Stimulated Currents (TSC), energy levels in the bandgap are investigated. Defect parameters like concentration, activation energy and capture cross-section are stated. A simulation framework was utilised to compare and match the results from the two methods. This study is made in the context of a study of radiation hardness of 4H Silicon Carbide sensors. Other studies investigating macroscopic properties of the material, like their charge collection efficiency after irradiation, were performed on the same kind of diodes. This study provides a first set of measured defect parameters in state-of-the-art 4H-SiC material, from defects present prior to irradiation. These defects are intrinsic, such as vacancies, related to impurities and doping imperfections, or are growth related. The Z 1/2 defect and a Nitrogen related defect were identified.

24 June 2025 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Open access
VKVeronika Kraus
Veronika Kraus
MBMargarita Biveinytė
Margarita Biveinytė
MGMarcos Fernandez Garcia
Marcos Fernandez Garcia
SHSalvador Hidalgo
Salvador Hidalgo
Michael MollMichael Moll
Michael Moll
MWMoritz Wiehe
Moritz Wiehe